| Lighting Systems |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
Page 1 of 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Energos Control System |
Feature Specifications – Energos Control System (For standard Energos fixtures consult appropriate EG spec sheets)
Feature Specifications
Electrical
Dedicated low voltage (24 VDC) circuit controls the Energos Control Systems. The line voltage circuits control all the standard ballast functions including A/B switch- ing, Dimming and Emergency Battery Pack operations.
Occupancy Sensors:
•Time delay is factory
•Time delay can be field adjusted from 30 minutes to a minimum of 30 seconds.
•Daylight
•Daylight
•Sensors are designed for a detection area (sensitivity diameter) of 16' (487.68cm) when suspended 10' (304.80cm) AFF. Lowering the sensor produces a smaller area of detection. See chart and diagram for additional information.
1. End Cap Sensor Mounting | 2. |
| Sensor Mounting |
ECS occupancy sensors are available in two variations:
•Mounted in the end cap.
•The middle of an 8" (243.84cm) module.
The ECS system
Emergency battery packs can be used in conjunction with ECS for emergency egress lighting since all listed packs operate for a minimum of 90 minutes. EM Packs can be used as momentary lighting for emergency circuit for power transitions, and smaller packs are recommended for this purpose.
Coverage Diameter
16' 0" 14' 5" 12' 10" 11' 3"
Sensor Height AFF
7' 0"
8' 0"
9' 0"
10' 0"
Dimming ballasts can be used in conjunction with ECS. However, the control system will only perform ON or OFF operations and will not affect the level of dim- ming set by the dimming ballasts.
Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off.
Serial Row Linking (SRL) provides multiple continuous row communication. For every run that SRL is required, order the appropriate SRL end set from page 2 of this Specification Sheet. Consult Energos Application Guide for more detailed definitions and examples.
Mountings
Cable suspension distances are on 48" (121.92cm) and 96" (243.84cm) centers, and consist of a 4 1/2" (11.43cm) diameter canopy finished white enamel. A 1/16" (0.16cm) diameter stainless steel aircraft cable accomplishes suspension and is adjustable from 12" (30.48cm) to 36" (91.44cm). Power feeds are 18 gauge silver braided cord with clear jacket.
Energos Occupancy Sensor
Coverage Zone Chart
Height of Sensor | Broadcast Diameter | Task Diameter | ||
10' 0" (304.80cm) |
| 16' 0" (487.68cm) | 8' 0" (243.84cm) | |
9' 0" (274.32cm) |
| 14' 5" (427.99cm) | 7' 3" (214.12cm) | |
8' 0" (243.84cm) |
| 12' 10" (391.16cm) | 6' 5" (184.15cm) | |
7' 0" (213.36cm) |
| 11' 3" (336.04cm) | 5' 7" (154.18cm) | |
|
|
|
| |
Job Information |
| Type: |
|
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508)