Johnson Controls 13 SEER - GCGD installation manual Section IX Instructing the Owner, Maintenance

Page 12

1031452-UIM-B-0513

SECTION IX: INSTRUCTING THE OWNER

Assist owner with processing warranty cards and/or online registration. Review Owners Guide and provide a copy to the owner and guidance on proper operation and maintenance. Instruct the owner or the opera- tor how to start, stop and adjust temperature setting.

When applicable, instruct the owner that the compressor is equipped with a crankcase heater to prevent the migration of refrigerant to the compressor during the “OFF” cycle. The heater is energized only when the unit is not running. If the main switch is disconnected for long peri- ods of shut down, do not attempt to start the unit until 8 hours after the switch has been connected. This will allow sufficient time for all liquid refrigerant to be driven out of the compressor.

The installer should also instruct the owner on proper operation and maintenance of all other system components.

MAINTENANCE

1.Dirt should not be allowed to accumulate on the outdoor coils or other parts in the air circuit. Clean as often as necessary to keep the unit clean. Use a brush, vacuum cleaner attachment, or other suitable means.

2.The outdoor fan motor is permanently lubricated and does not require periodic oiling.

3.If the coil needs to be cleaned, use clean water to wash dust, dirt, and debris from outdoor condensing coil.

NOTICE

DO NOT use coil cleaners to clean outdoor condensing coil. cleaners containing HF-, hydroxides, chlorides, and sulfates can greatly reduce the lifetime of the aluminum condensing coil.

4.Refer to the furnace or air handler instructions for filter and blower motor maintenance.

5.The indoor coil and drain pan should be inspected and cleaned reg- ularly to prevent odors and assure proper drainage.

IT IS UNLAWFUL TO KNOWINGLY VENT, RELEASE OR DIS- CHARGE REFRIGERANT INTO THE OPEN AIR DURING REPAIR, SERVICE, MAINTENANCE OR THE FINAL DISPOSAL OF THIS UNIT.

WHEN THE SYSTEM IS FUNCTIONING PROPERLY AND THE OWNER HAS BEEN FULLY INSTRUCTED, SECURE THE OWNER’S APPROVAL.

12

Johnson Controls Unitary Products

Image 12
Contents Section II Safety List of SectionsList of Figures List of TablesSection III Unit Installation Precautions During Line Installation Precautions During Brazing of LinesPrecautions During Brazing Service Valve Liquid Line FILTER-DRIERSection IV Orifice Installation Tions During Brazing Service ValveSection V TXV Installations Section VI EvacuationSection VII System Charge Field Connections Power Wiring Section Viii Electrical ConnectionsSuperheat Charging Method Piston Indoor Subcooling Charging Method TXV IndoorField Connections Control Wiring AC 1A ThermostatID Models PSC Single Stage AIR Handler AIR ConditionerAC 1B PSC Single Stage AIR AIR Handler ConditionerAC 5A PSC Single Stage AIR Furnace AIR ConditionerAC 5B Single Stage PSC FurnaceSingle Stage AIR Conditioner Maintenance Section IX Instructing the OwnerSection X Wiring Diagram UIM-B-0513 Section XI Start UP Sheet Air Conditioning and Heating Start-Up SheetAdjust Cool

13 SEER - GCGD specifications

Johnson Controls has long been recognized as a leader in the HVAC industry, and their 13 SEER - GCGD model encapsulates the company's commitment to energy efficiency, innovation, and user comfort. The GCGD, designed for residential applications, offers a balanced combination of performance and value, making it an excellent choice for homeowners looking to enhance their indoor environment.

One of the standout features of the 13 SEER - GCGD is its Seasonal Energy Efficiency Ratio (SEER) rating of 13, which categorizes it as an energy-efficient cooling system. This rating translates to substantial energy savings when compared to older, less efficient units, allowing users to reduce both their environmental impact and utility bills. Moreover, this unit is designed to perform efficiently in a variety of weather conditions, ensuring reliable cooling throughout the peak summer months.

At the heart of the GCGD is its advanced scroll compressor, known for its quiet operation and durability. This technology minimizes noise disturbances while efficiently compressing the refrigerant to optimize cooling performance. Additionally, the unit incorporates a compact design, allowing for easier installation in tight spaces, making it suitable for various residential settings.

Another significant characteristic of the GCGD is its use of high-quality components, including a robust cabinet construction designed to withstand the elements. This ensures long-term reliability and protection against outdoor conditions, thus extending the lifespan of the unit. The use of corrosion-resistant materials further enhances durability, reducing maintenance needs and costs over time.

The GCGD also features user-friendly controls, which enable homeowners to easily set their desired temperature and operating mode. Optional smart thermostats can be integrated, providing advanced control and energy management solutions that cater to modern lifestyle requirements. This compatibility with smart technology aligns with the growing trend towards home automation, allowing homeowners to manage their comfort efficiently.

In summary, Johnson Controls' 13 SEER - GCGD model offers an appealing solution for those in search of an energy-efficient and reliable air conditioning system. With its optimal SEER rating, advanced compressor technology, robust construction, and user-friendly design, the GCGD stands out as a practical choice for households looking to enhance their cooling capability while being mindful of energy consumption. This model not only promises comfort but also contributes positively to a sustainable future.