1.Place pump as near to water as possible, on a firm flat, level surface.

2.To prime pump, remove fill cap (Figure 2) and fill pump casing with water. If the pump casing is not filled with water before starting, it will not begin pumping.

3.Attach suction and discharge hoses to the pump. Check that all hoses are securely attached to the pump. Make certain suction hose (Figure 2) does not have any air leakage. Tighten hose clamps and couplings as required.

4.It is recommended that 2 clamps be used when securing the suction hose to the inlet side (suction) of the pump.

5.Remember suction hoses must be rigid enough not to collapse when the pump is in operation.

6.Check that the discharge hose (Figure 2) is not restricted. Place hose so that it lays as straight as it is possible on the ground. Remove any twists or sharp bends from hose which may block the flow of water.

Suction and discharge hoses are available from Multiquip. Contact your nearest dealer for more information.

7.The discharge hose is usually a collapsible (thin- walled) hose, however if a thin-walled discharge hose is not available, a rigid suction hose can be substituted in its place.

8.Make sure the suction strainer (Figure 2) is clean and securely attached to the water end of the suction hose. The strainer is designed to protect the pump by preventing large objects from being pulled into the pump.

CAUTION — Strainer

Thestrainershouldbepositionedsoitwillremaincompletely under water. Running the pump with the strainer above water for long periods can damage the pump.

QP2H CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (08/04/08) — PAGE 17

Image 17
Contents Model QP2H Proposition 65 Warning Page QP2H Centrifugal Pump Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationHazard Symbols You can be Injured if you do not follow these directionsDo not operate or service this equipment General SafetyOperate the engine with heat shields or guards removed Equipment or engineTransporting Winter drain water from pump housing to prevent freezingLoading and Unloading Refueling Emergencies Maintenance SafetySPECIFICATIONS/DIMENSIONS Pump SPECIFICATIONS/DIMENSIONS Engine Application General InformationDrain Plug Remove this plug to drain water from the pump Pump ComponentsMuffler Used to reduce noise and emissions Basic EngineInitial Servicing Page Inspection Engine Inspection EngineSET-UP SET-UPPlace the engine fuel valve lever to the on position OperationStartingthe Engine Always run engine at full speed while pumping Stoppingthe EngineFeet of lift at sea level Maintenance PumpPumpvacuumtest Pump Vacuum Tester Engine Maintenance Maintenance EngineEngine AIR Cleaner MaintenanceDaily WeeklyPump Storage StorageEngine Troubleshooting Troubleshooting EngineEngine Troubleshooting Troubleshooting ENGINE/PUMPPage Explanation of Code in Remarks Column Sample Parts ListSuggested Spare Parts Pump Assy Adjust Liner DIA .5 Thickness Adjust Liner DIA .3 ThicknessENGINE, Honda CasingHonda GX120U1PX2 Engine AIR Cleaner Dual Assy COLLAR, AIR Cleaner GROMMET, AIR CleanerCollar B, AIR Cleaner GASKET, ElbowHonda GX120U1PX2 Engine Camshaft Assy ROD, Push SPRING, Weight ReturnARM, Valve Rocker LIFTER, ValveHonda GX120U1PX2 Engine Carburetor Assy Gasket SET PLATE, Lever SettingValve SET, Float Float SETHonda GX120U1PX2 Engine Control Assy ROD, Governor ARM, GovernorSPRING, Governor SPRING, Throttle ReturnHonda GX120U1PX2 Engine Crankcase Cover Assy GASKET, OIL Filler CAP GASKET, Case CoverBEARING, Radial Ball OIL SealHonda GX120U1PX2 Engine Crankshaft Assy CRANKSHAFT, P-TYPE 13310ZE0650Honda GX120U1PX2 Engine Cylinder Barrel Assy PIN, Governor Weight WEIGHT, GovernorSLIDER, Governor SHAFT, Governor ARMHonda GX120U1PX2 Engine Cylinder Head Assy CLIP, Valve Guide GUIDE, Valve OS OptionalGASKET, Cylinder Head COVER, HeadHonda GX120U1PX2 Engine FAN Cover Assy WIRE, Stop Switch 370MM GROMET, Adjusting CableCOVER, FAN *NH1* Black PLATE, Sideoil AlertHonda GX120U1PX2 Engine Flywheel Assy PULLEY, Starter FAN, CoolingFlywheel NUT, Special 14MMHonda GX120U1PX2 Engine Fuel Tank Assy JOINT, Fuel Tank RUBBER, Supporter 107MMTANK, Fuel *NH1* Black GASKET, Fuel Filler CAPHonda GX120U1PX2 Engine Ignition Coil Assy 30500ZE1063 Coil ASSEMBLY, Ignition30700ZE1013 90121952000Honda GX120U1PX2 Engine Muffler Assy GASKET, Muffler Muffler STDSCREW, Tapping NUT, HEX MMHonda GX120U1PX2 Engine Piston Assy Ring SET, Piston BOLT, Connecting RODPISTON, Standard PISTON, OSHonda GX120U1PX2 Engine Recoil Starter Assy CASE, Recoil Starter SCREW, SettingREEL, Recoil Starter RATCHET, StarterHonda GX120U1PX2 Engine Gasket Assy 06111ZH7405 Honda GX120U1PX2 Engine Labels Assy LABEL, Caution EmblemMARK, Choke Gray MARK, Throttle IndicationFreight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help
Related manuals
Manual 36 pages 22.69 Kb

QP2H specifications

The Multiquip QP2H is a high-performance portable generator designed to meet the power needs of both professionals and recreational users. Known for its reliability and robust design, this generator incorporates advanced technologies that ensure efficient operation, durability, and ease of use.

At the heart of the QP2H is its powerful Honda GX160 engine, which provides a maximum output of 2,000 watts. This engine is renowned for its fuel efficiency and low emissions, making it an environmentally friendly choice for users. The generator is equipped with a recoil start system that allows for easy ignition, even in challenging situations. Its lightweight and compact design make it highly portable, allowing users to transport it effortlessly to job sites, campsites, or outdoor events.

One of the standout features of the QP2H is its dual voltage capability. Users can switch between 120V and 240V output with a simple adjustment, making it versatile enough to power a variety of devices. This is particularly useful for contractors who need to run both standard tools and higher-voltage equipment. The generator also includes multiple AC outlets, providing flexibility for connecting multiple devices simultaneously.

Durability is a core characteristic of the QP2H. The generator's frame is built from strong steel, ensuring it can withstand the rigors of daily use in tough environments. It also features a protective roll cage that guards against impacts and enhances stability on uneven surfaces. The generator's design incorporates noise-reducing technology, which minimizes operational sound, making it more suitable for residential areas or noise-sensitive locations.

Another noteworthy aspect of the QP2H is its fuel tank capacity, which allows for extended run times. Users can expect up to 7 hours of continuous operation on a single tank, depending on the load. This efficiency is critical for users who need a reliable power source without the frequent interruptions of refueling.

In conclusion, the Multiquip QP2H stands out in the portable generator market due to its powerful engine, dual voltage capability, robust construction, and user-friendly design. Whether for construction sites, outdoor adventures, or emergency power backup, this generator provides the reliability and versatility needed to meet diverse power requirements. With the QP2H, users can rest assured knowing they have a dependable source of electricity wherever they go.