BENDIX SD-08-2403 manual Operation, Preventive Maintenance and Checking Serviceability

Page 3

The desiccant beads are held in place by steel perforated plates and filter cloths. The top plate is held in place by a spring, and the bottom plate rests on a shoulder approximately 1/8" from the bottom of cartridge housing.

The end cover assembly is retained by a lock ring, cap screws and retainers and houses the purge valve and heater assembly if so equipped.

The heater and thermostat assembly prevent freeze-up in the purge drain valve when the dryer is used in severe winter conditions. The heater and thermostat assembly is standard in the AD-2air dryer and was optional equipment for the AD-1air dryer. The 12 volt, 60 watt and 24 volt, 60 or 120 watt DC heater and thermostat assembly has an operating range between 45°F and 85°F.

NOTE: The heater and thermostat assembly provided with the AD-2air dryer has a 3/16" diameter threaded electrical terminal protected by a boot. The AD-1air dryer assembly incorporates a #16 gauge lead wire. Both types are serviceable. The heater and thermostat assembly should be connected to the “on” position of the engine control or ignition switch and protected with the proper size fuse. For details on installation, please refer to the “Installation” section.

OPERATION

The operation of the air dryer can best be described by separating the operation into two cycles; the charge cycle and the purge cycle.

Charge Cycle (Figure 3) Compressor in Compressing Cycle

-With the compressor in its “loaded” or compressing cycle, air from the compressor enters the air dryer through the discharge line. When the air, along with the water and contaminants, enter the air dryer, the velocity or speed of the air reduces substantially and much of the entrained liquid drops to the bottom or sump of the air dryer. The initial air flow is toward the bottom of the dryer, but air flow direction changes 180° at the bottom of the air dryer, dropping some water and oil.

The air now passes through the oil separator filter which removes oil and foreign material but does not remove water vapor. At this point, the air remains saturated with water.

The filtered air and vapors penetrate the desiccant drying bed and the adsorption process begins. Water vapor is removed from the air by the desiccant.

The unsaturated “dry” air passes through the ball check valve and purge orifice into the purge volume. From the purge volume air flows through an outlet check valve, and into the first reservoir.

NOTE: The AD-1air dryer does not incorporate an integral outlet check valve. The single check valve in an AD-1air dryer installation would be located in the line between the AD-1air dryer outlet port and the first reservoir.

Purge Cycle; (Figure 4) When desired system pressure is reached, the governor cuts out, pressurizing the unloader cavity of the compressor which unloads the compressor (non- compressing cycle). The line connecting the governor unloader port to the end cover purge valve port (bottom of the air dryer) is also pressurized, opening the exhaust of the purge valve to atmosphere. With the exhaust of the purge valve open, contaminants in the discharge line and dryer sump are purged, or forced past the open exhaust out to atmosphere.

The reverse air flows across the desiccant and starts the removal process of moisture from the desiccant surface. Dry air flowing from the purge volume through the purge orifice and across the drying bed further dries the desiccant.

The combination of these reverse flows strips the water vapor from the desiccant (drying bed). This normally takes between 15-30 seconds.

The desiccant becomes activated from this cycle and is now ready for another charge cycle, which occurs when the compressor returns to the compressing cycle. It is for this reason the air dryer must be purged for 30 seconds, after receiving moisture saturated air for a maximum of 90 seconds from a 12 CFM compressor.

WARNING!

This air dryer is intended to remove moisture and other contaminants normally found in the air brake system. Do not inject alcohol, anti-freeze, or other de-icing substances into or upstream of the air dryer. Alcohol is removed by the dryer, but reduces the effectiveness of the device to dry air. Use of other substances can damage the air dryer and may void the warranty.

PREVENTIVE MAINTENANCE AND CHECKING SERVICEABILITY

Important: Review the warranty policy before performing any intrusive maintenance procedures. An extended warranty may be voided if intrusive maintenance is performed during this period.

Every 900 operating hours or 25,000 miles or every three

(3) months:

1.Check for moisture in the air brake system by opening reservoirs, drain cocks, or valves and checking for presence of water. If moisture is present, the desiccant may require replacement; however, the following conditions can also cause water accumulation and should be considered before replacing the desiccant:

3

Image 3
Contents SD-08-2403 Sectional Views Operation Preventive Maintenance and Checking ServiceabilityPage Electric Power to the Dryer Replacing or Rebuilding the AD-1AND AD-2AIR Dryer ReassemblyEnd Cover Removal Reinstalling the Desiccant Cartridge AD-1AND AD-2AIR Dryer Disassembly of Desiccant CartridgeRebuilding the Desiccant Cartridge Page Assembly Disassembly Rebuilding the AD-1AIR Dryer END Cover AssemblyRebuilding the AD-2AIR Dryer END Cover AssemblyCheck to be certain a film of barium base grease is Rebuilding the AD-2AIR Dryer Outlet Port Check ValveMaintenance KIT for the AIR Dryer Installation of AD-1AND AD-2AIR DryerTypical Installation for the AD-1AIR Dryer AD-2AIR Dryer Troubleshooting Chart Symptom