MAINTENANCE

The quartz sleeve should be cleaned with warm soap and water every three months.

UV bulb should be replaced every 9-12 months. The bulb does not normally burn out, however the efficiency of the bulb decreases after one year.

Contact your local water treatment professional for replacement cartridge and bulb pricing or call 1-800-645-0267 for a dealer near you.

Leaks…

At inlet/outlet connections:

• Use Teflon® tape.

Between cap and housing:

Make sure that the O-ring is clean, lubricated and properly seated.

Hand-tighten the housing.

Check cartridge length. If cartridge is too long, replace with proper length cartridge.

At UV quartz sleeve

Turn off all electrical power to the unit by unplugging or throwing the circuit.

Remove UV lamp and unscrew housing (See UV lamp replacement).

Check quartz sleeve for cracks, leaks and loose fittings.

Check that O-rings between quartz sleeve and cap are secure and have not been cut or damaged.

If the sleeve is broken replace with a new quartz sleeve and new O-rings.

TECHNICAL SUPPORT

Call our technical support staff to have any question answered: 1-800- 861-8758. Outside of the United States, call (920) 457-9435.

WARRANTY

Pentek warrants to the original owner (under normal use): Ultra Violet Systems to be free from defects in material and/or workmanship one (1) year from the date of purchase. Any replacement products furnished will be free from defects in material and/or workmanship for the remainder of the original warranty period, or 30 days, whichever is longer. This warran- ty does not cover: (1) cartridges, UV bulbs, and accessories (2) defects not reported within the above time period, (3) items manufactured by other companies, (4) problems arising from failure to comply with Pentek instruc- tions, (5) problems and/or damage arising from acts of nature, abuse, mis- use, negligence or accident by any party other than Pentek, (6) problems and/or damage resulting in whole or in part from alteration, modification, repair or attempted alteration, modification or repair by any party other than Pentek, (7) noncompliance with applicable codes/ordinances.

If a defect in workmanship and/or material in a product or part covered by the warranty should arise, Pentek, at its sole discretion, will repair or replace the defective product or part (Pentek may consider, in good faith, the customer’s preference).

All claimed defective product must: (1) be authorized for return by Pentek with an RGA number (2) include proof of the purchase date of the product or part (3) returned to Pentek prior to the expiration of the warranty date, at the customer’s expense, shipment pre-paid, (4) be accompanied by a let- ter detailing the Model Number, Serial Number (if any), and a brief descrip- tion of the problem.

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, PENTEK DISCLAIMS ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCTS, PARTS AND ANY ACCOMPANYING WRIT- TEN MATERIALS.

To the maximum extent permitted by applicable law, Pentek shall not be liable for any damages whatsoever (including, but not limited to, loss of time, inconvenience, expenses, labor or material charges incurred in con- nection with the removal or replacement of the Ultra Violet Systems, spe- cial, incidental, consequential, or indirect damages for personal injury, loss of business profits, business interruption, loss of business information, or any other pecuniary loss) arising out of the use of or inability to use the defective products or parts, even if Pentek has been advised of the possi- bility of such damages.

Pentek's’ maximum liability under any provision of this Limited Warranty shall be limited to the amount actually paid for the Ultra Violet System. NOTE: Because some states do not allow the exclusion or limitation of incidental or consequential damages, the above limitations or exclusions may not apply.

THIS WARRANTY GRANTS SPECIFIC LEGAL RIGHTS, AND OTHER RIGHTS MAY APPLY. SUCH RIGHTS VARY FROM STATE TO STATE.

502 INDIANA AVE, SHEBOYGAN WI 53081 USA

Toll Free Technical Support: 800-861-8758 • Technical Support: 920-451-9301

E-mail: supportspecialist@pentekfiltration.com

Phone: 920-457-9435 • International Fax: 920-457-2417

E-mail: international@pentekfiltration.com • www.pentekfiltration.com

Mfg. by Pentair Water Treatment ©2003

Made in USA

145453

Rev B 07/03

 

 

Form IBUVP-00

P/N 36101326

Image 4
Contents General Precautions Assembly Instructions SpecificationsUV Lamp Replacement Replacement Parts UVS-110UV-110 Part DescriptionUV-120 UVBB-120Warranty MaintenanceTechnical Support