GE AKS05, AKV05 owner manual Safety Instructions Operating Instructions, Window Requirements

Page 9

Read completely; then follow step-by-step.

1

Window Requirements

These instructions are for a standard double-

hung window. You will need to modify them for

other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions below.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

1334min.

2312to 35

(With accordion panels)

1778min.

(Without accordion panels)

Safety Instructions Operating Instructions

2

Storm Window Requirements

A storm window frame will not allow the air

conditioner to tilt towards the outside and will keep

 

it from draining properly. To adjust for this, attach

 

a piece of wood to the stool.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2higher

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

than frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storm window

 

 

 

 

 

 

 

 

 

 

 

 

frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WOOD PIECES—

WIDTH: 2″

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

Installation Instructions Troubleshooting Tips Consumer Support

9

Image 9
Contents Write the model and serial numbers here Model # Serial # 49-7430 01-02 JRInstructions Operating Instructions Consumer Support Troubleshooting Tips InstallationGEAppliances.com Troubleshooting Tips Consumer SupportAbout the controls on the air conditioner Mode ControlsCooling Descriptions Temp ControlAir Direction Up and Down on some models Air Direction Side-to-Side on some modelsGrille and Case Care and cleaning of the air conditionerOutdoor Coils Air FilterPreparing to install the air conditioner Safety Instructions Operating Instructions InstallationRead these instructions completely and carefully Parts Included Window Installation InstructionsSafety Instructions Operating Instructions Window RequirementsStorm Window Requirements Remove the Air Conditioner from the Case Consumer Support TroubleshootingRemove the Shipping Block Install the Mounting Rails onto the CasePrepare the Window Install the Side Accordion PanelsAssemble the Supports Install the Supports Support Troubleshooting Tips InstallationInstall the Case in the Window InstructionsInstall the Air Conditioner in the Case Safety Instructions Operating InstructionsNormal Operating Sounds Before you call for service…We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration What Is Not Covered Air Conditioner WarrantyWe Will Replace For The PeriodParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio

AKS05, AKV05 specifications

The GE AKS05 and AKV05 represent a significant advancement in electrical control switchgear technology, designed for robust performance and enhanced operational efficiencies in various industrial settings. These models are particularly suitable for applications involving medium voltage distribution, making them ideal for industries ranging from manufacturing to renewable energy.

One of the main features of the AKS05 and AKV05 is their innovative design, allowing for a compact footprint while accommodating the extensive functionality typically required in medium voltage systems. This space-saving design not only eases installation but also minimizes the overall footprint of electrical installations, which can be crucial in environments with limited space.

The AKS05 model is equipped with advanced circuit breaker technology that ensures reliable operation under varying conditions, providing both overcurrent protection as well as short-circuit protection. This enhances system stability and reduces the risk of equipment failure, thereby boosting operational uptime. In contrast, the AKV05 is tailored for applications requiring more precise control and monitoring capabilities, featuring integrated digital communication protocols.

Both models boast a user-friendly interface that allows for easy configuration and monitoring. This is supplemented by the incorporation of smart grid technologies enabling real-time data access, remote management, and diagnostic capabilities. As industries increasingly adopt IoT solutions, the AKS05 and AKV05 are designed with compatibility in mind, facilitating seamless integration into modern industrial networks.

Another notable characteristic of these switchgear models is their adherence to international safety standards, ensuring that they provide a high level of electrical safety in diverse operational environments. The materials used for construction are aimed at enhancing durability while withstanding harsh environmental conditions, thus ensuring longevity in service.

Additionally, these switchgears are designed with sustainability in mind, promoting energy efficiency and minimizing environmental impact. They reflect GE's commitment to fostering technologies that support the transition to greener energy solutions, aligning with global efforts toward sustainability.

In summary, the GE AKS05 and AKV05 switchgear models represent cutting-edge solutions in medium voltage distribution. With their compact design, advanced protective features, digital integration, and commitment to safety and sustainability, they stand as reliable choices for a wide range of industrial applications. These technologies not only maximize efficiency but also pave the way for future advancements in electrical control systems.