Pelco ALM2064 manual DIP Switch

Page 13

Table A. Switch 1

SW1 – Communications/Alarm Type Selection

 

Baud

 

 

 

Alarm Range

 

 

 

Alarm Mode

 

1-32

 

33-64

 

1200

Off

Off

Off

1-64

Off

Off

Off

Norm. Open

Off

 

Off

Off

 

Off

 

 

 

 

 

 

 

 

 

(Unsupervised)

 

 

2400

On

Off

Off

65-128

On

Off

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4800

Off

On

Off

129-192

Off

On

Off

Norm. Closed

Off

 

On

Off

 

On

 

 

 

 

 

 

 

 

 

(Unsupervised)

 

 

9600

On

On

Off

193-256

On

On

Off

 

 

 

 

 

 

 

19200

Off

Off

On

257-320

Off

Off

On

Supervised

On

 

Off

On

 

Off

 

 

 

 

 

 

 

 

 

 

 

38400

On

Off

On

321-384

On

Off

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57600

Off

On

On

385-448

Off

On

On

*Default to

On

 

On

On

 

On

115200

On

On

On

449

On

On

On

Norm. Open

 

 

 

 

 

 

 

 

 

 

DIP Switch

1

2

3

 

4

5

6

 

7

 

8

9

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The alarm modes default to normally open when DIP switches 7-10 are set to an invalid condition (all On).

Table B. Switch 2

Address

 

 

 

 

SW2 – Address

 

 

 

 

1

Off

Off

Off

Off

 

Off

Off

 

Off

Off

Off

Off

2

On

Off

Off

Off

 

Off

Off

 

Off

Off

Off

Off

3

Off

On

Off

Off

 

Off

Off

 

Off

Off

Off

Off

4

On

On

Off

Off

 

Off

Off

 

Off

Off

Off

Off

5

Off

Off

On

Off

 

Off

Off

 

Off

Off

Off

Off

6

On

Off

On

Off

 

Off

Off

 

Off

Off

Off

Off

7

Off

On

On

Off

 

Off

Off

 

Off

Off

Off

Off

8

On

On

On

Off

 

Off

Off

 

Off

Off

Off

Off

9

Off

Off

Off

On

 

Off

Off

 

Off

Off

Off

Off

10

On

Off

Off

On

 

Off

Off

 

Off

Off

Off

Off

11

Off

On

Off

On

 

Off

Off

 

Off

Off

Off

Off

12

On

On

Off

On

 

Off

Off

 

Off

Off

Off

Off

13

Off

Off

On

On

 

Off

Off

 

Off

Off

Off

Off

14

On

Off

On

On

 

Off

Off

 

Off

Off

Off

Off

15

Off

On

On

On

 

Off

Off

 

Off

Off

Off

Off

16

On

On

On

On

 

Off

Off

 

Off

Off

Off

Off

DIP Switch

1

2

3

4

5

6

 

7

8

9

10

1

2

3

4

5

6

7

8

9

10

1

2

3

4

5

6

7

8

9

10

ON

ON

SERIAL PORT 1

BEGIN ALARM RANGE

BAUD RATE

1-64: OFF, OFF, OFF

1200: OFF, OFF, OFF

65-128: ON, OFF, OFF

2400: ON, OFF, OFF

129-192: OFF, ON, OFF

4800: OFF, ON , OFF

193-256: ON, ON, OFF

9600: ON, ON, OFF

257-320: OFF, OFF, ON

19200: OFF, OFF, ON

321-384: ON, OFF, ON

38400: ON, OFF, ON

385-448: OFF, ON, ON

57600: OFF, ON, ON

449: ON, ON, ON

115200: ON, ON, ON

 

N.O. = NORMALLY OPEN

N.C. = NORMALLY CLOSED

SUP = SUPERVISED

UNSUP = UNSUPERVISED

ALARM GROUP 33-64 N.O. UNSUP: OFF, OFF N.C. UNSUP: OFF, ON SUP: ON, OFF DEFAULT N.O.: ON, ON

ALARM GROUP 1-32 N.O. UNSUP: OFF, OFF N.C. UNSUP: OFF, ON SUP: ON, OFF DEFAULT N.O.: ON, ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOT USED:

 

 

 

LOCAL DEVICE ADDRESS

OFF

 

 

 

 

 

DIAGNOSTICS: OFF

DEFAULT SETTINGS: LOCAL DEVICE ADDRESS 1, DIP SWITCH 9 OFF, DIP SWITCH 10 ON

NOTE: REFER TO APPENDIX A FOR SETTING EACH DEVICE ADDRESS (1-253)

DEFAULT SETTINGS: BAUD 19200, ALARM RANGE 1-64, ALARM GROUPS N.O.

00718

Figure 13. SW1 & SW2 Functions

C1517M-A (11/02)

13

Image 13
Contents ALM2064 Contents For Qualified Service Personnel only Important Safeguards and WarningsDescription OverviewFront View Rear View of ALM2064 Rear ViewConnecting to the CM6800 InstallationMounting DIP Switch Settings for Supervised/Unsupervised Modes Wiring AlarmsSupervised Alarm Input Wiring Supervised ModeUnsupervised Alarm Input Wiring Unsupervised ModeMaking the Alarm Connections Wiring External Alarm Inputs Using Analog Circuitry Setting the DIP Switches Relay Output WiringDIP Switch Operation Problem Solution Troubleshooting= OFF = on Appendix aDIP Switch Electrical SpecificationsGeneral MechanicalRegulatory Notices Warranty and Return InformationISO9001

ALM2064 specifications

The Pelco ALM2064 is a state-of-the-art surveillance system designed to enhance security and monitoring capabilities in various environments. This advanced video surveillance solution is a part of Pelco's extensive range of high-performance cameras and accessories, catering to multiple industries, including retail, transportation, and critical infrastructure.

One of the standout features of the ALM2064 is its exceptional image quality. Equipped with a high-resolution sensor, the camera provides sharp and clear images, ensuring that even the finest details are captured effectively. With the ability to deliver high-definition video up to 1080p, users can confidently monitor areas of interest without compromising on clarity.

The ALM2064 incorporates advanced technologies such as Wide Dynamic Range (WDR) and digital noise reduction, which significantly improve image quality in challenging lighting conditions. WDR allows the camera to simultaneously capture details in both bright and dark areas of the scene, making it ideal for environments with varying light sources. Digital noise reduction minimizes graininess in low-light situations, ensuring that surveillance footage remains clear and usable.

Another crucial characteristic of the ALM2064 is its versatility in deployment. The camera supports various mounting options, including wall, ceiling, and pole mounts, allowing for flexible installation in different settings. This adaptability makes it suitable for indoor and outdoor applications, as it can easily be integrated into existing security systems.

The ALM2064 is also designed with durability in mind. Its robust housing offers protection against harsh weather conditions, making it suitable for outdoor use. With an IP66 rating, it is resistant to dust and water, ensuring reliable performance in challenging environments.

In terms of connectivity, the Pelco ALM2064 supports various protocols for seamless integration with different Video Management Systems (VMS). This compatibility enhances its usability, allowing users to centralize their surveillance operations and manage multiple camera feeds efficiently.

User-friendliness is another notable aspect of the ALM2064. The camera features an intuitive interface that simplifies setup and configuration, ensuring that users can quickly get their systems up and running. Coupled with remote access capabilities, users can monitor live feeds and recorded footage from anywhere, providing flexibility and peace of mind.

In summary, the Pelco ALM2064 represents a cutting-edge solution for video surveillance, combining advanced image quality, durability, and versatile deployment options. Whether for commercial, industrial, or public safety applications, this camera meets the demands of modern security needs with reliability and performance.