Lightolier 26096 Remove Bottom Cover from Feed Track or Connector, Power EXTENSION, IN-LINE, T

Page 2

READ AND UNDERSTAND ALL TRACK, CONNECTOR, FEED-IN-KITS, AND ACCESSORY

INSTRUCTION SHEETS BEFORE INSTALLING ANY TRACK ITEM

This fixture is intended for installation in accordance with the National Electrical Code and local or Federal regulations. To assure full compliance with codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS:26096

0597

Page 2 of 3

7.Rotate GRID CEILING MOUNTING CLIPS onto the T-BAR. (Fig. 3) Use 2 GRID CEILING MOUNTING CLIPS for a 2’ or 4’ TRACK UNIT, 3 for an 8’ TRACK UNIT, and 4 for a 12’ TRACK UNIT. DO NOT EXCEED 4’ BETWEEN T-BAR MOUNTING CLIPS. Use more CLIPS for additional support in heavily loaded applications.

8.Remove BOTTOM COVER from FEED TRACK or CONNECTOR.

9.Remove the KNOCK OUT PLATE from the FEED TRACK or CONNECTOR (retain the SCREW). (Fig. 5)

10.Break the proper TAB from the PLATE ASSEMBLY:

FEED TRACK: DO NOT BREAK ANY TAB. (Fig. 5)

POWER EXTENSION, IN-LINE, “T”, AND “X”

CONNECTORS: BREAK THE 90° TAB OFF THE PLATE ASSEMBLY. (Fig. 6)

“L” CONNECTOR: BREAK THE 90° TAB AND STRAIGHT TAB FROM THE PLATE ASSEMBLY. (Fig. 7)

11.Attach the PLATE ASSEMBLY onto the FEED TRACK or CONNECTOR using the SCREW. (Fig. 5 & 6)

12.Place the CANOPY SPACER on the PLATE ASSEMBLY.

13.Align the PLATE ASSEMBLY with the OUTLET BOX passing the wires through the center hole in the PLATE ASSEMBLY.

14.Secure the TRACK to the surface by rotating the MOUNTING CLIPS into the TRACK.

15.Rotate the CROSS BAR until the SLOTS are in-line with the OUTLET BOX MOUNTING HOLES.

NOTE: THE CROSS BAR MUST COVER THE SLOT IN THE CANOPY PLATE AFTER THE CANOPY PLATE IS ASSEMBLED. PLEASE CHECK BEFORE SECURING THE PLATE ASSEMBLY TO THE OUTLET BOX.

Secure the PLATE ASSEMBLY to the OUTLET BOX using the

THIN HEAD SCREWS.

16.Attach the GROUND WIRE on the CANOPY PLATE to the OUTLET BOX. Slide the CANOPY PLATE between the CROSS BAR and FEED TRACK or CONNECTOR.

17.Wire the TRACK or CONNECTOR as shown in instruction sheets IS:26000, IS:26046, or IS:26050 which are included in the TRACK and CONNECTOR packages.

18.Snap the BOTTOM COVER into the TRACK or CONNECTOR to cover the wire terminals.

FIG. 2

90°

T-BAR

OUTLET BOX

 

BULB

VERTICAL K.O.

GROUND CLIP

RECTANGULAR K.O.

OUTLET

BOX CLIPGRID CEILING MOUNTING CLIP

 

GROUND

GROUND

 

WIRE

FIG. 3

CLIP

 

 

 

FIG. 4

SCREW

PLATE ASSEMBLY

 

KNOCK OUT

PLATE

FEED TRACK

SCREW

PLATE ASSEMBLY

FIG. 6

 

90°TAB

 

KNOCK OUT

 

PLATE

 

POWER EXTENSION CONNECTOR,IN-LINE, “T”,OR “X”

FIG. 5

90°TAB

PLATE ASSEMBLY

 

KNOCK OUT

PLATE

STRAIGHT TAB

“L” CONNECTOR

FIG. 7

®

LIGHTOLIER a GENLYTE company.

631 Airport Road, Fall River, MA 02720

Image 2
Contents Instructions Instruction Sheets Before Installing ANY Track ItemCeiling & Ceiling Grid Ceiling Panel Type Mounting Clip USE UseusePlace the Canopy Spacer on the Plate Assembly Remove Bottom Cover from Feed Track or ConnectorPower EXTENSION, IN-LINE, T, Secure the Plate Assembly to the Outlet BOX usingBAR from Outlet BOX Ground Wire approximately 8 long to the Outlet BOXRemove appropriate Vertical and Rectangular K.O.’s for Follow instructions 3 through 5 in A. Instructions