Sony CV-P12PX operation manual Usage Cautions

Page 7

USAGE CAUTIONS

Ventilate the room periodically during use, especially if using gas appliances.

Be sure to turn the unit off and disconnect the power supply cord before performing any mainte- nance or cleaning.

Do not splash or pour water directly onto the unit. Water can cause electrical shock or equipment damage.

Drainage should be performed whenever moving the air conditioner. If any water remains in the tank, it may spill out while being moved.

Remove the window panel in the event of particularly adverse weather. Extremely adverse weather may cause water to leak in through the openings.

To ensure proper drainage, the drainage hose must have no kinks or be on a different level during dehumidification mode.

The drained water may spill out into the room.

The temperature around the drainage hose must not be below freezing point when used.

Drained water may freeze inside the hose, causing water inside the unit to overflow into the room.

Do not block the exhaust air outlet with obstacles. Cooling performance may be reduced or stop completely.

NOTES ON OPERATION

• Allow 3 minutes for the compressor to restart cooling.

If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor turned off for three minutes for safety.

• In the event of a power failure during use, allow 3 minutes before restarting the unit.

After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cool- ing for about 5 minutes. Any previous settings will be canceled and the unit will return to its initial settings.

• Low temperature operation: Is your unit freezing up?

Freezing may occur when the unit is set close to 64°F in low ambient temperature conditions, especially at night.

In these conditions, a further temperature drop may cause the unit to freeze.

Setting the unit to a higher temperature will prevent it from freezing.

• Dehumidification mode increases room temperature.

The unit generates heat during dehumidification mode and the room temperature will rise. Warm air will be blown out from the Exhaust air outlet, but this is normal and does not indicate a problem with the unit.

• This air conditioner blows the warm air generated by the unit outside the room via the exhaust hose while in cool mode.

Accordingly, the same amount of air as that blown out will enter the room from outside through any openings into the room.

• When cooling operation is performed at high humidity conditions, water tank inside the unit may fre- quently become full.

When water tank inside the unit is full, the unit stops operating and TIMER, OPERATION and MEGA COOL lamps will blink. In this case, perform drainage to drain out water within the unit.

ENGLISH

E-5

Image 7
Contents CV-P12PX CV-P13PX CV-PD13PX Page English For Customer Assistance the United States Consumer Limited Warranty Points to keep in mind when using your air conditioner PrecautionsUsage Cautions Avoid direct sunlight Keep the filter cleanTurn off the air conditioner when no one is home LocationCV-P12PX / CV-P13PX IncludedFront View Part NamesRear View Remote Control Display Remote ControlAttach the window panel to the window stool Install Window PanelEnglish Install 2 rain deflectors to the outside of the window panel Adjustment panel 28~36.5 Install the window panel into the window frame Installation in a sliding sash windowAdjustment panel Window slider bracket Foam seal B 28~36.5 Foam seal a Window panel Window exhaust adapter Cut Window slider bracket 36.5~64 Foam seal B Attach the exhaust hose adapter B to the unit Installation and Removal of Exhaust HoseAttach the exhaust hose Attach the baffle to the back plate of the unit Attach the exhaust hose adapters BTo the unit Attach the exhaust hosesInstall one exhaust hose Remove the exhaust hose adapter from the unit Removal of the exhaust hosePress the Reset button until you hear another Click Power Plug CheckPRE-OPERATION Checks HOW to USE the Remote Control Dehumidification Mode Cool ModeVentilation Mode FAN ModePress the Louvers button on the re- mote control To Change AIR Flow DirectionUP / Down AIR Flow Direction Left / Right AIR Flow DirectionPress the Plasmacluster button again Plasmacluster OperationPress the Sleep button Mega Cool OperationSleep Operation Press the Mega Cool button againOn Timer Timer OperationOFF Timer Drainage Main Unit OperationReplace the stopcock to the drainpipe Maintenance After AIR Conditioner Season MaintenanceCleaning the Filter Cleaning the Unit and the Remote ControlAIR Conditioner does not Operate AT ALL Before Calling for Service

CV-P12PX specifications

The Sony CV-P12PX is a high-performance air purifier designed to enhance indoor air quality while exuding modern aesthetics suited for contemporary living spaces. Featuring an efficient HEPA filtration system, the CV-P12PX can capture up to 99.97% of airborne particles as small as 0.3 microns, including dust, pollen, smoke, and pet dander. This efficiency makes it an ideal choice for allergy sufferers or those looking to maintain a healthier environment at home.

One of the standout features of the CV-P12PX is its advanced sensing technology. It utilizes a built-in air quality sensor that continuously monitors the surrounding air, automatically adjusting the purification level based on real-time data. With a user-friendly LED indicator, users can easily track the air quality status, ensuring peace of mind regarding their respiratory health.

The CV-P12PX also boasts a powerful yet whisper-quiet motor, allowing it to function effectively without disturbing daily activities. Its multi-speed fan system offers customizable airflow settings, so users can switch between low, medium, and high modes depending on their specific needs. The sleep mode feature is particularly useful for nighttime operations, optimizing the airflow and minimizing noise levels for a restful environment.

In terms of design, the CV-P12PX sports a sleek, compact form factor that makes it easy to integrate into various home decor styles. Its lightweight construction facilitates portability, allowing users to move it effortlessly from room to room. Additionally, the filter replacement indicator is a practical feature that reminds users when it’s time to change the HEPA filter, ensuring the device runs at peak efficiency.

Energy efficiency is another critical characteristic of the CV-P12PX. It is designed to consume minimal power while maximizing performance, making it a cost-effective option for long-term use. The eco-friendly approach is further complemented by the use of recyclable materials in its construction.

In summary, the Sony CV-P12PX air purifier combines cutting-edge technology with user-friendly features to deliver superior indoor air quality. Its HEPA filtration, real-time air quality monitoring, customizable settings, and energy-efficient design make it a commendable choice for those seeking to improve their home environment and promote overall well-being. Whether placed in a bedroom, living room, or office, the CV-P12PX stands out as a reliable and stylish solution for contemporary air purification needs.