Hunter Fan 44029-01, 30836 owner manual Check or Replace Your Filter, Replace The UVC Bulb

Page 8

5.If the Pre-Filter needs to be cleaned, It may be submerged in warm soapy water to clean. Gently lift and submerge the filter several times to clean.

6.When complete, rinse the filter with warm water and allow to dry completely.

Note: Wet parts placed into the unit can cause damage to the filters and or the motor of the Air Purifier.

Check or Replace Your Filter

1.Turn the Air Purifier off and disconnect from the wall.

2.Remove the rear grill on the back of the unit by pressing the tab at the top of the unit, under the handle and pull the rear grill outward. Figure 7.

3.Remove the HEPA Filter from the unit.

4.Check the Filter for particle build-up.

5.The HEPA filter should be removed every 12 months of use and matched to the color indicator on the inside of the filter compartment. When the filter matches the dark, charcoal gray indicator, it should be replaced.

Replace The UVC Bulb

The UVC light should be replaced once yearly. Follow these instructions to remove and replace the UVC bulb.

1.Unplug the unit from the wall outlet and turn it over, so the bottom of the unit is visible.

2.Using a small phillips screwdriver remove the 2 screws holding the UVC Cover in place. Figure 9.

3.Gently push the tab on the UVC Cover and lift it away. Figures 9. and 10.

4.Locate the UVC Bulb Carrier and turn it 45o counter- clockwise. Figure 11.

Screws

Tab

Figure 9.

Figure 10.

Figure 11.

©2009 Hunter Fan Co.

8

44029-01 20091215

Image 8
Contents Total Air Purification Table of Contents Safety Instructions IntroductionPage Setting Up Your Air Purifier How The System Works Operating Your Air Purifier Air Purifier MaintenanceCheck or Clean Your Pre-Filter Check or Replace Your Filter Replace The UVC BulbClean the Unit Lift the UVC Bulb Carrier out of the unit. FigureTroubleshooting Technical SupportWarranty Filter OrderingPart# Type Price ProductsHunter Fan Co 44029-01 Page Filter and UVC Calendar