NEC RIH-3267, RIH-2667 Location for Installing Indoor Unit, Location for Installing Outdoor Unit

Page 18

Installation instructions

Location for Installing Indoor Unit

Where there is no obstacle near the air outlet and air can be easily blown to every corner.

Where piping and wall hole can be easily arranged.

Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page.

Where the air filter can be easily removed.

Keep the unit and remote controller 1m or more apart from television, radio etc.

To prevent the effects of a fluorescent lamps, keep as far as possible.

Do not put anything near the air inlet to obstruct it from air absorption.

Where there is strong enough to bear the weight

and is not tend to increase operation noise and vibration.

Location for Installing Outdoor Unit

Where it is convenient to install and well ventilated.

Avoid installing it where flammable gas could leak.

Keep the required distance apart from the wall.

The distance between Indoor and outdoor unit should be 5 meters and can go up to maximum 15 meters with additional refrigerant charge.

Keep the outdoor unit away from a place of greasy dirt, vulcanization gas exit.

Avoid installing it at the roadside where there is a risk of muddy water.

A fixed base where is not subject to increasing operation noise.

Where there is not any blockage for air outlet.

Indoor unit

Pipe length is 15 meters Max.

Outdoor unit

Outdoor unit

Pipe length is 15 meters Max.

Indoor unit

16

PDF created with pdfFactory Pro trial version www.pdffactory.com

Image 18
Contents RIH-2667 RIH-3267 Use and Care Manual Auto Restart Presetting Preparation before useSafety precautions Identification of parts Indoor unit Outdoor unitUH series operating and display Timer Indicator Run IndicatorCompressor indicator Temperature display Sleep Indicator Remote controller Remote controllerIndication symbols on LCD How to Use How to Insert the BatteriesStorage and Tips for Using the Remote Controller Choose Cooling Only Remote controller or Heat PumpOperation instructions Operation modesAirflow direction control Airflow direction controlSmart mode Your feeling Button Adjustment procedure Slightly warmerSlightly cooler Timer mode Timer-settingSleep mode Super modeClean and reinstall the air filter MaintenanceCut off the power supply Close the front panel againProtection Protective device will work at following casesTroubleshooting Trouble AnalysisInstallation instructions Installation diagramLocation for Installing Indoor Unit Location for Installing Outdoor UnitIndoor Unit Piping Installation Indoor unit installationInstalling the Mounting Plate Drill a Hole for PipingPiping Thermal Insulation Piping ConnectionModel Pipe size Torque Nut width Min.thickness Outdoor Unit Connecting of the Cable Indoor UnitCapacity Btu/h Power cord Power connecting cord Type Indoor unit Outdoor unitOutdoor unit Indoor unit Outdoor unit installation Air purgingVacuum pump How to Purge Air Tubes ABN 86 001 217

RIH-2667, RIH-3267 specifications

The NEC RIH-2667 and RIH-3267 are advanced communication terminals designed to enhance connectivity in various environments, from corporate offices to remote locations. These devices are a product of NEC's commitment to delivering high-performance technology solutions.

The RIH-2667 is known for its robust and user-friendly design. It features a wide array of communication protocols, which makes it compatible with existing network infrastructures. This adaptability is crucial for businesses aiming to implement seamless integration across various devices. The terminal supports both wired and wireless connections, ensuring reliable communication regardless of the setting.

On the other hand, the RIH-3267 builds on the strengths of the RIH-2667, offering enhanced processing capabilities and agility. One of its main features is the support for high-speed data transmission, utilizing advanced algorithms for data optimization. It employs the latest telecommunications standards, enabling efficient handling of large volumes of data while maintaining a stable connection.

Both models are equipped with state-of-the-art security technologies, ensuring that communications remain confidential and secure. With features like end-to-end encryption and secure access protocols, they address the growing concerns of data privacy in today’s digital age.

The user interface of the RIH-2667 and RIH-3267 is intuitive, allowing for easy access to vital functions and settings. They come with customizable options for users, granting flexibility in terms of configuration and operation. This adaptability is particularly beneficial for organizations that require tailored solutions to meet specific operational demands.

In terms of physical characteristics, both devices are designed to be compact and lightweight, making them ideal for deployment in various locations without requiring significant space. Their rugged construction ensures durability, allowing them to withstand challenging environmental conditions.

Another noteworthy aspect is the customer support and maintenance services provided by NEC. The company offers comprehensive support programs, ensuring that users receive timely assistance, which is crucial for maintaining operational efficiency.

In conclusion, the NEC RIH-2667 and RIH-3267 are distinguished models in the field of communication technology. Their innovative features, robust security systems, and flexible configurations make them suitable for a wide range of applications. Organizations looking to enhance their communication capabilities will find these devices to be invaluable assets in achieving their strategic objectives.