United States Stove 1500 owner manual Locating the Furnace

Page 7

Locating the Furnace

1.The furnace should be located in the same room as the central system and as close as possible, but not closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace. (See Fig. 2)

2.The unit will require installation with the following clearances:

Unit to sidewall

12"(305mm)

Unit to backwall

30"(760mm)

Chimney connector pipe to sidewall

.....................................21"(530mm)

Chimney connector pipe to backwall

.....................................18"(460mm)

Hot air ducts to combustibles

.......................................6"(150mm)

(Refer to Fig. 2 & 3)

3.Place the furnace on a noncombus- tible floor.

4.Check figures 2 and 3. Be sure you have the clearances shown from the furnace and the connector pipe to combustible surfaces. If you have a solid brick or stone wall behind your furnace, you can place the furnace as close as you wish to the wall. If the wall is only faced with brick or stone, treat it as a combustible wall.

18"

6" CHIMNEY

12"

9"

CENTRAL

FURNACE

 

 

48"

Figure 2

18"

6" SOLID DAMPER

6" BAROMETRIC

DRAFT REGULATOR

(OPTIONAL)

18"

NON-COMBUSTIBLE FLOOR

Figure 3

7

Image 7
Contents Solid Fuel Warm AIR Furnace Congratulations Keep children away Do not touch during operation Rules for safe installation and operation HOW the Furnace Functions Dimensions of Furnace Locating the Furnace Masonry Chimney Chimney ConnectionAdjusting the Barometric Draft Regula- tor Rules for Connector Pipe InstallationAssembly of Furnace Page Power Failure Instructions InstallationFUEL, Models 1500 & 1537G Operating InstructionsChimney Maintenance Service HintsModel 1500 & 1537G Repair parts KEY Description QTY Box Page Appendix Installation B Page Installation F Installation H List of Problems Possible Cause Solutions Trouble Shooting Tips for Warm Air Furnace