York 48 Cooling Capacities 5 TON BCH060, Indoor 85 F 95 F Coil Total, 2500 2250 2000 1750 1500

Page 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036-21564-002-A-0404

COOLING CAPACITIES - 5 TON (BCH060)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air On

 

 

 

 

 

 

Temperature of Air on Outdoor Coil

 

 

 

 

 

 

 

 

 

Indoor

 

 

 

85 °F

 

 

 

 

 

 

 

 

 

 

95 °F

 

 

 

 

 

 

Coil

 

Total

Power

 

Sensible Capacity1, MBH

 

Total

Power

 

 

Sensible Capacity1, MBH

 

 

 

CFM

 

WB

Cap.1

Input2

 

Entering Dry Bulb, °F

 

Cap.1

Input2

 

 

Entering Dry Bulb, °F

 

 

 

 

°F

MBH

KW

86

83

80

77

 

74

71

 

68

MBH

KW

 

86

83

80

77

74

71

68

 

 

 

 

 

 

 

 

 

 

 

72

68

5.7

51

44

38

31

 

-

-

 

-

67

6.0

 

51

45

38

31

-

-

-

 

2500

 

67

65

5.6

58

56

50

43

 

37

30

 

-

64

5.9

 

56

56

50

43

37

30

-

 

 

62

61

5.6

61

61

59

53

 

46

39

 

33

59

5.9

 

59

59

57

50

44

38

31

 

 

 

 

 

 

 

 

 

 

 

57

60

5.5

60

60

59

53

 

47

40

 

33

58

5.8

 

58

58

57

51

44

39

32

 

 

 

 

72

67

5.6

48

42

36

30

 

-

-

 

-

66

5.9

 

48

42

36

30

-

-

-

 

2250

 

67

64

5.6

57

54

48

42

 

36

30

 

-

63

5.9

 

55

54

48

42

35

29

-

 

 

62

60

5.5

60

60

57

51

 

45

39

 

33

57

5.8

 

57

57

55

50

44

38

32

 

 

 

 

 

 

 

 

 

 

 

57

59

5.5

59

59

58

52

 

46

40

 

34

57

5.8

 

57

57

56

50

45

39

33

 

 

 

 

72

66

5.6

45

40

34

29

 

-

-

 

-

65

5.9

 

45

40

34

29

-

-

-

 

 

2000

 

67

63

5.5

56

51

45

40

 

35

29

 

-

61

5.9

 

55

51

45

40

34

29

-

 

 

 

62

59

5.4

59

59

55

50

 

44

39

 

33

56

5.8

 

56

56

54

49

44

38

33

 

 

 

 

 

 

 

 

 

 

 

57

58

5.4

58

58

57

52

 

46

41

 

36

56

5.7

 

56

56

55

50

44

39

34

 

 

 

 

72

64

5.5

42

37

32

27

 

-

-

 

-

62

5.9

 

43

38

33

28

-

-

-

 

1750

 

67

61

5.5

52

47

42

37

 

33

28

 

-

59

5.8

 

53

48

44

39

34

29

-

 

 

62

57

5.4

57

56

51

46

 

41

37

 

32

54

5.7

 

54

54

52

48

43

38

33

 

 

 

 

 

 

 

 

 

 

 

57

57

5.4

57

57

53

48

 

44

39

 

34

54

5.7

 

54

54

53

49

43

39

34

 

 

 

 

72

62

5.5

38

34

30

25

 

-

-

 

-

60

5.8

 

41

36

32

28

-

-

-

 

1500

 

67

59

5.5

48

43

39

35

 

31

26

 

-

57

5.8

 

51

46

42

38

34

29

-

 

 

62

55

5.4

55

52

47

43

 

39

35

 

30

52

5.7

 

52

52

50

46

42

38

34

 

 

 

 

 

 

 

 

 

 

 

57

55

5.3

55

54

49

45

 

41

37

 

32

52

5.6

 

52

52

51

47

42

39

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air On

 

 

 

 

 

 

Temperature of Air on Outdoor Coil

 

 

 

 

 

 

 

 

 

Indoor

 

 

 

105 °F

 

 

 

 

 

 

 

 

 

 

115 °F

 

 

 

 

 

 

Coil

 

Total

Power

 

Sensible Capacity1, MBH

 

Total

Power

 

 

Sensible Capacity1, MBH

 

 

 

CFM

 

WB

Cap.1

Input2

 

Entering Dry Bulb, °F

 

Cap.1

Input2

 

 

Entering Dry Bulb, °F

 

 

 

 

°F

MBH

KW

86

83

80

77

 

74

71

 

68

MBH

KW

 

86

83

80

77

74

71

68

 

 

 

 

 

 

 

 

 

 

 

72

64

6.0

51

44

38

31

 

-

-

 

-

60

6.9

 

50

43

37

30

-

-

-

 

2500

 

67

59

5.9

51

51

49

42

 

36

29

 

-

54

6.6

 

54

53

47

41

34

27

-

 

 

62

54

5.9

54

54

51

46

 

40

33

 

26

49

6.5

 

49

49

48

42

35

28

22

 

 

 

 

 

 

 

 

 

 

 

57

54

5.8

54

54

52

46

 

41

33

 

26

49

6.5

 

49

49

49

43

35

28

23

 

 

 

 

72

63

5.9

48

42

36

30

 

-

-

 

-

60

6.8

 

47

41

35

29

-

-

-

 

2250

 

67

58

5.9

51

51

46

40

 

34

28

 

-

54

6.6

 

47

47

45

39

32

26

-

 

 

62

53

5.8

53

53

52

46

 

40

34

 

28

49

6.5

 

49

49

47

42

36

30

24

 

 

 

 

 

 

 

 

 

 

 

57

53

5.8

53

53

52

46

 

41

35

 

27

49

6.4

 

49

49

48

43

37

31

25

 

 

 

 

72

62

5.9

45

39

34

28

 

-

-

 

-

59

6.8

 

44

38

33

27

-

-

-

 

2000

 

67

57

5.9

51

49

44

38

 

33

27

 

-

53

6.5

 

45

45

42

36

31

26

-

 

 

62

52

5.8

52

52

51

46

 

40

35

 

30

48

6.4

 

48

48

46

42

36

31

25

 

 

 

 

 

 

 

 

 

 

 

57

52

5.7

52

52

51

46

 

40

36

 

31

47

6.4

 

47

47

46

43

36

32

25

 

 

 

 

72

60

5.9

41

37

32

27

 

-

-

 

-

56

6.7

 

40

35

30

25

-

-

-

 

1750

 

67

55

5.8

48

46

41

36

 

31

26

 

-

51

6.5

 

43

43

38

33

29

24

-

 

 

62

50

5.7

50

50

48

43

 

39

34

 

29

46

6.4

 

46

46

43

38

33

28

24

 

 

 

 

 

 

 

 

 

 

 

57

50

5.7

50

50

48

43

 

39

34

 

30

45

6.3

 

45

45

43

38

33

28

25

 

 

 

 

72

57

5.8

38

34

30

25

 

-

-

 

-

53

6.6

 

36

31

27

23

-

-

-

 

1500

 

67

53

5.8

47

43

38

34

 

30

26

 

-

48

6.4

 

41

39

35

30

26

22

-

 

 

62

48

5.7

48

48

45

41

 

37

32

 

28

44

6.3

 

44

44

39

35

30

26

22

 

 

 

 

 

 

 

 

 

 

 

57

48

5.6

48

48

45

41

 

38

32

 

28

43

6.2

 

43

43

40

36

30

26

23

 

1These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit.

2These ratings include the compressor and the outdoor fan motors but not the supply air blower motor. The total outdoor fan motor power input is 0.35 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor.

NOMINAL RATING

ALL SENSIBLE CAPACITY

6

Unitary Products Group

Image 6
Contents Single Package AIR-TO-AIR Heat Pumps FeaturesDescription 036-21564-002-A-0404Features Contd Table of ContentsPhysical Data Basic Units Sound Power RatingsRatings Capacity RatingsCooling Capacities 3 TON BCH036 Cooling Capacities 4 TON BCH048 2500 2250 2000 1750 1500 Air On Cooling Capacities 5 TON BCH060Indoor 85 F 95 F Coil Total Indoor 105 F 115 F Coil TotalCFM RET. AIR CAP Outdoor AIR TEMPERATURE, F 72% RH MBH Heating CapacitiesModel AIR Flow BCH CFM RPMModel Motor BCH Speed CFMMED Static Resistances Heater / CFM LimitationsBlower Circuit Size Breaker BCH PLY Motor Ampacity MIN MAX RLA LRA FLA AmpsSize Number Motor Amps Ampacity Breaker FLA MIN MAX RLA LRA FLA Amps208-1-60 2CE04501025 38.3 2CE04500525 19.12CE04500725 27.1 100 2CE04501525Direct-Drive Units Control WiringPower Wiring Knockout Hole Size Used forDetail a Unit Dimensions CONTD. BCH 3, 4 & 5 TONRear View Unit with Economizer RainhoodRoof Curb Dimensions Component Weights and Center of GravityCenter of Gravity Factory Installed Options FIELD--INSTALLED AccessoriesTypical ROOF-TOP Installation Typical ApplicationsMechanical Specifications Electric Heating Section Unit Operating CharacteristicsOther PRE--ENGINEERED Accessories Available Electrical RequirementsOther Factory Installed Options 036-21564-002-A-0404 Unitary Products Group
Related manuals
Manual 44 pages 16.54 Kb

B6CH 048, B5CH 036, B3CH 036, 48, 60 specifications

York 36, 48, and 60 are three distinct models from the York line of heating, ventilation, and air conditioning (HVAC) systems, specifically designed to meet various commercial and residential needs. Each model fits specific sizing and efficiency requirements while employing advanced technologies to enhance performance.

The York 36 model is ideal for smaller spaces or residential applications. This unit boasts a compact design that integrates seamlessly into tight locations while offering substantial energy efficiency. With a cooling capacity of approximately 36,000 BTU, it’s suitable for apartments or small commercial areas. The use of scroll compressors in this model contributes to reliable operation and quieter performance. Additionally, it utilizes environmentally friendly refrigerants that comply with modern environmental regulations, making it a sustainable choice.

The York 48 model steps up its capabilities for larger residential and commercial buildings. It provides ample cooling capacity at around 48,000 BTU, accommodating medium-sized spaces effectively. One of the standout features is its two-stage cooling technology, which allows for consistent temperature control without excessive energy consumption. This model is equipped with variable speed blowers that optimize airflow, ensuring a comfortable indoor environment even during peak summer months. The York 48 is also engineered with advanced diagnostics, allowing technicians to identify and resolve issues quickly, further enhancing reliability.

Finally, the York 60 model caters to extensive commercial applications with its impressive cooling capacity of approximately 60,000 BTU. This unit excels in large offices, retail spaces, and industrial settings. It employs advanced inverter technology, which adjusts compressor speed based on demand, leading to remarkable energy efficiency and significant cost savings in long-term operation. The York 60 also features robust insulation and weather-tight cabinet design to minimize energy loss. Additionally, its user-friendly interface allows for easy control and monitoring, ensuring optimal performance.

All three York models come equipped with state-of-the-art filters and air purifiers, improving indoor air quality by effectively reducing allergens and pollutants. With a focus on durability, energy efficiency, and advanced technology, York 36, 48, and 60 units represent versatile solutions for their respective applications, demonstrating York's commitment to innovation and sustainability in HVAC systems. Whether for a small apartment or a large commercial space, these units offer reliable comfort and performance tailored to specific needs.