Architectural Decorative 4A28
Page 2 of 2
Features
1.Diffusing Reflector: White translucent acrylic, 3/16” thick.
2.Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3.Chassis: Steel, 20 gauge,
4.Suspension: Swivel (central) stem, 3/4” steel tube. Canopy, 7” Dia., fas- tened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.
5.Lampholder:
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts. |
|
|
| ||||||
| General Electric |
|
| Osram/Sylvania |
|
| Philips | ||
26W Triple Tube | (Amalgam) Compact | Fluorescent Lamp | |||||||
| F26TBX/*/A/4P |
|
| CF26DT/E/IN/* |
|
| |||
|
|
| |||||||
32W Triple Tube | (Amalgam) Compact | Fluorescent Lamp | |||||||
| F32TBX/*/A/4P |
|
| CF32DT/E/IN/* |
|
| |||
|
|
|
|
| |||||
42W Triple Tube | (Amalgam) Compact | Fluorescent Lamp | |||||||
| F42QBK/*/A/4P |
|
| CF42DT/E/IN/* |
|
| |||
*Manufacturers’ color temperature designation. |
|
|
|
|
Electrical
Ballast: Electronic,
4 Lamps |
| 26 Watt |
| 32Watt |
| 42Watt |
| ||
|
|
|
| ||||||
Voltage |
| 120V | 277V |
| 120V | 277V | 120V |
| 277V |
Total Input Watts |
| 110 | 110 |
| 140 | 140 | 186 |
| 186 |
Max. Line Current (amps) |
| 1.11 | 0.48 |
| 1.40 | 0.60 | 0.60 |
| 0.80 |
Power Factor |
| >0.98 | >0.98 |
| >0.98 | >0.98 | >0.99 |
| >0.99 |
Ballast Factor |
| 1.02 | 1.02 |
| 0.96 | 0.96 | 0.95 |
| 0.95 |
THD<10% Minimum Starting Temperature:
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus listed suitable for damp locations.
Application Data
28 Inch Diameter |
|
|
|
| |
30’ x 30’ x 10’ Space |
|
|
| ||
Luminaire |
| Spacing: 10’ x 10’ |
| ||
|
|
| Susp. Dist. 28” |
| |
4 Lamps |
| 26W |
| 32W | 42W |
|
| TTT |
| TTT | TTT |
Illum. (FC) |
| 30 |
| 41 | 54 |
Maint. |
|
|
|
|
|
Lum. |
| 8/1 |
| 8/1 | 9/1 |
Ratio |
|
|
|
|
|
Watts/ |
| 1.10 |
| 1.36 | 1.86 |
Sq. Ft. |
|
|
|
|
|
|
|
|
|
|
|
Reflectances: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.
Pendalux Cirrus 28” Diameter Body 4-26/32/42 Triple Tube
CERTIFIED TEST REPORT NO. 4A28442
COMPUTED BY LSI PROGRAM
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4A28442APBU, HOUSING COVER WITHOUT FLANGE, 28” DIFFUSER
|
|
|
| CANDLEPOWER SUMMARY |
| ||||
|
|
| ANGLE MEAN CP LUMENS | ANGLE MEAN CP LUMENS | |||||
|
|
| 0 | 395 |
|
| 90 | 53 |
|
|
|
| 5 | 394 | 38 |
| 95 | 121 | 199 |
|
|
| 10 | 389 |
|
| 100 | 433 |
|
|
|
| 15 | 382 | 108 |
| 105 | 834 | 871 |
|
|
| 20 | 372 |
|
| 110 | 1193 |
|
|
|
| 25 | 360 | 166 |
| 115 | 1470 | 1453 |
|
|
| 30 | 342 |
|
| 120 | 1722 |
|
|
|
| 35 | 321 | 201 |
| 125 | 1912 | 1704 |
|
|
| 40 | 297 |
|
| 130 | 2053 |
|
|
|
| 45 | 272 | 211 |
| 135 | 2149 | 1656 |
|
|
| 50 | 247 |
|
| 140 | 2203 |
|
|
|
| 55 | 221 | 198 |
| 145 | 2215 | 1386 |
|
|
| 60 | 193 |
|
| 150 | 2192 |
|
|
|
| 65 | 165 | 165 |
| 155 | 2178 | 1005 |
|
|
| 70 | 141 |
|
| 160 | 2136 |
|
|
|
| 75 | 116 | 123 |
| 165 | 1949 | 546 |
|
|
| 80 | 92 |
|
| 170 | 1666 |
|
|
|
| 85 | 71 | 78 |
| 175 | 1624 | 159 |
|
|
| 90 | 53 |
|
| 180 | 1756 |
|
|
|
|
| ZONAL LUMENS AND PERCENTAGES |
| ||||
|
|
| ZONE | LUMENS | % LAMP | %LUMINAIRE | |||
| DATE: OCT. 4, 2000 |
| |||||||
| PREPARED FOR: | 311 |
| 2.43 | 3.03 |
| |||
| LIGHTOLIER, FALL RIVER, MA | 512 |
| 4.01 | 5.00 |
| |||
|
| 920 |
| 7.20 | 8.97 |
| |||
|
| 1287 | 10.06 | 12.54 |
| ||||
|
| 774 |
| 6.05 | 7.55 |
| |||
|
| 366 |
| 2.86 | 3.57 |
| |||
|
| 8978 | 70.15 | 87.46 |
| ||||
|
| 10266 | 80.21 | 100.00 |
|
** EFFICIENCY = 80.2% **
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
|
| 80 |
|
| 70 |
|
| 50 |
|
| 30 |
|
| 10 |
|
|
| |
|
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 | |
| 1 | .68 .65 .63 | .60 .57 .54 | .44 .42 .41 | .29 .28 .27 | .15 .15 .14 | .08 | |||||||||||
RATIO | 2 | .59 .55 .51 | .52 .48 .45 | .38 .35 .33 | .25 .24 .22 | .13 .13 .12 | .07 | |||||||||||
3 | .52 .47 .42 | .46 .41 .37 | .33 .30 .28 | .22 .21 .19 | .12 .11 .10 | .06 | ||||||||||||
| ||||||||||||||||||
CAVITY | 4 | .46 .40 .36 | .40 .35 .32 | .30 .26 .24 | .20 .18 .16 | .10 .10 .09 | .05 | |||||||||||
6 | .36 .30 .26 | .32 .27 .23 | .24 .20 .17 | .16 .14 .12 | .08 .07 .07 | .04 | ||||||||||||
ROOM | 5 | .40 .35 .30 | .36 .31 .27 | .26 .23 .20 | .18 .15 .14 | .09 .08 .08 | .04 | |||||||||||
7 | .32 .26 .22 | .28 .23 .20 | .21 .18 .15 | .14 .12 .10 | .08 .06 .06 | .03 | ||||||||||||
| ||||||||||||||||||
| 8 | .38 .29 .19 | .26 .21 .17 | .19 .16 .13 | .13 .11 .09 | .07 .06 .05 | .03 | |||||||||||
| 9 | .36 .26 .17 | .23 .18 .15 | .17 .14 .11 | .12 .09 | .08 | .06 .05 .04 | .02 | ||||||||||
| 10 | .33 .24 .15 | .21 .16 .13 | .16 .12 .10 | .11 .08 | .07 | .06 .05 .04 | .02 |
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Job Information | Type: |
|
|
Lightolier a Genlyte company |
| www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 Genlyte Group LLC • B0605