GE AVX08, AVX10, AVX07 Secure the Window and Install the Window Side Gasket

Page 11

3

Install the Air Conditioner in the Window

A

Cut two pieces of adhesive back foam seal to

the height of the window opening. Remove

the backing and apply to the vertical inside edges of the window frame and the sliding window that will rest against the air conditioner. Cut one piece to the width of the window opening and apply to the top inside edge of the window frame.

Adhesive back foam seal

 

 

5

6

7

 

4

 

 

8

 

3

 

 

9

OPEN

2

 

 

10

ED

 

1

 

 

TEMP

MODE

BSlide the air conditioner onto the support platform. Be sure the side channel butts against the vertical side edge of the window frame.

CDrill two 1/8″ holes in the window channel frame through the existing holes in the bottom bar. Screw 2 type C screws through these holes.

Bottom bar

Window channel frame

NOTES:

If the air conditioner does not fit securely, remove it and readjust the leveling bolt.

Make sure the air conditioner is firmly anchored to the window channel frame.

Safety Instructions Operating Instructions Care and Cleaning Installation Instructions

4

Secure the Window and Install the Window Side Gasket

A

Attach the window stopping clips on the top

 

 

and the bottom of the window frame (sliding

clip

 

 

windows only).

Stopping

 

 

 

 

B

Cut the foam window side gasket to the

 

 

 

proper length and stuff it between the 2

 

 

 

windows.

 

 

 

5

6

7

 

4

 

 

8

 

3

 

 

9

OPEN

2

 

 

10

ED

 

1

 

 

TEMP

MODE

Window side gasket

Stopping clip

11

Troubleshooting Tips Consumer Support

Image 11
Contents Write the model and serial numbers here Model # Serial # 23-11-2111N-003 49-7413 01-01 JRSafety Precautions HOW to Connect Electricity Operating Instructions Tips Installation Instructions CareCleaning Consumer Support TroubleshootingTemp Control Mode ControlTroubleshooting Tips Consumer Support About the controls on the air conditionerAir Direction Exhaust ControlOutdoor Coils Care and cleaning of the air conditionerSafety Instructions Operating Instructions Care Air Filter Grille and CaseConsumer Support Troubleshooting Tips Preparing to install the air conditionerSafety Instructions Care and Cleaning Operating InstructionsSafety Instructions Horizontal sliding window installation instructionsOperating Instructions Care and Cleaning Consumer Instructions Care and Cleaning OperatingInstructions Read completely, then follow step-by-stepInstall the Air Conditioner in the Window Secure the Window and Install the Window Side GasketTop retainer bar Sliders Install the Air Conditioner in the Window Casement window installation instructionsNormal Operating Sounds Before You Call For Service…Problem Possible Causes What To Do What GE Will Not Cover Air Conditioner WarrantySafety Instructions Operating Instructions Care GE Will ReplaceReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website

AVX08, AVX07, AVX10 specifications

The GE AVX series, comprising the AVX07, AVX08, and AVX10 models, represents a significant advancement in automatic voltage regulation technology, catering specifically to the needs of power generation and distribution sectors. These models are engineered to ensure the stable, efficient, and reliable operation of electrical systems.

The AVX07 stands out with its compact design and robust performance. It features advanced microprocessor-based control technology, enabling precise voltage regulation and exceptional responsiveness to varying load conditions. The built-in flexible programming capabilities allow users to customize settings according to specific operational requirements. Additionally, the AVX07 includes fault detection and prevention mechanisms, supporting prolonged equipment lifespan and reducing maintenance costs.

Next in the series, the AVX08 builds upon the foundation of the AVX07, incorporating enhanced communication interfaces such as Modbus and Ethernet. These upgrades facilitate seamless integration into existing control systems, enabling real-time monitoring and management. The AVX08 also supports a broader range of input voltages and has improved overload capacity, making it suitable for more demanding applications. Its advanced alarm and event log features ensure operational transparency, assisting operators in troubleshooting and optimization of system performance.

At the top of the line, the AVX10 combines the strengths of its predecessors while introducing cutting-edge technologies aimed at maximizing system efficiency. This model supports adaptive control algorithms, which adjust operational parameters dynamically based on load fluctuations and environmental conditions. The AVX10 also offers enhanced protection features like overvoltage, undervoltage, and short-circuit protection, ensuring comprehensive safety for connected equipment. Furthermore, its user-friendly interface and display provide operators with valuable insights into system performance.

In summary, the GE AVX series—including the AVX07, AVX08, and AVX10—exhibits a range of main features and technologies designed to meet the evolving needs of modern electrical systems. Their microprocessor-based controls, customizable settings, advanced communication options, and robust safety features make them suitable for various applications, from industrial facilities to power generation plants. These models reflect GE's commitment to innovation, reliability, and energy efficiency in voltage regulation technologies, ultimately contributing to enhanced operational performance and reduced downtime. The AVX series is an impressive solution for those seeking dependable voltage regulation in today's fast-paced technological landscape.