READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To
assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:1181
B1104 |
| Page 1 of 1 |
INSTALLATION PROCEDURE FOR: 1181WH, 1181CD, 1081WH, 1081CD
1181WH and 1181CD for use with 1104, 1104R, 1104IC and 1104ICR only. 1081WH and 1081CD for use with 1004, 1004R, 1004IC and 1004ICR only.
CAUTION: (RISK OF FIRE) FOR
OR WITHIN 3 INCHES OF ANY PART OF FIXTURE.
CAUTION: USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURER’S REFLECTOR
TRIMS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.
CAUTION: BEFORE INSTALLING REFLECTOR TO
OF
1
2GASKET INSTALLATION:
A.Align open side of gasket towards socket cup (figure A).
B.Pinch gasket and insert both edges under the reflector spring clip and align inner diameter to socket (figure B).
C.Push center of gasket until seated over socket and perimeter of gasket is just inside the socket cup (figure C).
D.Large internal diameter should fit over the lamp socket, small internal diameter sits on top of socket (figure D).
Figure A | Figure B | Figure C | Figure D |
CAUTION – DO NOT STRETCH SMALL INTERNAL DIAMETER OF GASKET OVER LAMP SOCKET.
THE GASKET MUST SIT ON TOP OF SOCKET TO PROVIDE SEAL TO LAMP.
3SNAP ON:
Insert gasketed socket cup into neck of reflector making sure spring clips of socket cup snap into slots of reflector (figure E).
Figure E
4PUSH UP:
Push reflector trim straight up into fixture housing until it is tight against ceiling (figure F).
Figure F
Note: To remove reflector trim, squeeze reflector spring clip from inside until the trim disengages. To retrieve socket cup, pull on one of the socket cup spring legs to disengage (figure G).
Replacement Gasket Available: Lightolier Catalog No. LFG356
Figure G
A COMPANY
631 Airport Road, Fall River, MA 02720