Samsung AR12FSFTKWQXET, AR12FSFTKWQNET, AR12FSFTKWQXZE manual ErP InformationAC Product

Page 1

ErP Information(AC Product)

 

 

 

 

 

 

AR12FSFTKWQN / AR12FSFTKWQX

According to Commission Regulation (EU) No 206/2012

 

 

 

 

 

 

 

 

 

 

 

 

 

If function includes heating: Indicate the heating season the

 

Function (indicate if persent)

 

informaiont relates to. Indicated values should relate to one

 

 

heating season at a time. Include at least the heating season

 

 

 

 

 

 

 

 

 

 

 

 

 

 

'Average'

 

 

cooling

 

Y

 

Average

 

 

Y

heating

 

Y

 

Warmer

 

 

Y

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colder

 

 

N

 

 

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Design load

 

 

 

 

 

Seasonal efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Pdesignc

 

3,5

 

kW

cooling

SEER

 

5,6

 

-

heating/Average

Pdesignh

 

2,8

 

kW

heating/Average

SCOP/A

 

3,4

 

-

heating/Warmer

Pdesignh

 

2,8

 

kW

heating/Warmer

SCOP/W

 

4,0

 

-

heating/Colder

Pdesignh

 

-

 

kW

heating/Colder

SCOP/C

 

-

 

-

Declared capacity(*) for

cooling, at indoor temperature

 

 

 

Declared energy efficiency ratio(*), at indoor temperature

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Tj = 35 ℃

Pdc

 

3,5

 

kW

Tj = 35 ℃

EERd

 

3,0

 

-

Tj = 30 ℃

Pdc

 

2,6

 

kW

Tj = 30 ℃

EERd

 

4,5

 

-

Tj = 25 ℃

Pdc

 

1,6

 

kW

Tj = 25 ℃

EERd

 

6,8

 

-

Tj = 20 ℃

Pdc

 

1,2

 

kW

Tj = 20 ℃

EERd

 

9,7

 

-

Declared capacity(*) for

heating/Average season, at indoor

 

Declared coefficient of performance(*)/Average season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = - 7 ℃

Pdh

 

2,7

 

kW

Tj = -7

COPd

 

2,5

 

-

Tj = 2 ℃

Pdh

 

1,6

 

kW

Tj = 2 ℃

COPd

 

3,5

 

-

Tj = 7 ℃

Pdh

 

1,0

 

kW

Tj = 7 ℃

COPd

 

3,9

 

-

Tj = 12 ℃

Pdh

 

1,0

 

kW

Tj = 12 ℃

COPd

 

4,9

 

-

Tj = bivalent

Pdh

 

2,8

 

kW

Tj = bivalent

COPd

 

2,3

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

2,8

 

kW

Tj = operating limit

COPd

 

2,3

 

-

Declared capacity(*) for

heating/Warmer season, at indoor

 

Declared coefficient of performance(*)/Warmer season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = 2 ℃

Pdh

 

2,8

 

kW

Tj = 2 ℃

COPd

 

2,5

 

-

Tj = 7 ℃

Pdh

 

1,8

 

kW

Tj = 7 ℃

COPd

 

4,0

 

-

Tj = 12 ℃

Pdh

 

1,0

 

kW

Tj = 12 ℃

COPd

 

4,9

 

-

Tj = bivalent

Pdh

 

2,8

 

kW

Tj = bivalent

COPd

 

2,5

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

2,8

 

kW

Tj = operating limit

COPd

 

2,3

 

-

Declared capacity(*) for

heating/Colder season, at indoor

 

Declared coefficient of performance(*)/Colder season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = -7

Pdh

 

-

 

kW

Tj = -7

COPd

 

-

 

-

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Tj = -15

Pdh

 

-

 

kW

Tj = -15

COPd

 

-

 

-

Bivalent temperature

 

 

 

 

 

Operating limit temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heating/Average

Tbiv

 

-10

 

heating/Average

Tol

 

-10

 

heating/Warmer

Tbiv

 

2

 

heating/Warmer

Tol

 

-10

 

heating/Colder

Tbiv

 

-

 

heating/Colder

Tol

 

-

 

Cycling interval capacity

 

 

 

Cycling interval efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

for cooling

Pcycc

 

-

 

kW

for cooling

EERcyc

 

-

 

-

for heating

Pcych

 

-

 

kW

for heating

COPcyc

 

-

 

-

Degradation

 

 

 

 

 

Degradation

 

 

 

 

 

co-efficient

Cdc

 

0,25

 

kW

co-efficient

Cdh

 

0,25

 

-

cooling(**)

 

 

 

 

 

heating(**)

 

 

 

 

 

Electric power input in

power modes other than

 

 

 

Annual electricity consumption

 

 

 

 

'active mode'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off mode

POFF

 

0,0

 

kW

cooling

QCE

 

219

 

kWh/a

standby mode

PSB

 

0,0

 

kW

heating/Average

QHE

 

1153

 

kWh/a

thermostat-off mode

PTO

 

0,1

 

kW

heating/Warmer

QHE

 

970

 

kWh/a

crankcase heater

PCK

 

0,0

 

kW

heating/Colder

QHE

 

-

 

kWh/a

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity control (indicate one of three options)

 

 

 

Other items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

N

 

 

 

Sound power level

LWA

 

57,0/62,0

 

dB(A)

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

staged

N

 

 

 

Global warming

GWP

 

1975

 

kgCO2 eq.

 

 

 

potential

 

 

 

 

 

 

 

 

 

 

 

 

 

variable

Y

 

 

 

Rated air flow

-

 

660/1980

 

m3/h

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact details for

 

 

 

 

 

 

 

 

 

 

 

obtaining more

http://www.samsung.com

 

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

 

(*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of the unit' and 'declared EER/COP' of unit.

(**)If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.

Image 1
Contents According to Commission Regulation EU No 206/2012 ErP InformationAC Product
Related manuals
Manual 45 pages 3.43 Kb Manual 47 pages 32.01 Kb Manual 45 pages 23.12 Kb Manual 47 pages 49.79 Kb Manual 45 pages 45.25 Kb Manual 45 pages 732 b Manual 43 pages 53.57 Kb

AR12FSFTKWQNZE, AR12FSFTKWQXET, AR12FSFTKWQNET, AR12FSFTKWQXZE specifications

The Samsung AR09FSFTKWQNZE and AR12FSFTKWQNET represent a new standard in air conditioning technology, designed to deliver maximum comfort and efficiency. These models incorporate state-of-the-art features that cater to the needs of modern households.

One of the standout characteristics of the AR series is its advanced inverter technology. This feature allows the air conditioner to adjust its cooling output in real-time, providing consistent temperatures while consuming less energy. This results in lower electricity bills and reduced environmental impact, making it an eco-friendly choice for consumers.

Another remarkable aspect is the Turbo Cooling function, which ensures rapid cooling of spaces, achieving the desired temperature in a significantly shorter time. This is especially beneficial during hot summer days when immediate relief from heat is essential. Additionally, the models come equipped with a Good Sleep Mode, which optimizes the cooling process to ensure a comfortable sleeping environment by maintaining a steady temperature throughout the night.

The air purifying capabilities of the Samsung AR09FSFTKWQNZE and AR12FSFTKWQNET cannot be overlooked. Each unit features a multi-layered filtration system that effectively captures dust, allergens, and odors in the air, promoting a healthier indoor atmosphere. This technology is particularly advantageous for individuals with allergies or respiratory issues.

These air conditioners also prioritize user convenience through features such as Wi-Fi connectivity and Smart Control. Users can manage their cooling preferences remotely via a smartphone app, allowing for greater flexibility and ease of use. This integration with smart home systems enhances the overall user experience.

In terms of design, the Samsung AR series sports a sleek and modern aesthetic that can seamlessly blend into any interior decor. The easy-to-clean surfaces and discreet appearance further add to their appeal.

Overall, the Samsung AR09FSFTKWQNZE, AR12FSFTKWQNET, AR09FSFTKWQNET, and AR12FSFTKWQNZE air conditioners exemplify cutting-edge cooling technology. With their focus on energy efficiency, air purification, and user-friendly features, they represent an ideal choice for consumers seeking comfort, convenience, and environmental responsibility in their HVAC solutions. Whether for a small apartment or a large house, these models are designed to meet diverse cooling needs while enhancing the quality of indoor air.