ADDRESS SET

The address of the system keyboard can be set.

Press “ADDRESS SET” and the keyboard address input window will appear as shown below.

Enter the address by using the number keys and press the enter key. Press enter the “EXIT” ICON on lower left if you want to clear the window without entering the address.

The ADDRESS of the keyboard can be set as 0 ~ 32.

- ADDRESS “0” : STAND ALONE

-ADDRESS “1” : MASTER

-ADDRESS “2~32” : SLAVE

If you use a keyboard, it should be set to “0”.

If you use 2 or more keyboards, you should set one of them to “1” and oth- ers to other numbers between “2~32”. There can be errors in communica- tion if you set any of them to “0”.

RS-232 COMMUNICATION SETUP

GB-13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The default setup for the RS-232 communication of the keyboard is as follows.

-BAUD RATE : 4800

-DATA BIT : 8

-PARITY CHECK : NONE

-STOP BIT : 1

ADDRESS SET

Same as the address set of RS-485 COMMUNICATION.

BAUD RATE

The BAUD RATE of RS-232 communication can be set.

Press “BAUD RATE” and a pop-up window will appear as shown below.

BAUD RATE

The BAUD RATE of the RS-485 communication can be set. Press “BAUD RATE” and a pop-up window will appear as shown below.

RS-485 communication of the system keyboard supports Baud Rate as follows. 4800/ 9600/ 19200/ 38400

Among these 4 kinds of BAUD RATE, select one BAUD RATE.

DUPLEX

You can set the duplex mode of system keyboard.

Press “DUPLEX”, and then the following window pops up.

FULL DUPLEX / HALF DUPLEX

Select one of the two duplex. Press the exit icon on the lower left to finish RS-485 COMMUNICATION SETUP control and return to the KEYBOARD SETUP screen.

RS-232 communication of the system keyboard supports Baud Rate as follows.

600 / 1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600

Among these 8 kinds of BAUD RATE, select one BAUD RATE.

DATA BIT

The BAUD RATE of RS-232 communication can be set.

Press “DATA BIT” and a pop-up window will appear as shown below.

Choose one between 7 / 8.

Image 13
Contents System Keyboard GB-2 Important Safety InstructionsGeneral Facts ContentsInstallation Environment Setup InstallationGB-4 Checking Contents & Accessories Connecting withAdjusting System Keyboard Angle Fixing Power Cord Connecting RS-485 DeviceGB-6 Basic System Diagram of SSC-2000 Connecting PC by RS-232Connecting Other System Keyboard GB-7Log-in InstructionsCamera control GB-9 Preset DeleteMove to the connected device GB-10 Camera connection informationEnter the number of the connected DVR Enter the number of the connected MUXMUX control DVR controlCamera Menu DVR MenuKeyboard Setup Menu setupRS-485 Communication Setup Main MenuAddress SET RS-232 Communication SetupBaud Rate DuplexCheck Password Change PasswordRegister NEW Operater Parity CheckCamera Data Upload Camera Data DownloadGB-15 Operator Level System Information and SetupPassword in the screen of system log in is lost Product SpecificationGB-17 System keyboard communication is not worked
Related manuals
Manual 17 pages 33.18 Kb Manual 1 pages 36.24 Kb

SCC-101BP, SCC-101BP/TRK, SCC-100BP specifications

The Samsung SCC-100BP and SCC-101BP series are notable entries in the realm of security cameras, designed to meet the demands of diverse surveillance needs. These models combine advanced technology with ease of use, making them a preferred choice for both residential and commercial applications.

One of the standout features of the SCC-100BP is its high resolution. The camera produces clear, detailed images, allowing users to identify individuals and objects with precision. This enhanced clarity is essential for effective monitoring, particularly in low-light conditions. The SCC-101BP models build on this foundation, integrating additional functionalities that enhance their versatility in various environments.

Equipped with advanced image sensors, both the SCC-100BP and SCC-101BP series capture high-quality video in a range of lighting conditions. The cameras feature built-in infrared (IR) technology, enabling night vision capabilities. This feature ensures that the camera can record clear footage even in total darkness, providing around-the-clock surveillance and increasing security effectiveness.

Another important aspect of these cameras is their compact design. The SCC-100BP has a sleek profile that allows for easy installation in a variety of settings without being obtrusive. The SCC-101BP, with its slightly more robust form factor, is built for enhanced durability while maintaining aesthetic appeal. This factor is particularly important in commercial settings where aesthetics may influence customer perception.

The SCC-101BP/TRK model includes additional tracking capabilities. This technology allows the camera to automatically follow moving objects, ensuring that critical footage is captured without manual intervention. This feature is especially beneficial in high-traffic areas or locations that require continuous monitoring of activities.

Both series also support flexible integration with existing security systems. They are compatible with various recording devices and can be linked to centralized monitoring solutions. This interconnectivity is crucial for users looking to implement comprehensive security strategies.

In terms of user experience, the cameras are designed for straightforward operation. They come with adjustable settings for resolution, frame rates, and more, giving users the ability to customize the surveillance according to their specific needs.

In summary, the Samsung SCC-100BP and SCC-101BP series offer advanced features like high-resolution imaging, night vision, a compact design, and seamless integration. These characteristics make them a solid choice for enhancing security and surveillance capabilities across different environments.