Slant/Fin B-200A Products to Avoid, Annual Service and General Maintenance, Safety Information

Page 7

7

Bobcat Model B-120A and B-200A

The combustion air supply must not be susceptible to contaminants, which may cause corrosion or other damage to the heat exchanger and components of the boiler, causing failure of these parts or unsafe operation.

Below is a list of products which must be avoided from being stored or entering the boiler room or air supply area:

PRODUCTS TO AVOID

Spray cans containing chloro/fluorocarbons

Permanent wave solutions

Chlorinated waxes/cleaners

Chlorine-based swimming pool chemicals

Calcium chloride used for thawing

Sodium chloride used for water softening

Refrigerant leaks

Paint or varnish removers

Hydrochloric acid/muriatic acid

Cements and glues

Antistatic fabric softeners used in clothes dryers

Chlorine-type bleaches, detergents and cleaning solvents found in household laundry rooms.

Adhesives used to fasten building products and other similar products.

ANNUAL SERVICE AND GENERAL MAINTENANCE

A trained and qualified service technician should perform inspection and general maintenance listed in Installation and Operating Instructions (Publication No. B-40) before each heating season and at regular intervals.

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

SAFETY AND OPERATING INSTRUCTIONS Follow the lighting instructions in this manual. These instructions are also attached to the boiler.

SAFETY INFORMATION

For Your Safety Read Before Operating

A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch: do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to turn the gas supply shut off valve. Never use tools. If the supply shut off will not turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. DO NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

5.Open the gas supply shut off valve, by turning the handle to be parallel to the gas piping. (See Figure 8).

6.Wait five (5) minutes (longer for propane) to clear out any gas, then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you don’t smell gas, go to next step.

7.Turn on all electric power to the appliance.

8.Set thermostat to desired setting.

If the appliance will not operate, follow the instructions “To Turn Off Gas to Appliance” and call your service technician or gas supplier.

To Turn Off Gas to Appliance

1.Set thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Close the gas supply shut off valve, by turning the handle to be perpendicular to the gas piping. (See Figure 8).

TURN 90˚

TO OPEN

TURN 90˚

TO CLOSE

GAS SUPPLY SHUTOFF VALVE

GAS SUPPLY SHUTOFF VALVE

IN “OPEN” POSITION

IN “CLOSED” POSITION

Figure 8.

Image 7
Contents User’s Information Manual Welcome to OUR Valued Customer User Inspection InspectionVenting and AIR Intake System Regular Inspection Vent Pipe Termination AIR Intake Do not Block Outside Wall Non-direct vent, venting through the roof Unusual Noise Condensate Removal SystemPiping Inspection System Water Pressure InspectionOperating Instructions Annual Service and General MaintenanceSafety Information Products to AvoidIntegrated Boiler Control Removing Jacket Front PanelBobcat Boiler Display Board Viewing and Changing Temperatures Blocking Errors Diagnostic Error CodesLockout Errors Error Indication CodeSLANT/FIN CORPORATION, Greenvale, N.Y Phone 516

B-200A, B-120A specifications

Slant/Fin is a recognized leader in the heating industry, particularly known for its impressive range of high-quality boilers. Among their offerings, the Slant/Fin B-120A and B-200A models stand out due to their efficiency and advanced features. These boilers are designed for residential and light commercial applications, providing reliable heating solutions for various environments.

The B-120A model boasts a robust output of 120,000 BTUs per hour, making it suitable for slightly larger homes or spaces that require significant heating capacity. In contrast, the B-200A model delivers an impressive 200,000 BTUs per hour, catering to even larger sites where consistent and powerful heating is essential. Both models are designed with high-efficiency ratings, ensuring lower energy costs and reduced environmental impact.

One of the key features of the Slant/Fin B series is the advanced cast-iron design. This construction allows for excellent thermal conductivity, providing even heating and maximizing the lifespan of the equipment. Cast iron is known for its ability to retain heat, which means that once heated, the boiler continues to produce warmth even as it cycles down, optimizing fuel usage.

The B-120A and B-200A are also equipped with an innovative electronic ignition system, enhancing their efficiency and reliability. This feature eliminates the need for a standing pilot light, leading to reduced energy usage and maintenance requirements. Both models are designed with ease of installation in mind, featuring a user-friendly layout that allows for straightforward hook-up to existing heating systems.

In terms of technology, Slant/Fin incorporates a variety of advanced components to enhance the performance of the B-120A and B-200A models. They feature multi-functional control systems that allow users to program their heating needs efficiently. Furthermore, the boilers come with an integrated pump that optimizes system operation and supports efficient water circulation, ensuring that heat is distributed evenly throughout the space.

Another characteristic appreciated by users is the noise level; both models operate quietly, minimizing disruption in residential environments. The maintenance of these boilers is also simplified due to their design, with accessible components allowing for easy servicing and cleaning.

In conclusion, the Slant/Fin B-120A and B-200A boilers exemplify a blend of efficiency, durability, and advanced technology. With their robust heating capacity, user-friendly features, and ease of maintenance, these models are an excellent choice for anyone looking to invest in reliable heating solutions for their home or light commercial space.