4 HOW TO CLEAN FILTER; Fig. 4
| Before opening ENCLOSURE | |
CAUTION | ||
disconnect AC power supply. |
1.Remove ENCLOSURE COVER.
2.Close SUPPLY STOP (5) with 4mm Hex wrench. Note: Keep water flowing out of faucet while shutting off.
3.Pull off Red (1) and Black (2) CONNECTORS from SOLENOID VALVE (3).
4.Unthread STRAINER (4) using a 7/16" socket.
5.Pull out the STRAINER (4) and clean with an old toothbrush. Rinse thoroughly with water.
6.Install the STRAINER (4) back in its place and tighten with a 7/16" socket.
Caution: do not over tighten strainer.
Note: It is recommended to clean strainer every 6 months.
7.Replace ENCLOSURE COVER. Tighten cover screws firmly.
5HOW TO CLEAN AND REMOVE THE AERATOR; Fig. 5
1.Remove AERATOR HOUSING (1) with KEY supplied with faucet.
3.Remove AERATOR (2) from HOUSING (1).
2.Clean the AERATOR SCREENS (3) with a old tooth brush to remove dirt.
4.Rinse Clean with water. Reassemble and install into spout end. Be sure black seal washer is in place.
6 GENERAL CLEANING; Fig. 6
1.For general cleaning use a damp, soft cloth to clean the spout and the sensor.
2.For cleaning dirt use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth.
CAUTION
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout surface. Never use polishing power, detergent or a nylon scrub brush. They will damage the surface of the spout or Sensor.
Fig.4
3
4
CLEAN
SCREENS
2 | 1 | 5 | 4 |
|
|
Fig.5
1
3
2
8