Lightolier 8672 instruction sheet Instructions for Lamping, Used in Place of Glass Guard

Page 2

INSTRUCTIONS FOR LAMPING

1.Check to see that power is OFF before Iamping or relamping.

2.Remove APERTURE BAFFLE from HOUSING by pulling straight out as shown in Fig. 2.

3.Assemble LAMP to APERTURE BAFFLE as shown in Fig. 3 making certain GLASS LAMP GUARD is sandwiched between LAMP and APERTURE BAFFLE, and firmly held in placce by LAMP SPRINGS. CAUTION: Do not touch lamp capsule with bare fingers.

4.Connect SOCKET to LAMP by inserting pins on LAMP into holes in SOCKET (Fig. 3).

Replace APERTURE BAFFLE back into HOUSING

by pushing straight in.

1S:8672

0989

Page 2 of 2

I

n

H

HOUSING

APERTURE BAFFLE

WARNING: LAMP MANUFACTURERS REQUIRE THE GLASS LAMP GUARD BE IN PLACE BEFORE ENERGIZING LAM~ AND THAT GREAT CARE SHOULD BE TAKEN THAT LAMP IS FULLYCOOLED BEFORE RELAMPING. COLOR FILTERCAN BE

USED IN PLACE OF GLASS GUARD.

1

NOTE: LOW VOLTAGE FIXTURES should be

dimmed only with special dimmers intended

specifically for that purpose. Use Lightolier

Lytemode, Scenist, Crescendo VA, Neptune VA,

Precision VAI, Easyset VA, Sunrise VA, Radiant

VA or equivalent products by others or variable

auto-transformers or electronic dimmers

intended for use with low voltage fixtures.

NOTE: Lamp wattage 50W max.

FIG. 2

SOCKET

d

GLASS LAMP

Ell

ADi_I

T

IT

CLAMP

““”,

,”

 

 

 

LAMP SPRING

- ,APFRTIJRE. !-,,,”

1=BAFFLE

FIG. 3

Image 2
Contents Retain these instructions for maintenance reference Instructions for Connecting Lytejacks FixturesTo 8600 System Power Jacks IS8672Instructions for Lamping Used in Place of Glass Guard