GENERAL

YORK Model DNA units are cooling/heating air conditioners designed for outdoor installation. Only gas piping, electric power and duct connections are required at the point of installation.

The gas-fired heaters have spark to pilot ignition. The tubular heat exchangers are aluminized steel.

APPROVALS

Design certified by CGA and AGA listed as follows:

1.For use as a forced air furnace with cooling unit.

2.For outdoor installation only.

3.For installation directly on combustible flooring or, in U.S., on wood flooring or Class A; B; C roof covering material.

This appliance is not to be used for temporary heating of buildings or structures under construction.

Installer should pay particular attention to the words; NOTE, CAUTION, and WARNING. NOTES are intended to clarify or make the installation easier. CAUTIONS are given to prevent equipment damage. WARNINGS are given to alert the installer that personal injury and/or equipment damage may result if installation procedure is not handled properly.

INSPECTION

As soon as a unit is received, it should be inspected for possi- ble damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's freight bill. A separate request for inspection by the carrier's agent should be made in writing.

RENEWAL PARTS

Contact your local York® parts distribution center for autho- rized replacement parts.

4.For installation on combustible material.

5.For use with natural gas and/or propane (LP) gas. Not suitable for use with conventional venting systems.

This product must be installed in strict compliance with the enclosed installation instructions and any applicable local, state, and national codes includ- ing, but not limited to, building, electrical and mechanical codes.

Improper installation may create a condition where the operation of the product could cause personal injury or property damage.

 

 

 

 

 

 

 

D

 

2

 

N

A

 

0

3

6

 

N

 

0

3

6

 

0

6

 

 

 

 

 

PRODUCT CATEGORY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06 = 208/230-1-60

 

D = Single Package Air Conditioner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRODUCT GENERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = 2nd Generation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 = 3rd Generation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL GAS HEATING

 

 

PRODUCT IDENTIFIER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NA = 10 SEER Gas Heat/Electric

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036 = 36,000 BTUH

 

 

 

NOMINAL COOLING

 

 

 

 

 

FACTORY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

056 = 56,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY (MBH)

 

 

INSTALLED GAS HEAT

 

 

 

065 = 65,000 BTUH

 

 

 

 

 

018 = 18,000 BTUH

 

N = Natural Gas Heat Installed

 

 

 

072 = 72,000 BTUH

 

 

 

 

 

 

 

 

 

090 = 90,000 BTUH

 

 

 

 

 

024 = 24,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110 = 110,000 BTUH

 

 

 

 

 

030 = 30,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036 = 36,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042 = 42,000 BTUH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060 = 60,000 BUTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 1 - PRODUCT NOMENCLATURE

Johnson Controls Unitary Products

3

Image 3
Contents Export Affinity SeriesTable of Contents Renewal Parts GeneralApprovals InspectionLocation InstallationLimitations Unit Application DataFilters Unit Weights and Center of GravityDuct Work Roof CurbService Access Power and Control WiringThermostat PROPANE1 LP GAS Application Data Natural GAS Application DataGAS Connection Natural GAS Pipe Sizing CHART1Propane LP GAS Pipe Sizing CHART1 GAS PipingFlue Vent Outlet AIR Hood Flue Vent HoodElectrical Data Physical DataUnit Minimum CLEARANCES1 Unit Dimensions FrontUnit Dimensions Front & Bottom Heating Sequence of OperationPost Purge START-UP Manifold GAS Pressure Adjustment POST-START Check List GASPilot Instructions Checking GAS Input Adjustment of Temperature RiseChecking Supply AIR CFM Gase Rate Cubic Feet PER HOUR1DNA Coil Delta P vs Airflow Superheat Charging Table for DNA024 Superheat Charging Table for DNA030Superheat Charging Table for DNA036 Superheat Charging Table for DNA042 Superheat Charging Table for DNA048Superheat Charging Table for DNA060 XIM-A-0108 See Figure Typical Wiring Diagram NotesJohnson Controls Unitary Products York Drive Norman, OK

340968-XIM-A-0108 specifications

Johnson Controls 340968-XIM-A-0108 is a sophisticated component designed for advanced building management and automation systems. This device is engineered to enhance the performance and efficiency of HVAC (Heating, Ventilation, and Air Conditioning) systems, contributing significantly to energy conservation and optimal climate control in commercial and industrial environments.

One of the main features of the Johnson Controls 340968-XIM-A-0108 is its robust compatibility with various building management systems. This component integrates seamlessly with existing systems, allowing for quick deployment and ease of use. The flexibility of this device supports multiple communication protocols, making it a versatile choice for systems upgrades or replacements.

Another standout characteristic of the 340968-XIM-A-0108 is its advanced sensing technologies. This device is equipped with high-precision sensors that monitor temperature, humidity, and air quality, providing real-time data to the building management system. The ability to collect accurate environmental data enables facility managers to make informed decisions that enhance comfort and efficiency.

Energy efficiency is a key focus of the Johnson Controls 340968-XIM-A-0108. The device incorporates intelligent algorithms that optimize HVAC operations, significantly reducing energy consumption. By analyzing usage patterns and adjusting settings accordingly, it helps facilities decrease operational costs while maintaining ideal indoor conditions.

In addition to its operational efficiency, the Johnson Controls 340968-XIM-A-0108 features a user-friendly interface that simplifies monitoring and management. The intuitive design allows operators to easily access system data and make adjustments as necessary without requiring extensive technical knowledge. This feature enhances the overall user experience and promotes efficient building management.

Safety and reliability are also prioritized in the design of the 340968-XIM-A-0108. Built with durable materials and rigorous testing standards, it ensures long-term operation under various conditions. Furthermore, the device supports multiple fail-safes and alarms, providing peace of mind to facility managers regarding system performance and safety.

In conclusion, the Johnson Controls 340968-XIM-A-0108 stands out in the building automation market due to its compatibility, sensing technologies, energy efficiency, user-friendly interface, and reliable performance. These features make it an essential component for optimizing HVAC operations and ensuring sustainable building management practices.