Lightolier specifications A7053CL A19 75 Watt, A7053BK A19 75 Watt, Spacing Ratio =

Page 2

Calculite® Incandescent Open Downlight A7053

Page 2 of 2

A7053CL A19 75 Watt

40

 

 

 

 

 

 

 

75 Watt A19

 

 

 

 

 

 

FOOTCANDLES

 

 

 

 

 

 

1190 Lumens Per Lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

RCR = 5 (Rm. Width - 2Mtg. Ht. above work plane)

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

RCR = 10 (Rm. Width - Mtg. Ht. above work plane)

 

 

 

 

 

 

 

Room Surface Reflectances:

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

80% Ceiling; 50% Walls; 20% Floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INITIAL 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

40

60

80

100

120

140

 

 

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

4

5

6

7

8

9

10

11

12

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

Use quick calculator chart to determine spacing of luminaires for desired level of illumination.

Conversion Factors:

40W A-19 (Clear): F.C. X 0.40; (Gold): F.C. x 0.35

60W A-19 (Clear): F.C. X 0.75; (Gold): F.C. x 0.65

75W A-19 (Gold): F.C. X 0.90;

100W A-19 (Clear): F.C. x 1.5; (Gold): F.C. x1.3

4 1/2” Aperture A19

A7053BK A19 75 Watt

40

 

 

 

 

 

 

 

 

75 Watt A19

 

 

 

 

 

 

 

 

 

 

FOOTCANDLES

 

 

 

 

 

 

 

1190 Lumens Per Lamp

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

RCR = 5 (Rm. Width - 2Mtg. Ht. above work plane)

 

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

 

RCR = 10 (Rm. Width - Mtg. Ht. above work plane)

 

 

 

 

 

 

 

 

Room Surface Reflectances:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

80% Ceiling; 50% Walls; 20% Floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INITIAL 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

90

100

110

 

 

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

3

4

 

5

 

6

 

7

 

 

8

 

9

 

 

10

 

 

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

Use quick calculator chart to determine spacing of luminaires for desired level of illumination.

Conversion Factors:

40W A-19 (Black Alzak): F.C. X 0.40; (Multi-groove): F.C. x 0.35￿

60W A-19 (Black Alzak): F.C. X 0.75; (Multi-groove): F.C. x 0.65￿

75W A-19 (Multi Groove): F.C. X 0.90; ￿

100W A-19 (Black Alzak): F.C. x 1.5; (Multi-groove): F.C. x1.3

Spacing Ratio = 1.2

Spacing Ratio = 1.1

90°

125

60°

250

375

30°

500

ITL, Inc. Report No. 23108

Date: 4-4-78

Efficiency: 58.2%

ITL, Inc. report No. 23108C. Date: 4-4-78

CANDLEPOWER SUMMARY

 

 

ZONAL

DEG

CP

FLUX

0

438

 

5

440

42

15

420

119

25

511

237

35

274

172

45

155

120

55

2

2

65

0

0

75

0

0

85

0

0

90

0

 

 

ZONAL SUMMARY

 

ZONE

LUMENS

LAMP

FIXT

0-30

397

33.4

57.4

0-40

570

47.9

82.2

0-60

691

58.1

99.8

0-90

693

58.2

100.0

90-180

0

0

.0

0-180

693

58.2

100.0

90°

CANDLEPOWER SUMMARY

 

 

 

ZONAL

 

 

 

 

 

 

 

 

DEG

CP

FLUX

 

100

 

0

427

 

 

 

5

422

40

 

60°

 

 

 

15

369

105

 

 

 

 

 

 

25

368

170

 

200

 

35

200

126

 

 

 

45

89

69

 

 

 

55

0

0

 

300

 

65

0

0

 

 

 

75

0

0

 

30°

 

85

0

0

 

 

90

0

 

 

400

 

 

 

 

ZONAL SUMMARY

 

 

 

 

 

ZONE

LUMENS

LAMP

FIXT

 

0-30

 

315

26.5

61.7

 

0-40

 

441

37.0

86.3

ITL, Inc. Report No. 23151

0-60

 

510

42.8

99.8

Date: 4-10-78

0-90

 

511

42.9

100.0

Efficiency: 42.9%

90-180

 

0

0.0

0.0

 

 

ITL, Inc. report No. 23151C. Date: 4-10-78

0-180

 

511

42.9

100.0

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

80

 

 

 

70

 

 

50

 

 

30

 

 

 

10

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

30

10

 

 

 

% WALL REFLECTANCE

 

 

 

50

30

10

0

 

 

 

 

50

30

10

50

30

10

50

30

10

 

 

1

 

.65

.63

.62

.63

.62

.61

.61

.60

.59

.59

.58

.57

 

.57

.56

.56

.55

RATIO

2

 

.61

.58

.56

.60

.58

.56

.58

.56

.55

.56

.55

.53

 

.54

.53

.52

.51

3

 

.57

.54

.52

.56

.53

.51

.54

.52

.50

.53

.51

.50

 

.52

.50

.49

.48

4

 

.53

.50

.48

.52

.50

.47

.51

.49

.47

.50

.48

.46

 

.49

.47

.46

.45

CAVITY

 

 

5

 

.50

.46

.44

.49

.46

.44

.48

.45

.43

.47

.45

.43

 

.46

.44

.42

.42

6

 

.46

.43

.41

.46

.43

.40

.45

.42

.40

.44

.42

.40

 

.43

.41

.40

.39

ROOM

7

 

.43

.40

.37

.43

.39

.37

.42

.39

.37

.41

.39

.37

 

.41

.38

.36

.36

8

 

.40

.37

.34

.40

.36

.34

.39

.36

.34

.39

.36

.34

 

.38

.35

.34

.33

9

 

.37

.33

.31

.37

.33

.31

.36

.33

.31

.36

.33

.31

 

.35

.33

.31

.30

 

 

 

 

10

 

.34

.31

.28

.34

.31

.28

.34

.31

.28

.33

.30

.28

 

.33

.30

.28

.27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion Factor: For 40W, 60W and 100W A19 units with clear reflector, multiply C.U.’s by 1.0. For 40W, 60W, 75W and 100W A19 units with gold reflector, multiply C.U.’s by 0.9.

COEFFICIENTS OF UTILIZATION

%EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

80

 

 

 

70

 

 

50

 

 

30

 

 

 

10

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

30

10

 

 

 

% WALL REFLECTANCE

 

 

 

50

30

10

0

 

 

 

 

50

30

10

50

30

10

50

30

10

 

 

1

 

.48

.47

.46

.47

.46

.45

.45

.44

.44

.44

.43

.42

 

.42

.42

.41

.40

RATIO

2

 

.45

.43

.42

.44

.43

.42

.43

.42

.41

.42

.41

.40

 

.40

.40

.39

.38

3

 

.42

.40

.39

.42

.40

.38

.40

.39

.38

.39

.38

.37

 

.39

.37

.37

.36

CAVITY

4

 

.40

.38

.36

.39

.37

.36

.38

.37

.35

.37

.36

.35

 

.37

.35

.34

.34

6

 

.35

.33

.31

.35

.32

.31

.34

.32

.31

.34

.32

.30

 

.33

.31

.30

.30

ROOM

5

 

.37

.35

.33

.37

.35

.33

.36

.34

.33

.35

.34

.32

 

.35

.33

.32

.32

7

 

.33

.30

.29

.33

.30

.29

.32

.30

.28

.32

.30

.28

 

.31

.29

.28

.28

 

 

 

 

8

 

.31

.28

.27

.30

.28

.26

.30

.28

.26

.30

.28

.26

 

.29

.27

.26

.26

 

9

 

.29

.26

.24

.28

.26

.24

.28

.26

.24

.28

.26

.24

 

.27

.25

.24

.24

 

10

 

.27

.24

.23

.27

.24

.23

.26

.24

.23

.26

.24

.22

 

.26

.24

.22

.22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion Factor: For 40W, 60W and 100W A19 units with black Alzak, multiply C.U.’s by 1.0. For 40W, 60W, 75W and 100W A19 units with Multi-Groove, multiply C.U.’s by 0.9.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) • B0204

Image 2
Contents Reflector Trim Frame-In Kit Lamp FeaturesAccessories and Options Remodeler Frame-In Kit LampSpacing Ratio = A7053CL A19 75 WattA7053BK A19 75 Watt