Lennox International Inc SLP98DFV manual Service Reminder, Safety Precautions, Planned Service

Page 6

Burner Flame

CAUTION

To ensure proper operation, a licensed professional service technician (or equivalent) should check the burner flame and conduct a combustion analysis annually.

Electrical

1 − Check all wiring for loose connections.

2 − Check for the correct voltage at the furnace (furnace operating).

3 − Check amp−draw on the blower motor.

Motor Nameplate__________Actual__________

Service Reminder

Call your Lennox service technician if the unit will not oper- ate. Before calling, always check the following to be sure service is required:

1 − Check that electrical disconnect switches are ON.

2 − Check room thermostat for proper setting.

3 − Replace any blown fuses or reset circuit breakers.

4 − Gas valve should be ON.

5 − Air filter should not be plugged, which will limit air flow. 6 − Is gas turned on at meter?

7 − Is manual main shut−off valve open?

Record the model and serial number of the furnace. These numbers are on the unit nameplate, which is located on the blower deck below the combustion air inducer.

Serial Number __________________

Model Number __________________

Safety Precautions

If you discover any of the following, shut down your unit, and contact a Lennox dealer for an inspection by a licensed professional service technician (or equiva- lent).

D If you repeatedly hear any new or unfamiliar sounds while your unit is operating, there may be a problem. For example, poorly performing burners can produce unfa- miliar noises.

DIf you smell any unusual odors, your unit may be operat- ing improperly. For example, units can give off unfamil- iar odors if components are required to operate in ab- normal conditions.

DLook for visible signs of a malfunctioning unit. Examples include unusual amounts of condensate on windows in- side your house, visibly burnt components or unusual dirt or rust accumulations on the vent pipe or in the unit.

DIf you experience headache, nausea, fatigue, or dizzi- ness, the cause could be exposure to carbon monoxide gas. This is often misdiagnosed as the flu because symptoms are similar. If you suffer from flu−like symp- toms that are exaggerated at home, but seem to sub- side while you are away from the house, exposure to carbon monoxide could be the cause.

Your vigilance may pay off in early detection of a problem before either personal injury or property damage occurs. Do not hesitate to contact a licensed professional service technician (or equivalent) as an investment in your well be- ing.

Planned Service

You should expect a service technician to check the follow- ing items during an annual inspection. Power to the unit must be shut off for the service technician’s safety.

Fresh air grilles and louvers (on the unit and in the room where the furnace is installed) − Must be open and unob- structed to provide combustion air.

Burners − Must be inspected for rust, dirt, or signs of water.

Vent pipe − Must be inspected for signs of water, damaged or sagging pipe, or disconnected joints.

Unit appearance − Must be inspected for rust, dirt, signs of water, burnt or damaged wires, or components.

Blower access door − Must be properly in place and pro- vide a seal between the return air and the room where the furnace is installed.

Return air duct − Must be properly attached and provide an air seal to the unit.

Operating performance − Unit must be observed during operation to monitor proper performance of the unit and the vent system.

Combustion gases − Flue products must be analyzed and compared to the unit specifications.

Problems detected during the inspection may make it nec- essary to temporarily shut down the furnace until the items can be repaired or replaced.

Pay attention to your furnace. Situations can arise be- tween annual furnace inspections that may result in unsafe operation.

Page 6

Image 6
Contents SLP98DFV Series This furnace is equipped with safety devices that protect SLP98DFV Parts IdentificationSafety Instructions Start−Up & Operation Information Carbon monoxide gas is invisible, odorless and tox- icMaintenance FiltersService Reminder Safety PrecautionsPlanned Service Repair Parts List