Lightolier EC1-3 specifications Lamp Ordering Information, Wattage

Page 3

Lighting Systems EC1-3

Page 3 of 3

 

Energos Control System 3-Light T8 per 4' (121.92cm) (Nominal) Louver

 

Ballast Ordering Information

 

 

Lamp Ordering Information

 

Design

Lamp Type

Ballast Factor

Start Type

THD %

Design

Lamp Type

Wattage

Rated Output

Color (K)

(Lumens)

 

 

 

 

 

 

 

 

 

D

T8

0.71

Program

<10

A

T8

28

2725

3000

E

T8

0.88

Program

<10

B

T8

28

2725

3500

H

Dim T8

1.00/.05

Program

<10

C

T8

28

2725

4100

 

 

 

 

 

D

T8

30

2850

3000

 

 

 

 

 

E

T8

30

2850

3500

 

 

 

 

 

F

T8

30

2850

4100

 

 

 

 

 

G

T8

32

3000

3000

 

 

 

 

 

H

T8

32

3000

3500

 

 

 

 

 

I

T8

32

3000

4100

 

 

 

 

 

J

T8

32

3100

3000

 

 

 

 

 

K

T8

32

3100

3500

 

 

 

 

 

L

T8

32

3150

4100

Lamp and Ballast System Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp Type

 

Ballast

 

Ballast

 

Lamp Rated

 

Lamp

 

Lamp

 

IES Output

 

System

 

System

 

System

 

Start

 

 

 

 

 

 

 

 

 

 

 

Design

 

 

 

 

Rated

 

Color

 

 

Input

 

Efficacy

 

Lamp Life

 

(T8 or T5)

 

Factor (BF)

 

THD (%)

 

Wattage

 

 

 

(lumens)

 

 

 

 

Type

 

 

 

 

 

Output

 

(Kelvin)

 

 

Watts

 

(lum/watt)

 

(Hours)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DA

T8

 

0.71

 

<10

 

28

 

2725

 

3000

 

2199

 

20.0

 

96.74

 

24000

 

Program

DB

T8

 

0.71

 

<10

 

28

 

2725

 

3500

 

2199

 

20.0

 

96.74

 

24000

 

Program

DC

T8

 

0.71

 

<10

 

28

 

2725

 

4100

 

2199

 

20.0

 

96.74

 

24000

 

Program

DD

T8

 

0.71

 

<10

 

30

 

2850

 

3000

 

2299

 

21.5

 

94.12

 

24000

 

Program

DE

T8

 

0.71

 

<10

 

30

 

2850

 

3500

 

2299

 

21.5

 

94.12

 

24000

 

Program

DF

T8

 

0.71

 

<10

 

30

 

2850

 

4100

 

2299

 

21.5

 

94.12

 

24000

 

Program

DG

T8

 

0.71

 

<10

 

32

 

3000

 

3000

 

2420

 

23.0

 

92.61

 

24000

 

Program

DH

T8

 

0.71

 

<10

 

32

 

3000

 

3500

 

2420

 

23.0

 

92.61

 

24000

 

Program

DI

T8

 

0.71

 

<10

 

32

 

3000

 

4100

 

2420

 

23.0

 

92.61

 

24000

 

Program

DJ

T8

 

0.71

 

<10

 

32

 

3100

 

3000

 

2501

 

23.0

 

95.70

 

30000

 

Program

DK

T8

 

0.71

 

<10

 

32

 

3100

 

3500

 

2501

 

23.0

 

95.70

 

30000

 

Program

DL

T8

 

0.71

 

<10

 

32

 

3150

 

4100

 

2541

 

23.0

 

97.24

 

30000

 

Program

EA

T8

 

0.88

 

<10

 

28

 

2725

 

3000

 

2725

 

25.5

 

94.04

 

24000

 

Program

EB

T8

 

0.88

 

<10

 

28

 

2725

 

3500

 

2725

 

25.5

 

94.04

 

24000

 

Program

EC

T8

 

0.88

 

<10

 

28

 

2725

 

4100

 

2725

 

25.5

 

94.04

 

24000

 

Program

ED

T8

 

0.88

 

<10

 

30

 

2850

 

3000

 

2850

 

27.5

 

91.20

 

24000

 

Program

EE

T8

 

0.88

 

<10

 

30

 

2850

 

3500

 

2850

 

27.5

 

91.20

 

24000

 

Program

EF

T8

 

0.88

 

<10

 

30

 

2850

 

4100

 

2850

 

27.5

 

91.20

 

24000

 

Program

EG

T8

 

0.88

 

<10

 

32

 

3000

 

3000

 

3000

 

29.0

 

91.03

 

24000

 

Program

EH

T8

 

0.88

 

<10

 

32

 

3000

 

3500

 

3000

 

29.0

 

91.03

 

24000

 

Program

EI

T8

 

0.88

 

<10

 

32

 

3000

 

4100

 

3000

 

29.0

 

91.03

 

24000

 

Program

EJ

T8

 

0.88

 

<10

 

32

 

3100

 

3000

 

3100

 

29.0

 

94.07

 

24000

 

Program

EK

T8

 

0.88

 

<10

 

32

 

3100

 

3500

 

3100

 

29.0

 

94.07

 

24000

 

Program

EL

T8

 

0.88

 

<10

 

32

 

3150

 

4100

 

3150

 

29.0

 

95.59

 

24000

 

Program

HG

T8 DIM

 

1.0 / 0.5

 

<10

 

32

 

2850

 

3000

 

2850 / 143

 

34 / 8

 

83.80

 

NA

 

Program

HH

T8 DIM

 

1.0 / 0.5

 

<10

 

32

 

2850

 

3500

 

2850 / 143

 

34 / 8

 

83.80

 

NA

 

Program

HI

T8 DIM

 

1.0 / 0.5

 

<10

 

32

 

2850

 

4100

 

2850 / 143

 

34 / 8

 

83.80

 

NA

 

Program

*25°C Rating

All data is per 1 lamp on a two lamp system at 277 VAC. Data is based on Osram Sylvania specifications.

When ordering no lamps provided by Lightolier, use lamp code “Z”.

Do not alter lumen values or ballast factor light losses when completing calculations using Energos IES files. Files have already been adjusted. The lumen value for the lamp (within a Lighting Design program) will be the IES Ouput value shown on this table.

The lamp life table demonstrates the effects of shortened cycle-times with both program start and instant start ballasts. The graph shows that instant ballasts are susceptible to shortened lamp life if short cycle periods of less than 3 hours are used. For cycle periods of greater than 3 hours program start ballast are not required.

Lamp Life Table using program start and instant start ballasts.

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • C0808

Image 3
Contents Occupancy Sensors Feature Specifications ElectricalCoverage Diameter MountingsControl Ordering Information Ordering InstructionsECS Sensor Sample Runs ECS End Sets Wattage Lamp Ordering Information

EC1-3 specifications

The Lightolier EC1-3 is a state-of-the-art lighting solution that combines modern technology with functional design to enhance various environments. This versatile fixture is well-suited for both residential and commercial applications, making it an ideal choice for architects, designers, and homeowners looking for an efficient yet aesthetically pleasing lighting option.

One of the standout features of the Lightolier EC1-3 is its energy efficiency. Utilizing LED technology, this fixture ensures substantial energy savings compared to traditional incandescent or fluorescent lighting. With a prolonged lifespan, LEDs reduce the need for frequent replacements, ultimately lowering maintenance costs and environmental impact.

The EC1-3’s design is characterized by its slim profile and contemporary aesthetic, allowing it to seamlessly blend into any setting. It is available in various finishes, providing flexibility to match different interior styles. The fixture is designed for easy installation, featuring a user-friendly mounting system which simplifies the process for both professionals and DIY enthusiasts.

In terms of output, the EC1-3 is equipped with adjustable lumens, enabling users to customize the lighting intensity to fit specific needs. This feature is particularly beneficial in areas with varying light requirements, such as hallways, workspaces, or reading nooks. Additionally, the fixture includes dimming capabilities, giving users greater control over the ambiance of their environment.

Another advanced characteristic of the Lightolier EC1-3 is its compatibility with smart home technology. Users can integrate the fixture with existing smart systems, allowing for remote control and scheduling via mobile devices or voice commands. This technological integration not only enhances convenience but also allows for energy monitoring, leading to further savings.

Furthermore, the EC1-3 is designed with an emphasis on sustainability. The materials used in its construction are eco-friendly, and its energy-efficient operation aligns with current trends toward greener living spaces. The fixture meets various industry standards for safety and performance, ensuring reliable operation in a variety of applications.

In summary, the Lightolier EC1-3 is an exceptional lighting fixture that emphasizes energy efficiency, stylish design, and advanced technology. Its customizable features and smart compatibility make it a preferred choice for those looking to illuminate their spaces effectively while being mindful of energy consumption and environmental impact. Whether for home or business, the EC1-3 promises to deliver both functionality and elegance.