BIOS Setup
▶H/W Monitor
Press <Enter> to enter the
▶CPU Smart FanTarget
The Smart Fan function controls the CPU fan speed automatically depending on the current temperature to keep it with in a specific range. You can enable a fan target value here. If the current CPU fan temperature reaches to the target value, the smart fan function will be activated.
▶CPU Min.Fan Speed(%)
This item allows users to select how percentage of minimum speed limit for the CPU fan.
▶SYS Fan 1 Control
This item allows users to select how percentage of speed for the SYSFAN1.
▶CPU/ System Temperature, CPU FAN/ SYS FAN 1/ 2 Speed, CPU Vcore, CPU IO, DRAM Voltage, GPU Voltage, 3.3V, 5V, 12V
These items show the current status of all of the monitored hardware devices/com- ponents such as CPU voltage, temperatures and all fans’ speeds.
▶Power Management Setup
Press <Enter> to enter the
▶EuP 2010
This item is designed for Energy Using Products Lot 6 2010 (EuP) aka Energy Re- lated Products (ErP). To reduce Power Consumption when system off or standby mode.
Note: When “Enable” EuP 2010, system doesn’t support RTC wake up event func- tion.
▶Restore on AC Power Loss
This item specifies whether your system will reboot after a power failure or interrupt occurs. Settings are:
[Power Off] | Always leaves the computer in the power off state. |
[Power On] | Always leaves the computer in the power on state. |
[Last State] | Restore the system to the status before power failure or interrupt |
| occurred. |