Lightolier 412U manual 625

Page 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specification Decorative Performance Pendalyte  412U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 5 of 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12" Compact Fluorescent

Satin Aluminum Reflector  Catalog No. 41270U / 42SR, 70W CFL, 5200 Lumens.

625

 

 

60°

1250

 

1875

 

2500

30°

 

Report No. 2606FR

SC = .8

CANDLEPOWERSUMMARY

ZONAL LUMENS AND PERCENTAGES

ANGLE

MEANCP

LMS

ZONE

LUMENS

% LAMP

%LUMINAIRE

0

2545

 

0-30

1473

28.33

41.65

5

2483

232

0-40

2240

43.09

63.36

10

2218

 

0-60

3366

64.74

95.19

15

1906

544

0-90

3536

68.01

100.00

20

1654

 

40-90

1295

24.92

36.64

25

1494

696

60-90

170

3.27

4.81

30

1375

 

90-180

0

.00

.00

35

1229

768

0-180

3536

68.01

100.00

40

1056

 

 

** EFFICIENCY = 68.0% **

45

880

679

 

50

694

 

 

 

 

 

55

497

446

 

 

 

 

60

301

 

 

 

 

 

65

131

151

 

 

 

 

70

44

 

 

 

 

 

75

14

19

 

 

 

 

80

0

 

 

 

 

 

85

0

0

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

Ceiling

 

 

80%

 

70%

 

50%

 

 

30%

 

 

 

 

 

 

 

 

 

 

Wall

70

50

30

10

50

10

 

50

10

 

 

50

10

0

 

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

 

 

0

.81

.81

.81

.81

.79

.79

 

.76

.76

 

 

.72

.72

.68

 

 

1

.76

.74

.72

.71

.73

.69

 

.70

.67

 

 

.67

.65

.62

 

 

2

.72

.68

.65

.62

.67

.62

 

.65

.60

 

 

.63

.59

.57

 

 

3

.67

.62

.58

.55

.61

.55

 

.60

.54

 

 

.58

.53

.51

 

 

4

.63

.57

.53

.49

.56

.49

 

.55

.49

 

 

.53

.48

.46

 

Ratio

5

.59

.52

.48

.44

.52

.44

 

.50

.44

 

 

.49

.43

.42

 

6

.55

.48

.43

.40

.47

.40

 

.46

.39

 

 

.45

.39

.38

 

Cavity

7

.51

.44

.39

.36

.43

.35

 

.42

.35

 

 

.41

.35

.33

 

8

.48

.40

.35

.32

.40

.32

 

.39

.32

 

 

.38

.31

.30

 

Room

9

.45

.37

.32

.29

.37

.29

 

.36

.29

 

 

.35

.28

.27

 

 

10

.42

.34

.29

.26

.34

.26

 

.33

.26

 

 

.32

.26

.25

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 79.0

White Glass Reflector  Catalog No. 41270U / 42WH, 70W CFL, 5200 Lumens.

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

500

60°

 

1000

 

1500

30°

 

Report No. 2644FR

SC = 1.0

ANGLE MEAN CP LMS

01401

51384 130

10

1283

 

15

1172

334

20

1084

 

25

1013

465

30

913

 

35

781

491

40

649

 

45

541

421

50

443

 

55

365

334

60

318

 

65

284

284

70

260

 

75

244

259

80

232

 

85219 243

90220

ANGLE

MEAN CP

LMS

ZONE

LUMENS

% LAMP

%LUMINAIRE

90

220

 

0-30

929

17.88

20.67

95

231

252

0-40

1420

27.31

31.58

100

242

 

0-60

2175

41.84

48.37

105

252

266

0-90

2961

56.95

65.84

110

259

 

40-90

1541

29.64

34.26

115

265

262

60-90

785

15.11

17.47

120

267

 

90-180

1536

29.55

34.16

125

268

240

0-180

4497

86.49

100.00

130

266

 

 

 

 

 

135

262

203

 

** EFFICIENCY=86.5% **

140

256

 

 

 

 

 

145247 155

150237

155221 102

160200

165

173

48

170

133

 

175

86

9

180

67

 

Ceiling

 

 

80%

 

70%

 

50%

 

30%

 

 

 

 

 

 

 

 

 

 

Wall

70

50

30

10

50

10

 

50

10

 

50

10

0

 

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

 

 

0

.96

.96

.96

.96

.90

.90

 

.80

.80

 

.70

.70

.57

 

 

1

.87

.83

.79

.75

.78

.71

 

.69

.64

 

.60

.57

.46

 

 

2

.79

.73

.67

.62

.68

.59

 

.61

.53

 

.53

.48

.39

 

 

3

.73

.64

.58

.53

.61

.50

 

.54

.46

 

.48

.41

.34

 

 

4

.67

.58

.51

.46

.55

.44

 

.49

.40

 

.43

.36

.30

 

Ratio

5

.62

.52

.45

.40

.49

.38

 

.44

.35

 

.39

.32

.27

 

6

.58

.47

.40

.35

.45

.34

 

.40

.31

 

.36

.28

.24

 

Cavity

7

.53

.42

.36

.31

.40

.30

 

.36

.27

 

.33

.25

.21

 

8

.50

.39

.32

.27

.37

.26

 

.33

.25

 

.30

.23

.19

 

Room

9

.46

.36

.29

.24

.34

.24

 

.31

.22

 

.28

.20

.17

 

 

10

.43

.33

.26

.22

.31

.21

 

.28

.20

 

.26

.18

.15

 

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 72.0

Amber Glass Reflector  Catalog No. 41270U / 42AB, 70W CFL, 5200 Lumens.

CANDLEPOWER SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

375

60°

750

1025

30°

1500

Report No. 2643FR

SC = 1.0

ANGLE MEAN CP LMS

01444

51450 136

10

1351

 

15

1233

351

20

1139

 

25

1057

486

30

944

 

35

794

499

40

643

 

45

512

398

50

392

 

55

286

265

60

219

 

65

163

165

70

119

 

75

83

90

80

53

 

85

27

31

90

7

 

ANGLE

MEAN CP

LMS

ZONE

LUMENS

% LAMP

%LUMINAIRE

90

7

 

0-30

972

18.71

39.46

95

6

7

0-40

1471

28.30

59.70

100

7

 

0-60

2135

41.07

86.62

105

8

8

0-90

2421

46.56

98.21

110

8

 

40-90

949

18.26

38.51

115

8

8

60-90

285

5.49

11.59

120

8

 

90-180

44

.85

1.79

125

8

7

0-180

2465

47.41

100.00

130

8

 

 

 

 

 

135

8

6

 

** EFFICIENCY = 47.4% **

140

8

 

 

 

 

 

145

7

4

 

 

 

 

150

6

 

 

 

 

 

155

5

2

 

 

 

 

160

4

 

 

 

 

 

165

3

1

 

 

 

 

170

2

 

 

 

 

 

175

0

0

 

 

 

 

180

0

 

 

 

 

 

Ceiling

 

 

80%

 

70%

 

50%

 

30%

 

 

 

 

 

 

 

 

 

 

Wall

70

50

30

10

50

10

 

50

10

 

50

10

0

 

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

.56

.56

.56

.56

.55

.55

 

.52

.52

 

.50

.50

.47

 

 

1

.53

.51

.49

.48

.50

.47

 

.48

.45

 

.46

.44

.41

 

 

2

.49

.46

.44

.41

.45

.41

 

.43

.40

 

.42

.39

.37

 

 

3

.46

.42

.39

.36

.41

.36

 

.40

.35

 

.38

.35

.33

 

 

4

.43

.38

.35

.32

.38

.32

 

.36

.32

 

.35

.31

.30

 

Ratio

5

.40

.35

.31

.29

.34

.29

 

.33

.28

 

.32

.28

.27

 

6

.37

.32

.28

.26

.32

.26

 

.21

.26

 

.30

.25

.24

 

Cavity

7

.35

.29

.26

.23

.29

.23

 

.28

.23

 

.27

.23

.22

 

8

.32

.27

.23

.21

.26

.21

 

.26

.21

 

.25

.21

.20

 

Room

9

.30

.25

.21

.19

.24

.19

 

.24

.19

 

.23

.19

.18

 

10

.28

.23

.19

.17

.23

.17

 

.22

.17

 

.22

.17

.16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 72.0

Notes: Amber Glass and Cobalt Blue Glass have the same Photometrics.

Job Information

Type:

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • E0708

Lightolier is a Philips group brand

Image 5
Contents Black 120 5-wire Straight Cord Grey 120 5-wire Straight CordGrey Wire, 25’ Cord/Cable Black Wire, 25’ Cord/CableReport No FR SC = Candlepower Summary Zonal Lumens and PercentagesCandlepower Summary Candlepowersummary Zonal Lumens and Percentages 625 1250 625 852 660 679 491 441 305 138 156

412U specifications

The Lightolier 412U is a premium lighting fixture designed for both commercial and residential applications. Renowned for its versatility and superior performance, the 412U has become a popular choice among architects, lighting designers, and homeowners seeking to enhance their spaces with elegant illumination.

One of the main features of the Lightolier 412U is its energy-efficient LED technology. By utilizing LED bulbs, the 412U not only provides bright and vibrant light but also significantly reduces energy consumption compared to traditional incandescent fixtures. This energy efficiency translates to lower electricity bills and a reduced carbon footprint, making it an excellent choice for environmentally conscious consumers.

The 412U also boasts a sleek and contemporary design that seamlessly integrates into various architectural styles. Its minimalist aesthetic ensures that it complements both modern and traditional settings without overpowering the overall decor. With a range of finishes available, including matte white, black, and brushed nickel, the Lightolier 412U can be customized to fit any design scheme.

Another notable characteristic of the 412U is its adjustable lighting capabilities. The fixture features a pivoting head, which allows users to direct light exactly where it is needed. This flexibility makes the 412U suitable for a variety of applications, including accent lighting, task lighting, or general illumination. Whether used in living rooms, offices, or retail spaces, users can easily create the desired ambiance.

Furthermore, the Lightolier 412U is designed with longevity in mind. Crafted from high-quality materials, it ensures durability and long-lasting performance. The LED bulbs used in the fixture have an impressive lifespan, reducing the frequency of replacements and maintenance, which is particularly advantageous in commercial settings.

In addition to its aesthetic and functional appeal, the Lightolier 412U is compatible with smart home technologies. With the integration of smart controls, users can adjust brightness levels, color temperature, and even set schedules for when the lights turn on or off, enhancing convenience and control over lighting environments.

In conclusion, the Lightolier 412U stands out as an exceptional lighting solution that combines energy efficiency, design flexibility, and advanced technology. Its blend of aesthetics, functionality, and innovation makes it a preferred choice for those looking to elevate their lighting experience while enjoying the benefits of modern energy-efficient technologies.