United States Stove 1600M Operating Notes, Canadian Requirments for Supplementary Add-on furnaces

Page 12

OPERATING NOTES

Do not over draft the furnace! It is designed to operate at .06 inches of water column and must be set with a draft gauge to maintain a steady draft. (Barometric Damper recommended.)

Do not allow ashes to build up higher than 2" above grates.

Be extremely careful when removing furnace ash pan; it can get very hot.

With new steel, there is a small amount of oil or dirt on the metal. You may smell an odor. This is normal during the first operation. You may want to assemble the furnace out of doors and build a small fire in it to "burn off" this dirt and oil before installing the unit.

The furnace is designed to burn air dried wood at a predeter- mined firing rate. Over firing could result in damage to the heat exchanger and cause dangerous operation. Over firing occurs when the ash door is left open during operation or a highly volatile fuel, i.e. large amounts of small kindling, is used.

When tending the firebox always pull the baffle slide rod out prior to opening load door. Open load door slowly to avoid a "flash back". After closing load door, push the baffle slide rod to the rear.

Equip your home with fire extinguishers and smoke detectors appropriately located.

Inspect air filters regularly. The air filter in the filter box should be changed at least every 30 days.

Oil motor on forced air draft every 90 days with a few drops of 30 wt. oil.

The distribution blower motor may be one of two types. If the motor has sealed bearings, no oiling is required.

If the motor is equipped with fill holes, the motor should be oiled every 90 days with several drops of 30 wt. oil.

Check the fit on the load door. It must fit tightly. If it does not, check for deterioration or wear of the ceramic rope seal. Replace defective seals.

Inspect and clean your chimney and stove pipe regularly.

In event of chimney fire, shut all draft controls and call your fire department immediately. Alert everyone in the house. If the fire is still burning vigorously, throw baking soda into firebox or discharge a fire extinguisher into the firebox. After chimney fire is over, completely inspect system for damage before further use.

Slow fires: It is not recommended burning the Clayton furnace any more than necessary early in the fall and late spring, as you cannot keep the firebox hot enough (without overheating your home) to burn gases. Slow fires can cause excessive creosote build-up in smoke pipe, chimney and firebox.

Wood should be placed directly onto the cast iron grate of the Clayton furnace. Do not use additional grates and/or irons.

In the event of a power failure, you may operate the 1600M furnace provided the following instructions are followed:

1.Any air filter should be removed.

2.If the motorized natural draft is used, the draft cap is to be set at a 1/2 inch opening. If the forced air draft is used, the damper on the built-in draft regulator will automatically open to the preset factory spacing.

Do not burn garbage, plastics, gasoline, drain oil or other flammable liquids. Plastics, when burned, form hydrofluoric and hydrochloric acids which will damage and destroy your furnace pipe and chimney. The burning of trash or oil can result in an extremely hot fire and is sometimes a cause of chimney fires. NEVER BURN GREEN WOOD OR TIRES.

Do not store fuel or other combustible material within marked installation clearances.

Disposal of Ashes - Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled outside.

NOTE: For further information on using your furnace safely, obtain a copy of the National Fire Protection Association publi- cation "Using Coal and Wood Stoves Safely." NFPA NO. NW-8- 1974. The address of the NFPA is 470 Atlantic Ave., Boston, Massachusetts 02210.

THIS IS A WOOD AND COAL

BURNING FURNACE AND SHOULD NOT BE ALTERED

IN ANY WAY!

Canadian Requirments for Supplementary

(add-on) furnaces.

Do not use duct elbows having an inside radius of less than 6 in. (150mm) on the (oil, electric, gas) furnaces.

On electric furnaces, Do not connect to a down flow furnace.

Do not connect ductwork so that a reverse flow is possible.

Operate the (oil, electric, gas) furnace periodically to ensure that it will operate satisfactorly when needed.

Do not relocate or bypass any of the safety controls in the original (oil, electri, gas) furnace installation.

Do not connect to any gas furnacethat has not been certified initiallyas complying with CAN/CGA-2.3

The operation of the gas furnace must be verified for accept able operation before and after installation of the add-on appliance by a gas fitter who is reconized by the regulatory authority.

Do not connect to any gas furnace that is not equipped with an air-circulation blower, or to a chimney or vent serving a gas furnace or gas appliance.

This Add-On Supplymentary Furnace should only be installed on a furnace duct system and chimney that are in good operating condition.

Outside Combustion air may be necessary if:

1.The solid-fueled fired appliance does not draw steadily, smell, experiences smoke roll-out, burn poorly, or back drafts whether or not there is combustion present.

2.Any of the above syptoms are all eviated by opening a window slightly on a calm day.

3.The house is equipped with a well-sealed vapor barrier and tight fitting windows and/or has powered devices which exhaust house air.

4.There is excessive condensation on the windows in the winter.

5.A ventilation system is installed in the house.

12

Image 12
Contents United States Stove Company Introduction Locating Your FurnaceClearances Chimney RequirementsSmoke Pipe Installation Important Information for ALL Connector PipesCreosote Formation and Need For Removal Installation Examples Connecting HOT AIR Duct to FurnaceInstallation NO.1 Dampers on Stove PipesInstallation no Return AIR is Very ImportantCombustion AIR Assembly Instructions Door Handle InstallationFuel & ASH Door Latch Installation Brick Installation PRE-INSTALLED AT FactoryModel 1600M Plenum Opening Distribution Blower Installation Shaker Grate Handle InstallationSmoke Door Installation Installing ASH Door Spin DraftElectrical Installation ALL Wiring Must be Done by a Qualified Electrician Testing and Operating Procedures TestingOperating Notes Canadian Requirments for Supplementary Add-on furnacesTrouble Shooting and Problem Solving SolutionParts List Model 1600M4038 Models 1600M Forced AIR Draft Parts List Kit # PRE-ASSEMBLED AT FactoryInstallation of Optional Equipment Installing Domestic HOT Water CoilInstalling Optional Back Draft Damper HOW to Order Repair Parts

1600M specifications

The United States Stove 1600M is a highly efficient and versatile heating solution designed to provide warmth and comfort in homes. This stove, known for its robustness and excellent performance, primarily operates using wood, making it an eco-friendly choice for heating. It appeals to those who value sustainability while ensuring a cozy atmosphere in their living spaces.

One of the standout features of the 1600M is its large viewing window, which allows users to enjoy a picturesque view of the flickering flames. The door is designed to enhance safety while being stylish, combining functionality with aesthetics. Additionally, the large firebox has ample capacity, enabling the stove to hold logs up to 18 inches long. This means less frequent reloading and longer burn times, which translates to increased convenience for homeowners.

The 1600M employs advanced technology that maximizes heat output while minimizing emissions. With an efficient design, it boasts a high heat output of up to 74,000 BTUs, making it suitable for heating spaces up to 2,000 square feet. This powerful output is complemented by a patented re-burn technology that ensures nearly complete combustion, resulting in a cleaner burn and reducing the amount of smoke released into the atmosphere.

Another noteworthy characteristic of the United States Stove 1600M is its adjustable air control system. This system allows users to easily manage the burn rate and heat output, giving them greater control over their heating needs. Whether you prefer a slow-burning fire for a long, steady heat or a quick, intense burn for immediate warmth, this stove can accommodate your preferences.

The construction of the 1600M features heavy-duty steel, ensuring durability and longevity. Its solid build not only offers stability but also helps maintain heat over extended periods. With easily accessible features such as an ash pan for easy clean-up, the stove exemplifies user-friendly design.

In summary, the United States Stove 1600M combines efficiency, style, and practicality. With its large firebox, advanced burning technology, and ease of use, it stands as a prime choice for anyone looking to invest in a reliable and effective wood-burning stove. As a result, it offers not just a source of heat, but a centerpiece for homes that value warmth and comfort.