Safety Instructions

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

SAFETY PRECAUTIONS

Operating Instructions

and Cleaning

This Zoneline must be properly installed in accordance with the Installation Instructions before it is used. See the Installation Instructions in the back of this manual.

Immediately repair or replace all electric service cords that have become frayed or otherwise damaged.

Unplug or disconnect the Zoneline at the fuse box or circuit breaker before making any repairs.

NOTE: We strongly recommend that any servicing be performed by a qualified individual.

Replacing an existing unit?

For details, see the Installation Instructions in this manual.

Care

Troubleshooting Tips

Customer Service

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

2

Image 2
Contents Air Conditioners Replacing an existing unit? CleaningTroubleshooting Tips Customer Service About the controls on your Zoneline Care and Cleaning To Remove the Room Cabinet Other features your Zoneline may haveSafety Instructions Troubleshooting Tips Customer Service Air DirectionAuxiliary Controls on your Zoneline Remote Thermostat-Class Care and Cleaning TipsCustomer Service Occupancy Sensor Load Shedding CDCTemperature Limiting Care and Cleaning Troubleshooting TipsAuxiliary Controls-Terminal Connections External Fan Obtained locally Care and Cleaning Remote ThermostatDoor Sensor Obtained locally Central Desk ControlRoom Cabinet and Case Care and cleaningSafety Instructions Operating Instructions Outdoor CoilsSafety Air Filters Instructions Operating InstructionsZoneline Components Before YOU BeginTools YOU will Need Installation Instructions HOW to Connect 230/208 Volt Electrical SupplyCUT and Strip the Cordset Volt Electrical SupplyRemove Junction BOX Attach Conduit Make Wiring ConnectionsReinstall Junction BOX Prepare the Room Cabinet Installing the ZonelineInstall the Wall Case Exterior Grille Install the Unit Into the Wall Case Replace the Room CabinetOptional Drain KIT Installation External DrainBefore You Call For Service… Safety Instructions Operating Instructions Care and CleaningThings that are normal Normal Operating SoundsPage Page Page General Electric Company Consumer Product Ownership Registration Zoneline Warranty GE Will ReplaceConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio
Related manuals
Manual 3 pages 19.93 Kb

2500, 3500 specifications

The GE 2500 and 3500 series gas turbines represent the industry’s benchmark for high-performance, reliable, and efficient power generation. Both models have carved a niche in various applications ranging from base load power generation to peaking and combined cycle operations, further addressing global energy demands with advanced technologies.

The GE 2500 series is known for its compact size and robustness, making it ideal for a range of industrial and utility applications. It typically features a modular design which allows for easy maintenance and upgrades, resulting in reduced downtime. The 2500 can achieve outputs ranging from 25 to 35 megawatts, providing a significant balance of power and efficiency for smaller installations.

Key technologies in the GE 2500 series include advanced combustion systems that improve efficiency while minimizing emissions. This series is equipped with DLN (Dry Low NOx) technology, which significantly reduces nitrogen oxide emissions, enabling compliance with stringent environmental regulations. The turbine employs a sophisticated digital control system for optimized performance, conversion efficiency, and real-time monitoring, ensuring reliability under various operating conditions.

On the other hand, the GE 3500 series offers a higher capacity, producing outputs of up to 200 megawatts. This series incorporates more advanced aerodynamics and materials, designed for high efficiency and reliability in large-scale power plants. The GE 3500 leverages advanced technologies such as H-class combustion systems, capable of achieving efficiencies above 61%, thereby enhancing its economic viability.

Both the 2500 and 3500 series utilize GE’s latest technologies in digital solutions, such as the Digital Wind Farm and Industrial Internet of Things (IoT) integration. These innovations provide operators with predictive analytics capabilities, enabling them to foresee maintenance needs, optimize performance, and minimize operational costs.

In terms of characteristics, both models exhibit excellent load following capabilities, making them well-suited for modern grids with variable energy sources. They also demonstrate exceptional startup times and operational flexibility, essential in addressing fluctuating energy demands.

Overall, the GE 2500 and 3500 series turbines showcase the latest advancements in power generation technology, combining efficiency, reliability, and environmental stewardship, while meeting the diverse needs of today’s energy landscape. These models represent GE's commitment to delivering innovative solutions that enhance operational performance and sustainability in the power sector.