NOTE: In cases where long runs of gas supply lineshave been installed ahead of the appliance, it may be necessary to bleed trapped air out of the supply lines before lighting the burner. New installations generally require bleeding of supply lines. Wait a minimum of five minutes after bleeding the supply lines before attempting to light the heater.
6.IMPORTANT: DO NOT attempt to adjust the main burner input using the main gas supply valve, for this may cause the thermocouple to shut down the burner.
Shut-down instructions:
To turn the heater OFF:
1.Close the
2.Observe the burner until flame is extinguished.
3.Listen for closure of the safety valve.
4.IMPORTANT: DO NOT
MAINTENANCEINSTRUCTIONS
This heater (including hose and regulator assembly) must be inspected before each use. If the hose for Model
The appliance area must be kept free and clear of combustible materials, gasoline and other flammable vapors and liquids at all times.
The flow of combustion and ventilation air must not be obstructed.
Cleaning the heater:
Periodically, the heater must be cleaned of all dirt and dust particles.
DANGER
DONOTATTEMPTTOCLEANTHEHEATER WHILEITISOPERATINGORWHILEITIS STILLHOT.
•Turn the heater off and wait until it has completely cooled (at least 20 minutes) before cleaning.
•Clean the outside of the heater using a damp cloth. DO NOT clean the heater by spraying water on it. Wipe the outside of the heater off with a dry cloth after cleaning.
•Clean the inside of the heater using compressed air. Blow air back and forth along the entire burner face until all dust has been dislodged from the surface of the reverberator and grid screen. Blow through venturi from the control end of the heater.
•Clean the orifice of each burner with a #55 drill bit (for
•Clean the thermocouple lead.
DO NOT operate this heater if any part has been under water. Call a qualified service person to inspect the appliance and to replace any part of the control system or gas control valve which has been under water.
This heater must be inspected at least annually by a qualified service person.
TROUBLESHOOTING INFORMATION: (Model 35-R)
If burner lights, but goes out when button is released.
CHECK
•Loose wires on tipover switch. (see Fig. 4)
•Loose lead wire and repair wires if necessary.
•Loose thermocouple and tighten if necessary. Make sure T/C is located correctly between the reverberator and grid.
•Defective thermocouple. Replace if necessary.
•Defective control. Replace if necessary.
•Defective tip over switch. Replace if necessary.
Expanded Metal Screen |
|
| Cylinder |
Burner Face | Gas Valve |
| |
| Propane |
Reflector | Gas |
| Cylinder |
Thermocouple |
| |
Orifice |
| Regulator |
|
| |
Control |
| |
Valve |
| |
Reet | Hose | |
| ||
Button |
|
NOTE: WHEN LIGHTING BURNER WITH A MATCH OR TAPER, LIGHT AT BOTTOM OF SCREEN. (NOT AT ORIFICE)
Figure 3
6 | Operating Instructions and Owner’s Manual |