United States Stove 1602M installation instructions Return AIR is Very Important, Combustion AIR

Page 5

INSTALLATION #2

Extending the hot air duct from the furnace into the existing plenum will help direct the flow of air from the furnace as well as the flow in the existing furnace. Ducting entering the existing plenum at an angle (approximately 45 degrees) will facilitate air flow from the furnace while diverting air from the existing furnace.

INSTALLATION #3

The baffle on this system should be made the full width of the furnace plenum in order to properly direct the air into the distribution ducts.

THE PLENUM OPENINGS DIFFER BETWEEN THE 1602 AND 1802 PLENUM OPENING

MODEL 1602 - 13” x 18” Rectangular MODEL 1802 - 18” x 18” Rectangular

RETURN AIR IS VERY IMPORTANT

When installing a Clayton Furnace, return air MUST BE in- corporated into the system. Return air can be provided by installing a separate duct system or by tying into the cold air return of an existing gas or oil furnace. The cold air return duct can be connected to the furnace with ei- ther a factory manufactured U. S. Stove filter box, model UFB908 or an equivalent fabricated from sheet metal.

When installing a cold air return, the minimum size shall be a 16” x 20” or equivalent (320 sq. in.) in order to insure proper furnace performance. Failure to provide return air ducts of the specified size will void your warranty.

A filter should be installed in the cold air return. Furnace fil- ters should be checked and cleaned/replaced regularly.

If return air is not provided, the warm air distributed into your home will be restricted and the efficiency of the furnace is decreased. Without a return air system, warm air will be drawn into your basement, unnecessarily heat- ing unused areas of the home. In extreme cases, if your basement or utility room is fairly airtight, the blowers on the furnace could depressurize the room and pull toxic flue gases from the furnace, a gas water heater, or gas furnace. The fumes could then be distributed throughout the house.

NEGATIVE

PRESSURE IN

BASEMENT

COMBUSTION AIR

All fires need air (specifically oxygen) to burn. Furnaces, fireplaces, and wood burning furnaces need enough oxy- gen for complete combustion of their fuels. The incom- plete combustion that takes place when a furnace is “air starved” causes carbon monoxide (CO) to be formed in quantities that can be dangerous inside a well sealed house. Having a source of combustion air from outside the home will prevent “air starvation” of the furnace. A simple positive air supply can be constructed using dryer vent and a modified termination.

USSC

5

Image 5
Contents Ussc Disclaimer Notice IntroductionClearances Locating Your FurnaceCreosote Formation and Need For Removal Smoke Pipe InstallationChimney Requirements Connecting HOT AIR Duct To Furnace Important Information for ALL Connector PipesInstallation Examples Dampers on Stove PipesCombustion AIR Return AIR is Very ImportantShaker Grate Handle Furnace Assembly InstructionsDoor Handles ASH Door Spin DraftDistribution Blower & ACC Spin DamperSpring Handles Wiring Diagram 110F 130F Starting a Coal FireOperating Notes Solution Trouble Shooting and Problem SolvingParts Diagram Key Description Qty Parts Diagram and ListUFB908 Cold AIR Return / Filter BOX Optional KIT 16DIKL Forced Draft Blower Optional KITDR6 6 Draft Regulator Optional KIT Domestic HOT Water Coil Optional KITGuide to Burning Coal in Your Furnace Bulletin RC454Banking the Fire Ussc Ussc HOW to Order Repair Parts

1602M specifications

The United States Stove 1602M is a highly regarded model in the world of wood and coal stoves, designed to provide efficient heating with a classic aesthetic that complements any home décor. This model is particularly popular among eco-conscious homeowners seeking to reduce their carbon footprint. The stove's robust construction and advanced features make it an excellent choice for those who desire both functionality and reliability.

One of the main features of the United States Stove 1602M is its impressive heating capacity. With a heating area suitable for up to 1,200 square feet, it is perfect for small to medium-sized rooms. The stove’s nominal output of 70,000 BTUs ensures that it can effectively warm up spaces on even the coldest days, providing a cozy environment for the household.

The 1602M employs a traditional front-loading design, which makes fueling the stove straightforward and convenient. It is built with a firebrick-lined interior, which enhances heat retention and promotes efficient combustion. This design feature allows the stove to radiate heat evenly while maximizing the burn time of the fuel used.

One of the standout technologies integrated into this stove is its advanced air wash system, designed to keep the glass door clean and free from soot buildup. This feature allows for an unobstructed view of the flickering flames, enhancing the ambiance of the home. The stove is equipped with an adjustable primary air control, which grants users the ability to regulate the airflow according to their heating needs.

Built with durable cast iron materials, the 1602M is designed to withstand high temperatures while maintaining its structural integrity over time. The classic matte black finish adds to the stove's aesthetic appeal, ensuring it fits seamlessly into various interior styles, from rustic to contemporary.

Safety is also a priority with the United States Stove 1602M. It comes with a built-in safety screen and a thermal safety shut-off feature that prevents overheating. This aspect enhances peace of mind for users, especially in households with children or pets.

In summary, the United States Stove 1602M is a blend of tradition and modern technology, offering efficient heating performance, user-friendly operation, and safety features that make it an outstanding choice for warmth and comfort during the colder months. Its combination of form and function makes it a worthwhile investment for any home.