Raypak 399B warranty Specifications, Rates of Flow and Pressure Drops

Page 2

Delta Limited – Type H

Models 399B-899B

Model

NOTE: Pump location varies

based on model selected

SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

Approx.

 

MBTUH

A

G

H

K

T

W

Amp.

Shipping

Model

Input

Output

Width

NPT

NPT

 

 

 

Draw*

Wt. (Lbs)

399B

399

335

43

¾

2

6

6

18-1/2

< 6

445

499B

500

420

50

1 ¼

2

6

6

22

< 6

545

649B

650

546

60 ½

1 ¼

2

8

6

27-1/4

< 6

590

749B

750

630

67 ½

1 ¼

2

8

6

30-3/4

< 6

675

899B

900

756

78

1 ¼

2

8

6

36

< 7

740

* Pump not included

Dimensions are in inches.

Rates shown are for natural or propane gas, and elevations up to 4,500 feet. For installation above 4,500 feet, please contact manufacturer.

Recommended natural gas supply pressure is 7 – 10.5” WC. Recommended propane gas supply pressure is 11 - 13” WC.

RATES OF FLOW AND PRESSURE DROPS

Model

10°F ∆T

20°F ∆T

30°F ∆T

Min. Flow

 

Max. Flow

 

GPM

∆P (ft)

GPM

∆P (ft)

GPM

∆P (ft)

GPM

∆P (ft)

∆T

GPM

∆P (ft)

∆T

399B

68

5.4

34

1.5

22

<1

20

<1

34

90

10.0

 

7

499B

85

9.2

42

2.3

28

1.1

21

<1

40

90

10.5

 

9

649B

N/A

N/A

55

4.0

36

1.8

28

1.1

40

90

10.7

 

12

749B

N/A

N/A

64

5.5

42

2.5

32

1.6

40

90

11.0

 

14

899B

N/A

N/A

76

8.5

51

3.8

38

2.2

40

90

11.8

 

16

Basis is 20 GPM or 40°F ∆T for minimum flow, 90 GPM for maximum flow.

Raypak, Inc. ƒ 2151 Eastman Avenue, Oxnard, CA 93030 ƒ (805) 278-5300 ƒ Fax (800) 872-9725 ƒ www.raypak.com

Catalog No.: 2000.461A

Effective: 07-21-10

Replaces: 9-15-07

Image 2
Contents Controls Temperature ControlsHeat Exchanger Gas TrainSpecifications Rates of Flow and Pressure Drops