Lightolier 1101HLIE manual 195 390 585 780 SC = 60˚ 30˚, 186 60˚, 742, SC = 1.00 x

Page 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance Recessed CFL Downlighting  1101HLIE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 2 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

6 ¾" Aperture Horizontal Lensed, Compact Fluorescent, Performance Series,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Integrated Emergency, Reflector Trim

32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS

CANDLEPOWER SUMMARY

ZONAL LUMEN SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

0

195

390

585

780

SC = 1.1

60˚

30˚

Angle

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

0˚ CP

Zone

7770-10

76310-20

734

20-30

688

30-40

644

40-50

582

50-60

490

60-70

432

70-80

386

80-90

359

90-100

231100-110

113110-120

30120-130

7130-140

3140-150

3150-160

2160-170

Lumens

Zone

Lumens

%Lamp

%Fixt

 

Ceiling

 

80%

 

70%

50%

30%

 

72.01

0-30

545.79

24.8

47

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

198.72

0-40

818.08

37.2

70.4

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

275.06

0-60

1146.99

52.1

98.7

 

 

0

63

63

63

63

61

61

59

59

56

56

53

272.29

 

 

1

59

58

56

55

56

55

52

52

51

51

48

0-90

1162.29

52.8

100

 

 

232.89

 

 

2

56

52

50

48

52

49

50

46

48

45

43

90-120

0

0

0

 

Ratio

96.02

 

3

52

48

45

42

47

44

46

41

44

40

39

90-150

0

0

0

 

 

 

10.23

 

Cavity

4

49

44

40

37

43

40

42

37

41

36

35

90-180

0

0

0

 

2.99

 

5

45

40

36

33

39

36

38

33

37

33

31

 

 

0-180

0

0

0

 

 

2.08

 

Room

6

42

37

33

30

36

33

35

30

35

30

29

0

 

** Efficiency = 52.7%

**

 

7

40

34

30

27

33

30

33

27

32

27

26

0

 

 

 

8

37

31

28

25

31

27

30

25

30

25

24

 

 

 

 

 

 

0

 

 

 

 

 

 

9

35

29

25

23

29

25

28

23

28

23

22

0

 

 

 

 

 

10

33

27

23

21

27

23

26

21

26

21

20

0

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

0

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 35

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

CERTIFIED TEST REPORT NO. 3352FR COMPUTED BY LSI PROGRAM **TEST-LITE**

85

90

2170-180

0

32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS

0

186

60˚

3712

5571

742

1

– 90°

30˚

2

– 0°

 

SC = 1.00 x 1.02

CERTIFIED TEST REPORT NO. 3359FR COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

 

Ceiling

 

80%

 

70%

50%

30%

 

 

Zone

Lumens

%Lamp

%Fixt

 

 

 

Angle

0˚ CP

90˚ CP

Zone

Lumens

0-30

506.3

23

50.3

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

0

715

715

 

0-10

68.88

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

 

0-40

727.96

33.1

72.3

 

 

5

712

730

 

10-20

192.34

 

 

0

54

54

54

54

53

53

51

51

49

49

46

 

20-30

245.08

0-60

986.94

44.9

98

 

 

1

51

50

49

47

49

47

47

45

45

44

42

10

694

742

 

 

 

 

30-40

221.66

0-90

1007.01

45.8

100

 

 

2

48

46

43

41

45

41

43

40

42

39

38

15

652

701

 

 

Ratio

 

40-50

168.88

90-120

0

0

0

 

3

45

42

39

37

41

36

40

36

39

35

34

20

598

631

 

 

 

 

 

 

50-60

90.1

90-150

0

0

0

 

 

4

42

38

35

33

38

33

36

32

36

32

31

25

520

544

 

 

Cavity

 

60-70

14.8

90-180

0

0

0

 

5

40

35

32

29

34

29

34

29

33

29

28

30

440

437

 

 

35

365

330

 

70-80

3.09

0-180

1007.01

45.8

100

 

Room

6

37

32

29

27

32

27

31

26

30

26

25

 

80-90

2.18

 

7

35

30

27

24

29

24

29

24

28

24

23

40

299

244

 

 

 

 

 

 

 

 

90-100

0

 

 

 

 

 

 

 

8

33

28

24

22

27

24

22

27

22

26

21

45

242

198

 

 

 

** Efficiency = 45.8% **

 

 

 

 

100-110

0

 

 

 

 

 

9

31

26

23

20

25

20

25

20

25

20

19

50

185

159

 

 

 

 

 

 

 

110-120

0

 

 

 

 

 

 

10

29

24

21

19

24

19

23

19

23

19

18

55

105

94

 

 

 

 

 

 

 

60

42

41

 

120-130

0

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

 

130-140

0

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 33.0

 

 

 

65

9

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

140-150

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150-160

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

3

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

160-170

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

170-180

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32W TRIPLE TUBE LAMP, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS

0

CANDLEPOWER SUMMARY

ZONAL LUMEN SUMMARY

ZONAL LUMENS AND PERCENTAGES

COEFFICIENTS OF UTILIZATION

143

287

430

573

60˚

SC = 1.2

30˚

 

CERTIFIED TEST REPORT NO. 3351FR COMPUTED BY LSI PROGRAM **TEST-LITE**

Angle

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

0˚ CP 573 571 564 549 524 491 448 398 339 278 210 113 39

8

3

2

2

2

2

Zone

0-10

10-20

20-30

30-40

40-50

50-60

60-70

70-80

80-90

90-100

100-110

110-120

120-130

130-140

140-150

150-160

160-170

170-180

Lumens

54.19

153.56

223.16

245.6

211.31

105.76

13.51

2.57

2.22

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

Ceiling

 

80%

 

70%

50%

30%

 

Zone

Lumens

%Lamp

%Fixt

 

 

 

0-30

430.92

19.6

42.6

 

Wall

70

50

30

10

50

10

50

10

50

10

0

 

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

0-40

676.51

30.8

66.9

 

 

 

0

55

55

55

55

53

53

51

51

49

49

46

0-60

993.57

45.2

98.2

 

 

1

52

50

49

47

49

47

47

45

45

44

42

0-90

1011.87

46

100

 

Ratio

2

48

45

43

41

44

41

43

40

42

39

37

90-120

0

0

0

 

3

45

41

38

36

40

36

39

35

38

34

33

90-150

0

0

0

 

4

42

37

34

32

37

31

36

31

35

31

30

 

Cavity

90-180

0

0

0

 

5

39

34

31

28

34

28

33

28

32

28

26

0-180

1011.87

46

100

 

Room

6

36

31

28

25

31

25

30

25

29

25

24

 

7

34

29

25

23

28

23

28

23

27

22

21

 

 

** Efficiency = 46%

**

 

 

8

32

26

23

21

26

21

25

20

25

20

19

 

 

 

 

9

30

24

21

19

24

19

24

19

23

19

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

28

23

19

17

22

17

22

17

22

17

16

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 35.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

 

 

Type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • B0908

Lightolier is a Philips group brand

Image 2