High-speed Ionization
A Unique Structure Provides a Uniform Airflow
The newly developed airflow control system (AFCS) structure optimally controls the airflow of the fan to efficiently carry the discharged ions to the target workpiece. This gives the
Even with the airflow at a low setting, ionization is completed in approximately 2 seconds. Small, light workpieces are not blown away by the airflow, and static electricity is effectively neutralized.
Airflow Control System (AFCS)
Engineering Data
Airflow vs. Ionization Time
3 |
Conventional ZJ-FA20
| The front louvers and |
The airflow is dispersed, | internal structure keep |
lowering efficiency. | the airflow uniform. |
Ionization Area vs. Ionization Time
300
4 s
Adjustment |
dial setting |
2.5 |
MIN:1 |
200
3 s
2 s
1 s
| 2 |
|
|
|
|
|
|
(s) |
|
|
| 2 |
|
|
|
|
|
|
|
|
|
| |
time | 1.5 |
|
|
| 3 |
|
|
|
|
| 4 |
|
| ||
Ionization |
|
|
|
|
|
| |
1 |
|
|
|
| MAX: 5 |
| |
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
| 0.5 |
|
|
|
|
|
|
| 0 | 0.8 | 1.0 | 1.3 | 1.5 | 1.8 | 2.0 |
| 0.5 |
Airflow (m/s)
Measurement Conditions
Installation distance: 300 mm
Ionization time: ±1,000 V to ±100 V
Plate monitor: 150 X 150 mm, 20 pF
100 |
|
|
|
|
0 |
|
|
|
|
|
|
|
| |
|
|
|
| |
200 | 400 | 600 | 800 | |
0 | ||||
(mm) | Distance direction |
|
| (mm) |
|
|
|
|
Measurement Conditions
Airflow: Max.
Ionization time: ±1,000 V to ±100 V
Plate monitor: 150 X 150 mm, 20 pF