Stovax installation instructions Installation, Fitting Cast front panel 8901 / 8902, Safety

Page 1

INSTALLATION

Fitting Cast front panel (8901 / 8902 / 8903)

Ensure that the floor of the fireplace opening is level with the projecting hearth surface. If a cement infill is required to achieve this, do not proceed with the installation until the cement is completely dry.

Cover the surface of the hearth to protect it from damage during installation of the cast panel.

Protect the surfaces of the surround (mantelpiece) from damage when trial fitting of the panel.

Position the front panel centrally in the fireplace opening against the wall. Place the surround (mantelpiece) in position and, holding it firmly against the wall, pull the front panel forward until it touches the rear of the surround. The panel is now in the correct position and should be fixed. The surround can be removed while this is completed.

There are a number of ways of fixing the front panel, but a typical method is:-

Drill through the 4 corners of the main panel in a position that will be covered when the surround is in position. Drill holes in the wall in corresponding position, and secure the front panel with 75mm (3”) screws and non-plastic wall plugs. Fill any gaps between the wall and the panel with a non-combustible material, such as fibreglass rope seal or Stovax fire cement, to form airtight seal.

Never use strong Portland cement mortar in chimneys and fireplaces. A lime based mortar will allow expansion and movement and reduce the risk of cracking.

Wait until any cement or seals are dry before fitting a wooden surround. If the surround is wood, fix Stovax flat rope seal (Part No. 4953) to all surfaces that touch the cast iron panel. Place it into position ensuring that it is central, and secure it to the wall using flat brass brackets (mirror plates).

With Solid fuel fires use only at a low fire for the first few hours of use to allow the castings to temper.

During this time the fireplace may give off some unpleasant odours, and we recommend that you keep the room well ventilated to avoid a build-up of fumes.

Safety

As with all fireplaces the surfaces will become very hot when in use, therefore due care should be taken when near the fireplace. If it is to be used in the presence of young children, elderly or infirm persons a suitable fireguard should be used. Care should also be taken with the placement of combustible items near the fireplace as conducted and radiated heat could cause a fire hazard.

Stovax offer a wide range of firescreens and sparkguards, along with a hearthgate system designed to offer full protection for a range of stoves and fireplaces. Your Stovax dealer can advise you on these products.

If a chimney fire occurs evacuate all persons from the building before calling the fire brigade. Do not re-enter the building until it is confirmed safe to do so.

Following a chimney fire do not use the fireplace until it is inspected, by a HETAS (GB only) registered installer, to confirm that the appliance is safe to use, or make any repairs required before re-use. Only genuine Stovax replacement parts are to be used to keep your fireplace in safe and efficient working order. After any chimney fire it is recommended that the chimney system be inspected and swept by a NACS registered (UK only) chimney sweep, to confirm that the system is structurally sound and free from any obstructions before re-use.

MAINTENANCE

For fully polished fireplaces Stovax Steel Cleaner (Part No. 2037) is recommended to keep them clean and rust free. If a fire is not to be lit for an extended period, it is advisable to coat with a light oil to prevent moisture in the air causing surface rust and pitting of the cast iron. This is important when plastering or other decorating work is being done.

E & OE.

Cast Iron

London Fronts

Models: 8901, 8902, 8903, 8904

Installation Instructions

This product is suitable for use in the stated countries. To install the product in other countries it is essential to obtain translated instructions

and in some cases the product may require modification. Contact Stovax to obtain further information.

Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF

Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.com

IMPORTANT

Please read these instructions carefully before using the appliance.

Keep them safe for future reference and when servicing the stove.

PM190-Issue 1 (October 2006)

Image 1
Contents Safety InstallationFitting Cast front panel 8901 / 8902 Models 8901, 8902, 8903Site Requirements / Installation

8904, 8902, 8901, 8903 specifications

The Stovax range of gas stoves, including the 8904, 8903, 8901, and 8902 models, represents the pinnacle of modern heating technology combined with aesthetic excellence. These stoves are designed to provide both warmth and ambiance while ensuring maximum efficiency and minimal environmental impact.

One of the main features of the Stovax 8900 series is their high efficiency rating. All models are engineered to produce a significant amount of heat while consuming less gas, making them economically advantageous for consumers looking to lower their energy bills. The stoves achieve high combustion efficiency, meaning more heat is generated from the fuel consumed.

The aesthetic versatility of the Stovax stoves is another distinctive characteristic. The 8904, 8903, 8902, and 8901 models come in various finishes, including classic black, contemporary steel, and more traditional styles, allowing homeowners to select a design that complements their interior decor. Furthermore, these stoves have a range of options for door finishes and handle styles, adding a personal touch to the installation.

In addition to their appearance, each stove in the 8900 series incorporates advanced technologies that enhance user experience and safety. The intelligent air control system allows for effortless regulation of the flame height and temperature, providing both convenience and effectiveness, whether it's a cozy evening or a chilly winter day. The unique burner system ensures even heat distribution throughout the room, enhancing comfort levels.

Safety is paramount in Stovax's design philosophy, and the 8900 series does not disappoint. Each model is equipped with robust safety features, such as a flame supervision device and an automatic shut-off option, providing peace of mind for users. The stoves also have a ceramic burner that ensures a cleaner burn, reducing emissions and contributing to a healthier environment.

The compatibility of these stoves with various flue systems offers flexibility in installation. Whether vented through a wall or into a traditional chimney, the Stovax 8900 series can be adapted to fit a range of home configurations, making them an ideal choice for many.

In conclusion, the Stovax 8904, 8903, 8901, and 8902 gas stoves combine energy efficiency, aesthetic appeal, and advanced technologies, making them excellent choices for anyone looking to enhance their home's heating while contributing to a sustainable future. With their safety features, customizable appearances, and superior performance, these stoves are a reliable and stylish heating solution for modern living.