United States Stove 1537Q owner manual Rules for safe installation and operation

Page 4

rules for safe installation and operation

Read these rules and the instructions carefully. Failure to follow them will cause a hazard that could result in death, serious bodily injury, and/or property damage.

1.Check your local codes. This installation must comply with their rulings.

2.Do not install this furnace in a mobile home or trailer.

3.Always connect this furnace to a chimney and vent to the outside. Never vent to another room or inside a building.

4.Do not connect this furnace to an aluminum Type B gas vent. This is not safe and is prohibited by the National Fire Protection Association Code. This furnace requires a masonry or listed factory built chimney for residential type or building heating appliance chimney. Use a 6" diameter chimney or larger, that is high enough to give a good draft. (See Page 8)

5.Be sure that if a masonry chimney is used, it is safely constructed and in good repair. Have the chimney inspected by the Fire Department or an inspector.

6.Inspect chimney connector and chimney before and frequently during the heating season for any deposit of creosote or soot which must be removed (see Chimney Maintenance, page 21.)

7.Provide air for combustion into the room where the furnace is located. If the intake is not in the same room, air must have free access to the room.

8.CAST IRON PARTS MUST BE "SEASONED" TO AVOID CRACKING. BUILD ONLY SMALL FIRES ON FIRST USE.

9.To prevent injury, do not allow anyone to use this furnace who is unfamiliar with the correct operation of the furnace.

10.For further information on using your furnace safely, obtain a copy of the National Fire Protection Association (NFPA) publication "Chimney's, Fireplaces and Solid Fuel Burning Appliances" NFPA 211. The address of the NFPA is Batterymarch Park, Quincy, MA 02269.

11.Keep the ashpit section free of excess ashes. Do not allow ashes to stack higher than the sides of the ash pan.

12.DISPOSAL OF ASHES - Place ashes in a metal container with a tight fitting lid. Keep the closed container on a noncombustible floor or on the ground, well away from all combustible materials. Keep the ashes in the closed container until all cinders have thoroughly cooled. The ashes may be buried in the ground or picked up be a refuse collector.

13.CAUTION - The special paints used on your furnace may give off some smoke while they are curing during first few fires. Build small fires at first. The metal used in construction of the furnace and duct work has a light coating of oil. This could give off smoke and/or odors from registers when furnace is used for the first time. This should disappear after a short period of time. Once this burn-off has occurred, it should not reoccur.

14.CARING FOR PAINTED PARTS - This furnace has a painted outside jacket, which is durable but it will not stand rough handling or abuse. When installing you furnace, use care in handling. Clean with soap and warm water when furnace is not hot. DO NOT use any acids or scouring soap, as these wear and dull the finish. DISCOLORATION WILL OCCUR IF THE FURNACE IS OVERFIRED. FOLLOW OPERATING INSTRUCTIONS CAREFULLY.

15.Keep the feed and ash doors closed at all times except while tending the furnace.

Your Furnace is designed to be installed in a parallel air flow arrangement with a gas or oil-fired forced air upflow-type central furnace, or it may be installed as a central furnace.

4

Image 4
Contents Model 1537Q Congratulations Tools and materials neededSeals Regularly to EN Draft Inducer if USED, is Espe Rules for safe installation and operation HOW the Furnace Functions Model 1537Q Dimensions Locating the Furnace OptionalChimney connection Masonry ChimneyRules for Connector Pipe Installation Adjusting Barometric Draft RegulatorAssembly of Furnace Blower & Component Assembly FIG Model 1537Q Wiring Diagram FIG Room Thermostat 24 VoltInstallation Power Failure Instructions Central Installation U. S. & Canada Add-On Installation U. S. Only Series Installation Wiring Diagram FIG Operating instructions Page Service hints Chimney maintenance11DIK Draft Induced KIT Model 1537Q Parts Model 1537Q Parts List Appendix Installation B Installation C Installation E Installation F Installation H Trouble Shooting Tips for Warm Air Furnace Page Ussc

1537Q specifications

The United States Stove 1537Q is a highly regarded heating solution that merges classic design with modern technology. Known for its efficient heating capabilities, this stove is an excellent choice for homeowners seeking a reliable source of warmth in their living spaces. With a focus on user-friendly features, sturdiness, and aesthetic appeal, the 1537Q has made a name for itself in the market.

One of the standout features of the United States Stove 1537Q is its direct vent technology, which allows for enhanced efficiency by utilizing outside air for combustion. This not only improves energy efficiency but also keeps indoor air quality intact by minimizing drafts. The dual-fuel capability of the 1537Q offers further versatility, allowing users to operate the stove using either propane or natural gas. This flexibility ensures that homeowners can choose the fuel source that best suits their needs.

The stove's heating efficiency is remarkable, with the ability to generate substantial heat while consuming minimal fuel. This is crucial for those looking to reduce energy costs while maintaining a comfortable environment. The 1537Q can heat spaces of up to 1,500 square feet, making it suitable for both large and smaller rooms. The integrated thermostat control allows users to maintain their desired temperature effortlessly.

In terms of design, the United States Stove 1537Q features a classic cast iron construction, which not only enhances durability but also adds aesthetic charm to any room. The large viewing window provides a welcoming glimpse of the flames, creating a cozy ambiance. Additionally, the stove includes a porcelain enamel finish, available in various colors, allowing homeowners to choose a style that complements their home decor.

Safety is another critical aspect of the 1537Q. It is equipped with safety features such as an automatic shutoff system, which activates in case of malfunction, ensuring peace of mind for users. The compact size of the stove makes it easy to install in various locations within the home, offering flexibility and convenience.

In summary, the United States Stove 1537Q combines efficiency, versatility, and safety in a beautifully designed package. With its advanced technologies and user-friendly features, it remains a popular choice for those seeking an effective heating solution that does not compromise on style. Whether for a traditional or contemporary space, the 1537Q is built to provide lasting warmth and comfort.