Johnson Controls 8000, 6000, 5000 Humidifier Specifications, Johnson Controls Unitary Products

Page 2

Humidifier Specifications

 

 

A. Unit Size

 

 

 

 

 

 

 

 

(inches)

 

 

 

 

 

 

Sizing

B. Plenum

Bypass

 

 

 

 

Humidifier

Sq. Ft. Area

 

Opening

Connection

Water Feed

Electrical

UL

Components

Type

(air changes/hr)

 

(inches)

Size

Rate

Data

Approved

Included

 

 

 

 

 

 

 

 

 

 

120V operation:

 

 

 

 

120V-60Hz:

 

Manual Humidistat,

 

750 loose (2), 1,500 average

 

 

 

 

11.5 AMP,

 

 

A.

10-1/8 W x

N/A –

 

 

Dispersion Tube,

 

(1), 3,000 tight (1/2)

N/A – Total

1.4 kW

 

8000 Series

208V operation:

 

20-7/8 H x

Dispersion

water usage

208V-60Hz:

UL

Steam Hose, Drain

 

7-1/8 D

tube mounts

Hose, Hose Clamps,

Canister

 

is output plus

Approval

1,350 loose (2), 2,650 average

 

 

through

11.5 AMP,

Blower Activation

Steam

B. N/A – Unit

approximately

certified

(1), 5,350 tight (1/2)

1-1/4” hole

2.4 kW

Relay, Installation/

Humidifier

20% for drain

by ETL

 

 

can be remote

in supply or

 

Operation &

 

240V operation:

 

cycles.

240V-60Hz:

 

 

 

mounted.

return duct.

 

Maintenance Manual,

 

1,500 loose (2), 3,050 average

 

 

11.5 AMP,

 

 

 

 

 

 

 

Owners Manual

 

(1), 6,100 tight (1/2)

 

 

 

 

2.8 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1,050 loose house (2)

A.

15-29/32 W x

 

 

 

 

Manual Humidistat

7000 Series

 

18 H x

 

 

 

 

 

 

10-11/32 D

 

 

120V-60Hz

 

Saddle Valve,

Power

2,100 average house (1)

 

N/A

6 gph

Yes

 

 

0.8 AMP

Installation Template,

Humidifier

 

B.

14-3/4 W x

 

 

 

4,200 tight house (1/2)

 

 

 

 

Owner’s Manual

 

 

 

 

 

 

 

 

14-5/16 H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.

15-3/8 W x

 

 

 

 

 

 

 

 

15-3/4 H x

 

 

 

 

 

 

1,000 loose house (2)

 

10-1/4 D

 

 

 

 

Manual Humidistat

6000 Series

 

6” dia. round

 

 

 

 

 

 

 

 

 

Saddle Valve,

 

 

 

 

24V-60Hz

 

Bypass

2,000 average house (1)

 

opening

6”

3 gph

Yes

Installation Template,

 

0.5 AMP

Humidifiers

 

 

for bypass

 

 

 

Owner’s Manual,

4,000 tight house (1/2)

 

 

 

 

 

 

 

connection

 

 

 

 

24-volt Transformer

 

 

 

 

 

 

 

 

 

B.

10 W x

 

 

 

 

 

 

 

 

12-3/4 H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.

15-3/8 W x

 

 

 

 

 

 

 

 

15-3/4 H x

 

 

 

 

 

 

1,000 loose house (2)

 

10-1/4 D

 

 

 

 

Manual Humidistat

4000 Series

 

6” dia. round

 

 

 

 

 

 

 

 

 

Saddle Valve,

Water Saver

 

 

 

 

24V-60Hz

 

2,000 average house (1)

 

opening

6”

3 gph

No

Installation Template,

Bypass

 

0.5 AMP

 

 

for bypass

 

 

 

Owner’s Manual,

Humidifiers

4,000 tight house (1/2)

 

 

 

 

 

 

connection

 

 

 

 

24-volt Transformer

 

 

 

 

 

 

 

 

 

B.

10 W x

 

 

 

 

 

 

 

 

12-3/4 H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.

15-5/8 W x

 

 

 

 

 

 

 

 

13 H x

 

 

 

 

 

 

750 loose house (2)

 

10-1/4 D

 

 

 

 

Manual Humidistat

5000 Series

 

6” dia. round

 

 

 

 

 

 

 

 

 

Saddle Valve,

 

 

 

 

24V-60Hz

 

Bypass

1,500 average house (1)

 

opening

6”

3 gph

Yes

Installation Template,

 

0.5 AMP

Humidifiers

 

 

for bypass

 

 

 

Owner’s Manual,

3,000 tight house (1/2)

 

 

 

 

 

 

 

connection

 

 

 

 

24-volt Transformer

 

 

 

 

 

 

 

 

 

B.

9-1/2 W x

 

 

 

 

 

 

 

 

9-1/2 H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Series 8000, 7000, 6000, 5000, 4000 humidifier performance based on:

a.20°F and 70% R.H. Outside Air

b.0°F and 35% R.H. Room Air

c.Internal Moisture Gain of 1 lb/hr

d.70% Blower Operation

e.8 Ft. Ceiling Height

665513-UTG-B-1211

Johnson Controls

Unitary Products

5005 York Drive, Norman, OK 73069

Johnson Controls, Unitary Products reserves the right to change specifications without notice.

Image 2
Contents Unitary Products Humidifier DimensionsJohnson Controls Humidifier Specifications Johnson Controls Unitary Products
Related manuals
Manual 7 pages 3.5 Kb

4000, 7000, 8000, 5000, 6000 specifications

Johnson Controls, a global leader in building technology and energy solutions, offers a range of advanced air handling units designed to maximize efficiency and air quality. The models 8000, 6000, 4000, 7000, and 5000 cater to diverse building complexities and climate requirements, embodying the company’s commitment to innovation and sustainability.

The Johnson Controls 8000 series stands out with its high capacity and flexibility, making it suitable for large commercial buildings and industrial applications. This series incorporates advanced microprocessor controls that optimize energy usage and enhance operational performance. It also features ECM (Electronically Commutated Motors), which improve efficiency while reducing noise levels. The modular design allows for easy customization and quick installation, catering to specific building needs.

The 6000 series is engineered for medium-sized commercial spaces, combining efficiency and affordability. Its unique design incorporates high-efficiency heat exchangers and robust insulation that reduce energy consumption while providing comfort. With a focus on intelligent controls, the 6000 series can seamlessly integrate with existing building management systems, offering real-time data and performance monitoring.

For smaller commercial applications, the 4000 series provides an effective solution without compromising on features. This unit is compact yet powerful, delivering high airflow while maintaining low energy costs. Its simple installation and maintenance procedures make it an ideal choice for businesses looking for a cost-effective air handling solution. The 4000 series also includes advanced filtration options to ensure high indoor air quality.

The 7000 series is particularly noted for its application versatility, suited for both light commercial and industrial environments. This series employs advanced technologies such as variable speed drives, which adjust motor speeds based on demand, resulting in significant energy savings. Its robust build quality and efficient thermal performance make it an enduring solution for diverse operating conditions.

Lastly, the 5000 series is designed to meet the needs of educational and healthcare facilities, where indoor air quality is paramount. This series includes HEPA filtration options and UV-C light systems to significantly reduce airborne pathogens, ensuring a safe and healthy indoor environment. Its user-friendly controls and smart technology integration provide ease of operation, enabling facility managers to maintain optimal performance with minimal effort.

In summary, Johnson Controls' air handling unit offerings encompass a range of models with advanced features, cater to various application needs, and underline the company's dedication to energy efficiency and improving indoor environments for better health and comfort.