P/N 472299
Figure 6.
6
Rev. B
MiniMax NT TSI w/DDTC WIRING DIAGRAM
|
| HIGH LIMITS |
|
|
|
|
|
|
| THERMAL FUSE |
|
|
| 115˚F |
|
|
|
|
|
|
|
| |
|
| R |
|
|
|
|
|
|
| W | W |
| O |
|
|
|
|
|
|
|
|
|
|
|
| R |
|
|
|
|
|
|
|
|
|
BK/W | G | 150˚F | W |
|
|
|
| W |
|
|
|
|
|
|
|
|
|
|
| ||||
BK |
|
|
|
|
|
|
|
|
|
|
|
|
|
| WATER PRESSURE |
|
|
|
| ||||
R/W |
|
|
| SWITCH | W |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
R |
|
|
|
|
|
| O |
|
|
|
|
|
|
|
|
| GY |
|
|
|
|
| |
|
|
|
|
| O |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| R |
|
|
| SEE OPERATION |
|
|
|
|
| W |
| ||
|
| & INSTALLATION |
|
|
|
|
| BL |
| ||
|
| MANUAL FOR |
|
|
|
|
| O |
| ||
|
| REMOTE CONTROL |
|
|
|
|
|
|
| ||
COM NO |
|
| { |
|
| P4 | P7 | PI0 | P11 |
| |
GY |
|
|
|
|
|
|
|
| |||
O O |
| J5 | J8 | J6 | J1 | J2 | J4 | J7 | JI0 | J11 |
|
|
|
|
|
|
|
| |||||
|
| POOL | COM | SPA | 24VAC | FAN | 24V | TFUSE/HLMT/PRESS | VLV | IGN MOD |
|
BLOWER |
|
|
|
|
|
| |||||
AIR PRESSURE SW. |
|
|
|
|
|
|
|
|
| P9 |
|
|
|
|
|
|
|
|
|
|
| J9 |
|
|
|
|
|
|
|
|
|
|
| THERMISTER |
|
DDTC
FOR 120 VAC
|
| R |
|
|
|
|
|
|
|
|
|
| ||
| R/W |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| TERM B |
|
| TERM | A |
| |
| BK |
|
|
|
|
| Y |
|
|
|
| |||
|
|
|
|
|
|
| BLOCK |
|
| BLOCK |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
BK/W |
|
|
|
| BK |
|
| BK | 1 |
| G |
| G |
|
|
|
|
|
|
|
| BL |
|
|
|
| |||
|
|
|
| O |
|
| W |
|
|
|
| 120 VAC | ||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| PR |
|
|
| W | 2 | W | W | N | W | OR |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| W |
|
|
|
|
| BK | BK |
| BK | 240 VAC |
|
|
|
|
|
|
|
|
| 3 | L | ||||
| GAS VALVE |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| BK |
|
|
|
|
|
| |||
R |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| BK | 4 |
|
|
|
|
| |
W |
|
| MV | G |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| W | BOND LOG |
| ||||
BL |
|
|
|
|
|
| W | 5 |
|
| ||||
|
| MV |
|
|
|
|
|
| (ON THE SIDE JACKET) | |||||
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| G |
| |
|
|
|
|
|
|
|
| FOR 240 VAC |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Y |
|
|
|
| ATTACH | |
|
|
|
|
|
|
|
|
|
|
|
| GROUND | ||
|
|
|
|
|
|
|
|
| W |
|
|
| ||
|
|
|
|
|
|
|
|
|
| BK |
|
| WIRE HERE | |
|
|
|
|
|
|
|
| Y |
|
| WIRE COLOR CODE | |||
|
|
| W |
|
|
|
| BK |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| W |
|
|
|
| O |
|
| BK | : BLACK |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| HOT SURFACE |
|
|
| PR |
|
| BL | : BLUE |
|
| |
|
|
| IGNITER |
|
|
|
|
|
| BR | : BROWN |
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| BR | FLAME SENSOR | PR O BK Y |
|
| R | : RED |
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| O | : ORANGE |
| |
|
|
|
|
|
|
|
| BLOWER |
|
| Y | : YELLOW |
| |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| W |
|
| G | : GREEN |
| |
|
|
|
|
|
|
|
|
|
| GY | : GRAY |
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| F1 | W |
|
|
| PR | : PURPLE |
| ||
|
| Y |
|
| F2 | W |
|
|
|
| ||||
|
| 240 | IGN/ |
|
|
|
|
|
|
| ||||
|
|
|
|
|
| W | : WHITE |
| ||||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
| VAC |
| O |
|
|
|
| |||
BL | BL |
| 120 | IGN/ | 24 |
|
|
| R/W | : RED W/WHITE TRACE | ||||
|
|
|
|
| ||||||||||
BK |
|
| FC | + |
|
|
|
| ||||||
|
|
| L1 |
| - |
|
|
|
| BK/W : BLACK W/WHITE TRACE | ||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| FS |
|
|
|
|
| IF ORIGINAL FACTORY WIRING MUST BE REPLACED, | |||||
|
|
|
|
|
|
|
|
| ||||||
| GY |
| PS |
|
|
|
|
| INSTALLER MUST SUPPLY UL/CSA APPROVED WIRE | |||||
| O |
|
|
|
|
|
| WITH 18 AWG, 600V, 105˚ C TEMP. RATING. |
| |||||
|
|
|
|
|
|
|
|
| ||||||
|
| TH |
|
|
|
|
|
|
|
|
|
|
| |
| R |
|
|
|
|
|
| THERMAL FUSE WIRING MUST BE REPLACED WITH | ||||||
|
| VAL |
|
|
|
|
| |||||||
| BL |
|
|
|
|
|
| 18 AWG, 600V, 150˚ C TEMP. RATING. |
|
| ||||
| W |
| GND |
|
|
|
|
|
|
|
|
|
|
|