Maytag HE21250PC, HE21282PC Troubleshooting contd, This will not discontinue power from the water

Page 34

Troubleshooting (cont'd)

Operational Conditions (cont'd)

THERMOSTATDIAGNOSTICS

The programmable thermostat will use the upper and lower temperature sensors (thermistors) to determine when either the upper or lower heating element is not functioning. It can also detect a faulty temperature sensor. The thermostat will use the service icon and its associated codes to indicate the specific failure condition and will also save the last failure condition,

To display the last failure, depress and hold the up (A) arrow or the down ( • ) arrow button for 4 seconds while in the nor- mal run mode. Be Careful; depressing the "ERASE" button while the last failure is displayed will erase the stored failure.

1.No Water/Dry Fire Warning - If the sensors indicate a rise in temperature greater than 50°F in the first minute after power-up, the control will display a "NO WATER" icon indicating that there is no water in the tank. This will immediately shut offpower to both dements.

[

]

_, CAUTION

]

[This will not discontinue power from the water

 

[ heater.

 

2.Upper Temperature Sensor Failure - If the upper sensor is either open or shorted, the "SERVICE" icon and the let- ters "U" and "S" will be displayed. The thermostat will then use only the lower heating element and lower temper- ature sensor to control the water temperature until the upper sensor has been replaced.

3.Lower Temperature Sensor Failure - If the lower sensor is either open or shorted, the "SERVICE" icon and the let- ters "L" and "S" will be displayed. The thermostat will then use only the upper heating element and upper temperature sensor to control the water temperature until the lower sen- sor has been replaced.

4. Upper Element Failure -Tests after 90 minutes of contin-

uous upper element heating without an increase in upper water temperature. The thermostat turns off the upper ele- ment and tries for 30 minutes to raise the temperature of the upper sensor using the lower dement. If the upper tem- perature sensor rises using the lower element, the upper ele- ment will again be tried. After 30 minutes, if the upper ele- ment does not raise the upper water temperature on the second attempt, then an upper element failure will be indi- cated by displaying the "SERVICE" icon and the letters "U" an d " E" . The lower element will only be used to heat the water until the upper element has been replaced.

5. Lower Element Failure- After 120 minutes of continuous

lower element heating without an increase in lower water temperature, lower element failure will be indicated by dis- playing the "SERVICE" icon and the letters "L" and "E'. Replace the lower heating element.

6.High Limit Device Failure - Ira lower element failure occurs when the upper element has also failed, the thermo-

stat will determine that the high limit device has failed. High limit device failure will be indicated by displaying the

"SERVICE" icon and the letter "C". Replace the high limit device.

7. Re-Check - The system will run a failure event sequence three (3) times before it assumes a final service code.

34

Image 34
Contents Iviayiag Safety Instructions DEATH, Serious Bodily INJURY, or Property Damage AwarningSafety Instructions contd AcautionTable of Contents Product Specifications Customer InformationAccessoriesand Tools Needed AccessoriesInstallation Instructions Water passing out DrainTypical Installation Instructions for Installation contdLocating The New Water Heater Convertible Lower Element OUS Bodily INJURY, or Property DamageInstructions for Installation contd Water PipingInsu Lati on Conduit Temperature PressureValve Pipe Do notcapor plugConverting the Lower Element Instructions for Installation contdFilling the Water Heater Conversionparts BussbarHazard of Electrical SHOCK! Before removing ContdProperty Damage Converting Lower Element AcautionWiring Diagram Wire Conduit Water Heaters Equipped for ONE VoltageSelecting Thermostat Location DEATH, Serious Bodily INJURY, or Property DamageAR .ES AC T I c ALFSelectingThermostatLocationcontd Remote HermostatNGE/WH,TET.E--OT Dischargepipe Temperature Pressure ReliefvalveCold 6AIR GAPInstructions for Operation Temperature ConditionsLe temperature setting that satisfies your hot Intended to produce hot water. Water heated to aInstructions for Operation contd Programming the Thermostat contdOverride Instructions for Operation contdLjvjiyag m BU1TON Programming the Thermostat contd DEATH, SER OUS BOD LY NJURY, or Property DamageTEMPERATURE-PRESSURE Service and MaintenanceDEATH, Serious Bodily INJURY, or Property Element Cleaning Service and Maintenance contdReplacement When the water heater is in use Replacement contd Service Drain Valve Washer ReplacementHandleand Capassembly Start Up Conditions TroubleshootingOperational Conditions Not EN Ough or no HOT Water Troubleshooting contdWater is TOO HOT Troubleshooting contd This will not discontinue power from the waterHazard Electrical Leakage CheckpointsLY INJURY, or PR Operty Damage Page Repair Parts List 660010109002403 660010119001609 660010129001608Model Numbers Repair Parts List contdMaytag Electricwat ER Heat ERS GallonSee Note on Descripti on NumbersSee Note Warranty 66001469

HE21282PC, HE21250PC specifications

The Maytag HE21250PC and HE21282PC washers are part of Maytag's commitment to quality and performance in laundry appliances. Designed to meet the needs of modern households, these models boast a range of impressive features and technologies that enhance cleaning efficiency and ensure garment care.

One of the standout features of both the HE21250PC and HE21282PC is their high-efficiency (HE) design. These washers are engineered to use less water and energy while providing powerful cleaning capabilities. The Energy Star certification reflects their commitment to sustainability, making them an eco-friendly choice for consumers looking to reduce their environmental impact.

Both models come equipped with a robust motor that allows for faster spin speeds, effectively removing excess water from clothes and reducing drying time. This feature not only saves time but also contributes to lower energy bills when used in conjunction with a dryer.

The Maytag HE21250PC and HE21282PC also incorporate advanced wash cycles and settings. With multiple wash options including normal, delicate, and heavy-duty cycles, these washers are versatile enough to handle a wide variety of fabrics and soil levels. The specialized wash programs are designed to optimize cleaning performance, ensuring that even the toughest stains are effectively removed.

Another characteristic that sets these models apart is the spacious drum capacity. The large capacity allows users to wash more items in a single load, which is particularly beneficial for families or households with frequent laundry needs. This feature not only saves time but also contributes to water and energy efficiency.

In terms of user experience, both washers feature intuitive controls and clear display panels, making it easy to select preferred settings. The quiet operation technology minimizes noise during the wash cycle, allowing for a more peaceful home environment.

Durability is also a key characteristic of the Maytag HE21250PC and HE21282PC. Built with high-quality materials and backed by a solid warranty, these washers are designed to provide reliable performance for years to come. The reinforced springs and strong drum construction ensure that the machines can handle heavy loads without compromising structural integrity.

In summary, the Maytag HE21250PC and HE21282PC offer a blend of efficiency, performance, and durability. With their range of features, advanced technologies, and user-friendly design, they stand as strong contenders in the competitive landscape of high-efficiency washers, catering to the needs of modern laundry routines.