Samsung MO15PSDSV/XSG What does labelling involve?continue, Environmental Requirements, Lead

Page 64

User’s Manual

Information

Regulatory

What does labelling involve?(continue)

TCO Development Unit 1996-11-29

On the page this folder you will find a brief summary of the environmental requirements met by this product. The complere environmental criteria document may be ordered from:

TCO Development Unit S-11494 Stockholm Sweden

Fax: +46 8 782 92 07

E-mail (Internet): development@tco.se

Current information regarding TCO'95-approved and labelled products may also be obtained via the Internet, using the address:

http://www.tco-info.com/

TCO'95 is a co-operative project between(3 logos)

Environmental Requirements

Brominated flame retardants are present in printed circuit boards, cables, wires, casings and housings. In turn, they delay the spread of fire. Up to thirty percent of the plastic in a computer casing can consist of flame retardant substances. These are related to another group of environmental toxins, PCBs, which are suspected to give rise to similar harm, including reproductive damage in fish eating birds and mammals, due to the bioaccumulative processes. Flame retardants have been found in human blood and researchers fear that disturbances in foetus development may occur. TCO'95 demand requires that plastic components weighing more than 25 grams must not contain organically bound chlorine and bromine.

Lead

Lead can be found in picture tubes, display screens, solders and capacitors. Lead damages the nervous system and in higher doses, causes lead poisoning. TCO'95 requirement Permits the inclusion of lead since no replacement has yet been developed.

Cadmium

Cadmium is present in rechargeable batteries and in the colour generating layers of certain computer displays. Cadmium damages the nervous system and is toxic in high doses. TCO'95 requirement states that batteries may not contain more than 25 ppm (parts per million) of cadmium. The colour-generating layers of display screens must not contain any cadmium.

Mercury

Mercury is sometimes found in batteries, relays and switches. Mercury damages the nervous system and is toxic in high doses. TCO'95 requirement states that batteries may not contain more than 25 ppm (parts per million) of mercury. It also demands that no mercury is present in any of the electrical or electronics components concerned with the display unit.

CFCs (freons)

CFCs (freons) are sometimes used for washing printed circuit boards and in the manufacturing of expanded foam for packaging. CFCs break down ozone and thereby damage the ozone layer in the stratosphere, causing increased reception on Earth of ultraviolet light with consequent increased risks of skin cancer (malignant melanoma).

. The relevant TCO'95 requirement: Neither CFCs nor HCFCs may be used during the manufacturing of the product or its packaging.

Image 64
Contents SyncMaster 152B/152T Index Notational Notation ConventionsPower This may cause a fire Installation Do not place the monitor face down Clean Other Never insert anything metallic into the monitor openings Unpacking IntroductionSyncMaster 152T Power button Use this button to turn the monitor on and off FrontUser’s Manual Rear User’s Manual Connecting Your Monitor Setup-GeneralSetup SyncMaster 152T Setup SyncMaster 152T/152B Attaching a base Option Setup Setup Microsoft Windows XP Operating System Setup How to install Click Start , Setting , Control Panel Microsoft Windows NT Operating System On-Screen Display Brightness ContrastFine CoarsePosition Geometry Reset Color ResetColor Temperature Color ControlLanguage Menu Position Display Mode Menu Display TimeAuto Adjustment OSD Lock/UnlockSyncMaster 152T Image Lock Position Reset Halftone Follow these steps to change the language used in the menu Menu Position Menu Display Time Auto Adjustment Symptom Check List Solutions Check ListCheck List Symptom Solutions Screen showsTroubleshooting Question Answer How can I change the frequency?Self-Test Feature Check Self-Test Feature Check Werning Messages EnvironmentUseful Tips Judging the monitors working conditionSpecifications Environmental considerations General General SyncMaster 152T PowerSaver SyncMaster 152T State Normal Operation Power saving modePreset Timing Modes SyncMaster 152B/152T SeService InformationService Terms Regulatory FCC Information User InstructionsIC Compliance Notice MPR II ComplianceEuropean Notice Europe only PCT NoticeWhy do we have environmentally-labelled monitors? What does labelling involve?What does labelling involve?continue Environmental RequirementsLead CadmiumWhy do we have environmentally labelled computers? TCO Development Environmental requirements Flame retardantsHow to install the Natural Color software How to delete the Natural Color software programNatural Color Natural Color Software ProgramFor Better Display Authority