Control Panel Overview
Turning the heater ON/OFF, as well as adjustments for the fuel feed rate and room fan speed are performed by pressing the appropriate button(s) on the control panel which is located on the lower
This unit can be changed between an automatic operation or a manual operation. The controller comes default in the automatic mode.
•ON/OFF
Pressing the “ON” button on the control panel will begin the
Pressing the “OFF” button on the control panel will cause the heater to enter its
•HEAT RANGE
Pressing the “Heat Range” arrows, up or down, will adjust the amount of fuel being delivered to the burnpot.
•DRAFT FAN
The draft fan (exhaust) will come on as soon as the “ON” button is pressed. The fan will automatically adjust its speed in accordance to the heat range setting. However, this speed can be manually operated by pressing the “Draft Fan” arrows up or down. “Draft Fan” when pressed, the display will show
•ROOM FAN
The room fan will come on once the unit has reached operating temperature. By pressing the “Room Fan” buttons, the display will show
•AUX - USED TO RETURN THE STOVE TO THE FACTORY SETTINGS
To return the stove to it’s original factory settings, press and hold the AUX UP and AUX DOWN buttons simultaneously for 3 seconds.
•AUGER DELAY
The “Auger Delay” button can be used to pause rotation of the Auger for approx. 1 minute. This can be cancelled by pressing the “ON” button. The “Auger Delay” is normally used only during the start up cycle to slow the fuel delivery down during the initial ignition.
•MODE
The “Mode” button is used to switch between manual and automatic mode. When in auto mode, the fans and auger will operate at preset intervals unless changed manually using the buttons mentioned above. When in manual mode, the draft fan (exhaust) will operate at full speed (100%).
During normal operation, the unit is constantly monitored for problems. In the event of an error condition, the unit will stop and an error will be displayed. See the list of error codes found at the end of this manual.
12 | USSC |