BENDIX BW1948 manual DRM/AD-ISAIR Dryer Troubleshooting Chart

Page 14

DRM/AD-IS®AIR DRYER TROUBLESHOOTING CHART (Continued)

SYMPTOMS

CAUSE

REMEDY

10. The air dryer purge

A. Compressor fails to

A. Check air hose from governor to compressor for

piston cycles rapidly in

“unload”.

a missing, kinked or restricted line. Install or

the compressor

 

repair air hose.

unloaded (non-

 

Repair or replace compressor unloader.

compressing) mode.

 

 

 

 

 

14

Image 14
Contents SD-98-9808 Turbo Cutoff Valve Safety Open Purge See AIR Dryer Operation GeneralAD-ISAIR Dryer Purge Cycle Preventive Maintenance AD-ISAIR Dryer Heater Thermostat Connector Operation & Leakage Tests Also see Video BW2327Rebuilding the AD-ISAIR Dryer Maintenance Kits Available GeneralTemporary AIR Dryer Bypass Braking System ProtectionRoadside Inspection Assembly DRM/AD-ISAIR Dryer Troubleshooting Chart DRM/AD-ISAIR Dryer Troubleshooting Chart DRM/AD-ISAIR Dryer Troubleshooting Chart DRM/AD-ISAIR Dryer Troubleshooting Chart DRM/AD-ISAIR Dryer Troubleshooting Chart