Lightolier FP28UDA Candlepower Summary, Coefficients of Utilization, Zonal Lumens and Percentages

Page 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BrisaLinear Planar Surface Mount  FP28UDA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall/Ceiling Mount T5 Fluorescent, ADA Compliant

FP28U / FPA3

100

200

300

90°

60°

DECORATIVE LUMINAIRE CAT. # FP28U / FPA3 28W SYLVANIA T-5 LAMPS. LUMEN RATING = 2610 LMS. BALLAST/ ADVANCE ICN-2S28

 

 

Candlepower Summary

 

Angle

Along

22.5.

45

67.5

Across.

LumensOutput

0

351

351

351

351

351

 

5

351

350

349

349

347

33

15

340

338

338

340

338

96

25

316

317

320

323

321

148

35

284

286

291

296

295

182

45

242

247

256

264

263

197

55

193

201

213

220

221

188

65

137

147

160

167

169

155

75

76

86

98

104

105

101

85

19

29

41

47

49

44

90

6

16

27

32

33

 

95

7

17

27

32

33

27

105

10

18

31

40

43

30

115

10

17

30

41

45

29

125

10

18

27

37

41

24

135

9

14

21

30

33

17

145

8

11

18

21

22

10

155

7

8

12

16

18

6

165

6

7

8

9

11

2

Coefficients of Utilization

Ceiling

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

Wall

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

.57

.57 .57

.57

.56

.56 .56 .56

.52

52

.52

.48 .48 .48 .45

.45 .45 .44

 

1

.52

.50 .48

.46

.50

.48 .46 .45

.45

.44

.42 .42 .41 .40 .40

.39 .38 .36

 

2

.48

.44 .40

.37

.46

.42 .39 .36

.39

.37

.35

.37 .35 .33

.35

.33 .32 .30

Ratio

3

.43

.38 .34

.31

.42

.37 .33

.30

.35

.32

.29

.33

.30

.28

.31

.29

.27 .26

4

.40

.34 .29 .26 .38

.33 .29 .26

.31

.27

.25

.29

.26

.24

.27

.25 .23 .22

Cavity

5

.36 .30 .25

.22

.35

.29 .25

.22

.27

.24

.21

.26

.23

.20

.24

.22

.19

.18

6

.33

.27 .22

.19

.32

.26 .22

.19

.24

.21

.18

.23 .20 .17

.22

.19

.17

.16

 

Room

7

.30

.24 .19

.16

.29

.23 .19

.16

.22

.18

.16

.21

.17

 

.15

.20

.17

.15

.14

8

.28

.21 .17

.14

.27

.21 .17

.14

.20

.16

.13

.19

.15

.13

.18

.15

.13

.12

 

 

9

.26

.19

.15

.12

.25

.19

.15

.12

.18

.14

.12

.17

.13

.11

.16

.13

.11

.10

 

10

.24

.17

.13

.11

.23

.17

.13

.11

.16

.13

.10

.15

.12

 

.10

.14

.12

.10

.09

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 32.0

400

30°

175

8

8

7

6

5

1

180

7

7

7

7

7

 

Zonal Lumens and Percentages

Zone

Lumens

% Lamp

%Luminaire

0-30

276

10.60

21.47

0-40

459

17.59

35.61

0-60

844

32.34

65.47

0-90

1144

43.84

88.75

40-90

685

26.25

53.14

60-90

300

11.50

23.28

90-180

145

5.56

11.25

0-180

1289

49.40

100.00

** Efficiency = 49.4% **

Certified Test Report no.3648FR Computed by LSI Program **TEST-LITE** SC = 1.3

Prepared For:

Lightolier

Fall River, MA

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

Job Information

Type:

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group •A0408

Lightolier is a Philips group brand

Image 2
Contents Electrical FeaturesCatalog No Description Lamping by othersZonal Lumens and Percentages Candlepower SummaryCoefficients of Utilization