GE Installation Guide for Air Conditioners Including ASV06

Page 11

Installation Instructions

1WINDOW REQUIREMENTS

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

Models ASQ05, ASS05, ASV05, ASQ06, ASV06 only

(See below illustration for Models ASM05, ASM06,

ASQ08 and ASV08.)

2STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.

WOOD PIECES–

WIDTH: 2

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2higher than the top of the storm window frame or the vinyl frame.

Attach securely with nails or screws provided by the installer.

13min.

22to 36

(With accordion panels)

Models ASM05, ASM06, ASQ08 and ASV08 only

(See above illustration for Models ASQ05, ASS05,

1/2higher than storm window frame

Storm window frame

1/2higher

than vinyl frame (on some windows)

Wood

Stool

Vinyl frame

ASV05, ASQ06, ASV06.)

1312min.

2412to 36

(With accordion panels)

3PREPARE AIR CONDITIONER

ARemove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail. Cut to size.

BInstall the top mounting rail with 3 or 4 type A screws (depending on the number of holes in the top mounting rail) from the outside of the case.

Top mounting

rail

Bottom mounting rail

11

Image 11
Contents Write the model and serial numbers here Model # Serial # Ge.comDo not use an adapter plug with this appliance Consumer Support Troubleshooting TipsInstallation Ge.com USE of Extension CORDS-115-Volt models onlyRemote Control Instructions Safety InstructionsFan Mode Troubleshooting Tips Consumer SupportPower Outage Recovery Feature Cool ModeConsumer Support Air Direction-Up and Down on some models Air Direction-Side-to-SideInstructions Care and cleaning of the air conditionerSafety Consumer Support Troubleshooting Tips InstallationTools YOU will Need Before YOU BeginElectrical Requirements Parts Included Installation InstructionsPrepare AIR Conditioner Window RequirementsStorm Window Requirements Install Security Bracket and Foam TOP Window Gasket Install AIR Conditioner in WindowNormal Operating Sounds Troubleshooting Tips…Operating Instructions Safety Instructions We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration GE Will Replace GE Air Conditioner WarrantyWhat Is Not Covered Real Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances WebsiteAcondicionadores de Aire Instrucciones de Operación Instalación Instrucciones de SeguridadInstrucciones Solución de problemas Apoyo al consumidor instalaciónControl remoto Instrucciones de SeguridadApoyo al Apoyo al consumidor Consumidor Dirección del aire-de lado a lado Filtro de aire Cuidado y limpieza del acondicionador de airePrecaución no Opere el Requisitos Electricos Antes DE IniciarPartes Incluidas Herramientas QUE Usted NecesitaráRequisitos DE UNA Ventana DE Tormentas Requisitos Para LA VentanaPrepare EL Acondicionador DE Aire Prepare EL Acondicionador DE AireInstale EL Acondicionador DE Aire EN LA Ventana Instrucciones de Seguridad Operación Instalación Solucionar problemasLo hace Sonidos de operación normalesNotas Solución de problemas Instrucciones de Instalación OperaciónUn año Garantía de su acondicionador de aire de GEGE reemplazará Lo que no está cubiertoPiezas y accesorios Apoyo al Consumidor Página Web de GE AppliancesSolicite una reparación Garantías ampliadas

ASS05, ASQ08, ASQ06, ASV06, ASM06 specifications

The GE ASS05, ASQ08, ASV08, ASM06, and ASQ06 are advanced power management systems designed for optimal performance and reliability in various industrial and commercial applications. These systems integrate cutting-edge technology to provide users with enhanced monitoring, control, and efficiency in managing electrical systems.

One of the standout features of the GE ASS05 is its robust data collection capabilities. It employs smart sensors that track real-time performance metrics, helping operators identify anomalies and optimize their energy consumption. The ASS05 is tailored for seamless integration with existing infrastructure, making it an ideal choice for retrofitting older systems without the need for extensive modifications.

The ASQ08 model is engineered for high-accuracy power quality monitoring. It utilizes advanced analytics to detect and analyze voltage fluctuations, harmonics, and other disturbances that can impact electrical equipment performance. This model is particularly beneficial in environments where power quality is critical, ensuring that machinery operates at peak efficiency.

The ASV08 offers a versatile configuration suited for various applications, from manufacturing plants to commercial buildings. Its modular design allows for scaling according to specific energy needs. The ASV08 also features predictive maintenance capabilities, reducing the risk of unexpected downtime by alerting operators to potential issues before they escalate.

The ASM06 is distinguished by its user-friendly interface, which supports intuitive control over complex electrical systems. It offers comprehensive reporting tools, enabling operators to generate detailed analyses of energy usage and system performance. This functionality assists businesses in making informed decisions regarding energy management and cost reduction.

Lastly, the ASQ06 brings advanced communication features to the table. This model supports various protocols, enhancing interoperability with existing systems and enabling remote monitoring capabilities. Operators can gain insights and control from anywhere, providing flexibility and improving response times to potential issues.

In summary, the GE ASS05, ASQ08, ASV08, ASM06, and ASQ06 represent a leap forward in power management technology. Their unique features, including real-time data monitoring, predictive maintenance, modular design, user-friendly interfaces, and advanced communication capabilities, empower operators to maximize efficiency, enhance reliability, and ultimately reduce costs in their energy consumption. These systems are ideal for industries seeking to modernize their electrical infrastructure while ensuring optimal performance and sustainability.