Lightolier C4T4VN specifications Candlepower Distribution, Angle, Wall RCR

Page 2

Calculite® HID Downlight C4T4VN

Page 2 of 2

4 1/2” Aperture, 2pc Vertical, T4.5 Narrow Beam

20W T4 GE CMH LAMP, LUMEN RATING = 1700 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM

CANDLEPOWER DISTRIBUTION

625

1,250

1,875

2,500

 

ANGLE

MEAN CP LUMENS

 

0

2340

 

 

5

2039

189

 

10

1505

 

 

15

1047

306

 

20

720

 

60°

25

490

237

30

351

 

 

 

 

35

270

173

 

40

209

 

 

45

96

79

 

50

6

 

 

55

0

1

 

60

0

 

 

65

0

0

 

70

0

 

 

75

0

0

 

80

0

 

 

85

0

0

30°

90

0

 

 

 

 

LUMINANCE SUMMARY CD. / SQ. M.

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

13228

 

CEILING

 

 

80%

 

70%

 

50%

 

30%

 

 

 

 

 

 

 

 

 

 

 

55

 

32

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

65

 

8

 

 

 

75

 

0

 

 

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

85

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

.69

.69

.69

.69

.67

.67

.64

.64

.62

.62

.58

 

 

 

 

 

 

 

 

 

 

 

 

1

.67

.65

.64

.63

.64

.62

.62

.60

.60

.58

.56

 

 

 

 

 

 

 

2

.64

.62

.60

.59

.61

.58

.59

.57

.58

.55

.54

 

ZONAL LUMENS AND PERCENTAGES

 

3

.62

.59

.57

.55

.58

.55

.57

.54

.55

.53

.51

 

 

4

.60

.56

.54

.52

.56

.52

.54

.51

.53

.50

.49

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

 

 

5

.57

.54

.51

.49

.53

.49

.52

.48

.51

.48

.47

 

0-30

732

43.09

74.35

 

 

0-40

905

53.24

91.87

 

6

.55

.51

.49

.47

.51

.47

.50

.46

.49

.46

.45

 

0-60

985

57.95

100.0

 

7

.53

.49

.46

.44

.49

.44

.48

.44

.47

.44

.43

 

0-90

985

57.95

100.0

 

8

.51

.47

.44

.42

.46

.42

.46

.42

.45

.42

.41

 

40-90

80

4.71

8.13

 

9

.49

.45

.42

.40

.44

.40

.44

.40

.43

.40

.39

 

60-90

0

0.0

0.0

 

10

.47

.43

.40

.38

.42

.38

.42

.38

.42

.38

.37

 

90-180

0

0.0

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-180

985

57.95

100.00

 

LUMINAIRE INPUT WATTS = 23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 58.0% ** SC = 0.4

CERTIFIED TEST REPORT NO. 2401FR, DATE: DEC 22, 2003 COMPUTED BY LSI PROGRAM **TEST-LITE**

39W T4 PHILIPS CMH LAMP, LUMEN RATING = 3300 LMS, AROMAT BALLAST, CL FINISH TRIM

CANDLEPOWER DISTRIBUTION

875

1,750

2,625

3,500

 

ANGLE

MEAN CP LUMENS

 

0

3301

 

 

5

2998

281

 

10

2493

 

 

15

1946

556

 

20

1462

 

60°

25

1061

506

30

788

 

 

 

 

35

609

383

 

40

435

 

 

45

185

158

 

50

10

 

 

55

0

2

 

60

0

 

 

65

0

0

 

70

0

 

 

75

0

0

 

80

0

 

 

85

0

0

30°

90

0

 

 

 

 

LUMINANCE SUMMARY CD. / SQ. M.

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

25548

 

CEILING

 

 

 

80%

 

70%

 

50%

 

30%

 

 

 

 

 

 

 

 

 

 

 

55

 

0

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

65

 

0

 

 

 

75

 

0

 

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

85

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

.68

.68

.68

.68

.67

.67

.64

.64

.61

.61

.57

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

.66

.64

.63

.62

.63

.61

.61

.59

.59

.58

.55

 

 

 

 

 

 

2

 

.63

.61

.59

.57

.60

.57

.58

.56

.57

.55

.53

 

ZONAL LUMENS AND PERCENTAGES

3

 

.61

.58

.56

.54

.57

.53

.56

.52

.54

.52

.50

 

4

 

.58

.55

.52

.51

.54

.50

.53

.50

.52

.49

.48

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

 

5

 

.56

.52

.49

.47

.52

.47

.51

.47

.50

.46

.45

 

0-30

1343

40.71

71.2

 

 

0-40

1726

52.33

91.52

6

 

.54

.50

.47

.45

.49

.45

.49

.44

.48

.44

.43

 

0-60

1886

57.17

100

7

 

.52

.47

.44

.42

.47

.42

.46

.42

.45

.42

.41

 

0-90

1886

57.17

100

8

 

.50

.45

.42

.40

.44

.40

.44

.40

.43

.40

.39

 

40-90

159

4.85

8.48

9

 

.47

.43

.40

.38

.42

.38

.42

.37

.41

.37

.37

 

60-90

0

0

0

10

 

.45

.40

.38

.36

.40

.36

.40

.36

.39

.35

.35

 

90-180

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-180

1886

57.17

100

LUMINAIRE INPUT WATTS = 44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 57.2% ** SC = 0.6

CERTIFIED TEST REPORT NO. 2400FR, DATE: DEC 22, 2003 COMPUTED BY LSI PROGRAM **TEST-LITE**

70W T4 PHILIPS CMH LAMP, LUMEN RATING = 6400 LMS, AROMAT ELECTRONIC BALLAST, CL FINISH TRIM

CANDLEPOWER DISTRIBUTION

1,375

2,750

4,125

5,500

** EFFICIENCY = 57.0% ** SC = 0.6

 

ANGLE

MEAN CP LUMENS

LUMINANCE SUMMARY CD. / SQ. M.

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

0

5645

498

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

5

5314

45

 

53412

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

4588

 

55

 

0

 

CEILING

 

 

80%

 

 

70%

 

50%

 

30%

 

 

 

15

3673

1044

65

 

0

 

 

 

 

 

 

 

 

 

 

20

2797

 

75

 

0

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

 

25

2083

989

 

 

 

 

60°

85

 

0

 

 

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

30

1582

 

 

 

 

 

 

 

 

 

35

1220

770

 

 

 

 

 

0

.68

.68

.68

.68

.66

.66

.63

.63

.61

.61

.57

 

 

40

878

 

 

 

 

 

 

1

.65

.64

.63

.62

.63

.61

.60

.59

.58

.57

.54

 

 

45

386

322

 

 

 

 

 

 

2

.63

.60

.59

.57

.59

.56

.58

.55

.56

.54

.52

 

 

 

 

 

 

 

 

 

 

50

14

3

ZONAL LUMENS AND PERCENTAGES

 

3

.60

.57

.55

.53

.56

.53

.55

.52

.54

.51

.49

 

 

55

0

ZONE LUMENS

% LAMP %LUMINAIRE

 

4

.58

.54

.52

.50

.54

.49

.53

.49

.51

.48

.47

 

 

60

0

 

0-30

2530

39.54

69.8

 

5

.55

.51

.49

.47

.51

.46

.50

.46

.49

.46

.44

 

 

65

0

0

0-40

3299

51.56

91.02

 

6

.53

.49

.46

.44

.49

.44

.48

.44

.47

.43

.42

 

 

70

0

 

0-60

3625

56.65

100

 

7

.51

.46

.43

.42

.46

.41

.45

.41

.45

.41

.40

 

 

75

0

0

0-90

3625

56.65

100

 

8

.49

.44

.41

.39

.43

.39

.43

.39

.43

.39

.38

 

 

80

0

 

40-90

325

5.09

8.98

 

9

.46

.42

.39

.37

.41

.37

.41

.36

.40

.36

.36

 

 

0

60-90

0

0

0

 

 

 

85

0

90-180

0

0

0

 

10

.44

.39

.37

.35

.39

.35

.39

.34

.38

.34

.34

 

30°

90

0

 

0-180

3625

56.65

100

 

LUMINAIRE INPUT WATTS = 78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TEST REPORT NO. 2397FR, DATE: DEC 18, 2003

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPUTED BY LSI PROGRAM **TEST-LITE**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Image 2
Contents Frame-In Kit Lamp FeaturesOptions and Accessories ElectricalWall RCR Candlepower DistributionAngle

C4T4VN specifications

The Lightolier C4T4VN is an innovative lighting solution designed for versatility and energy efficiency in modern environments. This advanced lighting fixture is a part of Lightolier's commitment to providing high-quality, sustainable lighting products that meet the evolving needs of residential, commercial, and industrial spaces.

One of the standout features of the C4T4VN is its integrated LED technology, which offers several advantages over traditional lighting options. LEDs consume significantly less energy and have a longer lifespan, which not only reduces energy costs but also lowers the frequency of replacements, making it a cost-effective solution over time. The C4T4VN harnesses this technology to deliver bright, high-quality illumination while maintaining impressive energy-efficiency ratings.

The fixture is designed with a sleek and modern aesthetic, allowing it to seamlessly integrate into a variety of décor styles. Available in multiple finishes, the C4T4VN can be customized to match the specific design requirements of any space, whether it’s a contemporary office, a cozy home, or a vibrant retail setting.

Another key characteristic of the C4T4VN is its advanced dimming capabilities. The fixture is compatible with various dimming systems, enabling users to adjust the light levels according to their preferences and the task at hand. This adaptability not only enhances user comfort but also contributes to energy savings by allowing for reduced lighting levels in less occupied areas.

Additionally, the C4T4VN features a robust thermal management system, which ensures optimal performance and longevity of the LEDs. This system mitigates heat buildup, maintaining consistent light output and minimizing the risk of premature failure.

The C4T4VN is also equipped with cutting-edge smart technology options, providing integration with building management systems and smart home devices. This allows for advanced control systems, including scheduling, occupancy sensing, and remote management, further enhancing energy efficiency and user convenience.

In summary, the Lightolier C4T4VN combines high-performance LED technology with a modern design, advanced features, and smart capabilities, making it an ideal solution for those seeking both versatility and efficiency in their lighting solutions. With its emphasis on sustainability and innovation, the C4T4VN stands out in the marketplace as a reliable choice for a wide range of applications.