Raypak 8300, 6300, 5300 owner manual Plumbing Diagrams, Water

Page 13

Plumbing Diagrams

Water In

Filter

Water Out

(from pool

(to pool

or spa)

 

 

or spa)

 

 

For systems with pumps of less than 2 HP (under 80 gpm), no external bypass is required. Connections are 2-inch unions. Plumb the heat pump after the filter and before any chlorinators.

Water In

 

Water Out

(from pool

Filter

or spa)

(to pool

 

 

 

or spa)

For systems with pumps of 2 HP or greater (over 80 gpm), an external bypass is required. Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump. Connections are 2-inch unions. Plumb the heat pump after the filter and before any chlorinators.

10

Image 13
Contents Raypak Swimming Pool Heat Pump Product Safety Signs and Labels Swimming Pool Heat Pump Introduction Installation ConsiderationsII. Electrical Connections Typical System Electrical Power RequirementsIII. Water Connections IV. Controls and Indicator LampsPage VI. Seasonal Start-Up or Annual Check System Start-UpVIII. Summer Shutdown VII. Heat Pump Running TimeIX. Freeze Protection XI. Troubleshooting MaintenanceUnit is RUNNING, but not Heating Unit is not Running Condensation Seems Excessive XII. Service Call VerificationWater Plumbing Diagrams