Lightolier specifications Lytecaster Performance Recessed CFL Downlighting 2001L

Page 2
18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS

Lytecaster® Performance Recessed CFL Downlighting  2001L

Page of 2

50

60˚

100

150

1

200

30˚

SC = 1.6

CERTIFIED TEST REPORT NO. 3349FR COMPUTED BY LSI PROGRAM **TEST-LITE**

3 ¾" Aperture Vertical Wet Location, Compact Fluorescent, Performance Series, Reflector Trim

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

Angle

0˚ CP

 

Zone

Lumens

 

Zone

Lumens

%Lamp

%Fixt

 

Ceiling

 

80%

 

70%

50%

30%

 

0

129

 

 

0-10

13.37

 

0-30

139.25

11.6

38.1

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

5

135

 

10-20

46.72

 

0-40

232.59

19.4

63.6

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

10

150

 

20-30

79.16

 

0-60

353.98

29.5

96.8

 

 

0

36

36

36

36

35

35

34

34

32

32

30

15

165

 

30-40

93.34

 

0-90

365.87

30.5

100

 

 

1

34

33

32

31

32

31

31

30

30

29

27

20

173

 

40-50

79.65

 

90-120

0

0

0

 

Ratio

2

32

30

28

27

29

26

28

27

26

27

24

25

172

 

50-60

41.74

 

90-130

0

0

0

 

3

29

27

25

23

26

23

26

23

25

22

21

30

165

 

60-70

10.17

 

90-150

0

0

0

 

Cavity

4

27

24

22

20

24

20

23

20

22

20

19

35

150

 

70-80

1.58

 

90-180

0

0

0

 

5

25

22

20

18

22

18

21

18

20

17

17

40

131

 

80-90

.14

 

0-180

365.87

30.5

100

 

Room

6

24

20

18

16

20

16

19

16

19

16

15

45

104

 

90

-100

0

 

 

** Efficiency = 30.5%**

7

22

18

16

14

18

14

18

14

17

14

13

50

74

 

100-110

0

 

 

 

 

 

 

 

8

20

17

14

13

17

13

16

13

16

13

12

55

46

 

110-120

0

 

 

 

 

 

 

 

9

19

15

13

12

15

12

15

11

15

11

11

60

24

 

120

-130

0

 

 

 

 

 

 

10

18

14

12

11

14

10

14

10

14

10

10

65

8

 

130-140

0

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

70

3

 

140

-150

0

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 22.0

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

150

-160

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

1

 

160-170

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

0

 

170

-180

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS

50

100

150

200

60˚

1

30˚

SC = 1.4

CERTIFIED TEST REPORT NO. 3348FR COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

Angle

0˚ CP

 

Zone

Lumens

 

Zone

Lumens

%Lamp

%Fixt

 

Ceiling

 

80%

 

70%

50%

30%

 

0

151

 

 

0-10

14.54

 

0-30

131.6

11

37

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

5

152

 

10-20

44.62

 

0-40

217.11

18.1

61.1

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

10

154

 

20-30

72.45

 

0-60

333.76

27.8

93.9

 

 

0

35

35

35

35

34

34

33

33

31

31

30

15

157

 

30-40

85.51

 

0-90

355.26

29.6

100

 

 

1

33

32

31

30

31

30

29

28

27

27

26

20

159

 

40-50

73.84

 

90-120

0

0

0

 

Ratio

2

31

29

27

26

28

25

27

25

26

24

23

25

158

 

50-60

42.8

 

90-130

0

0

0

 

3

28

26

24

22

25

22

24

22

24

21

20

30

151

 

60-70

16.63

 

90-150

0

0

0

 

Cavity

4

26

23

21

19

23

19

22

19

21

19

18

35

138

 

70-80

4.73

 

90-180

0

0

0

 

5

24

21

19

17

21

17

20

17

20

17

16

40

119

 

80-90

.14

 

0-180

355.26

29.6

100

 

Room

6

23

19

17

15

19

15

18

15

18

15

14

45

97

 

90

-100

0

 

 

** Efficiency = 29.6%**

 

 

7

21

17

15

13

17

13

17

13

16

13

13

50

71

 

100-110

0

 

 

 

 

 

 

 

8

20

16

14

12

16

12

13

15

13

12

11

55

47

 

110-120

0

 

 

 

 

 

 

 

9

18

15

12

11

15

11

14

11

14

11

10

60

28

 

120

-130

0

 

 

 

 

 

 

10

17

14

11

10

13

10

13

10

13

10

9

65

16

 

130-140

0

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

70

9

 

140

-150

0

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 22.0

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

150

-160

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

1

 

160-170

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

0

 

170

-180

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS

50

100

150

200

60˚

1

30˚

SC = 1.1

CERTIFIED TEST REPORT NO. 3350FR COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER SUMMARY

 

ZONAL LUMEN SUMMARY

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

Angle

0˚ CP

 

Zone

Lumens

 

Zone

Lumens

%Lamp

%Fixt

 

Ceiling

 

80%

 

70%

50%

30%

 

0

151

 

 

0-10

14.23

 

0-30

111.65

9.3

35.8

 

Wall

 

70

50

30

10

50

10

50

10

50

10

0

5

150

 

10-20

39.88

 

0-40

175.81

14.7

56.4

 

RCR

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

10

147

 

20-30

57.54

 

0-60

279.09

23.3

89.6

 

 

0

31

31

31

31

30

30

29

29

28

28

26

15

142

 

30-40

64.16

 

0-90

311.48

26

100

 

 

1

29

28

27

26

27

26

26

25

25

24

23

20

134

 

40-50

58.87

 

90-120

0

0

0

 

Ratio

2

27

25

23

22

24

22

23

21

23

21

20

25

125

 

50-60

44.41

 

90-130

0

0

0

 

3

24

22

20

19

22

19

21

18

20

18

17

30

115

 

60-70

25.17

 

90-150

0

0

0

 

Cavity

4

23

20

18

16

20

16

19

16

18

16

15

35

103

 

70-80

7.09

 

90-180

0

0

0

 

5

21

18

16

14

18

14

17

14

17

14

13

40

90

 

80-90

.14

 

0-180

311.48

26

100

 

Room

6

19

6

14

13

16

13

16

12

15

12

12

45

76

 

90

-100

0

 

 

** Efficiency = 26%**

 

 

7

18

15

13

11

15

11

14

11

14

11

11

50

63

 

100-110

0

 

 

 

 

 

 

 

8

17

14

12

10

13

10

13

10

13

10

9

55

50

 

110-120

0

 

 

 

 

 

 

 

9

16

13

11

9

12

9

12

9

12

9

9

60

37

 

120

-130

0

 

 

 

 

 

 

10

15

12

10

8

12

8

11

8

11

8

8

65

25

 

130-140

0

 

 

 

 

 

 

Determined In Accordance With Current IES Published Procedures

70

15

 

140

-150

0

 

 

 

 

 

 

 

 

 

 

Luminaire Input Watts = 22.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

6

 

150

-160

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

1

 

160-170

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

0

 

170

-180

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2007 Genlyte Group LLC • C1007

Image 2
Contents Labels FeaturesCompatible Frame-In Kits Series Reflector Trims Lytecaster Performance Recessed CFL Downlighting 2001L

2001L specifications

The Lightolier 2001L is a modern lighting solution that exemplifies both aesthetic appeal and functional efficiency. Designed with flexibility in mind, this versatile fixture seamlessly adapts to a variety of settings, making it a preferred choice for both residential and commercial spaces.

At the heart of the Lightolier 2001L is its innovative LED technology. LEDs are renowned for their energy efficiency, longevity, and minimal heat production. This smart implementation not only reduces energy costs but also contributes to a lower carbon footprint, aligning with eco-friendly practices. The fixture offers impressive luminous efficacy, ensuring that each space is illuminated uniformly without harsh glares.

A standout feature of the 2001L is its adjustable beam angle. Users can manipulate the light direction, which allows for customized lighting arrangements according to different needs and preferences. This flexibility is particularly beneficial in environments like galleries or retail spaces, where targeted lighting helps in enhancing the displayed items and creating a desirable ambiance.

The design of the Lightolier 2001L combines function with style. Available in various finishes and colors, it complements a wide range of interior décors. Its sleek and unobtrusive design means it can blend seamlessly into any design scheme, from contemporary to classic.

Ease of installation is another significant advantage of the 2001L. Designed to accommodate a range of mounting options, including surface and recessed installations, the fixture allows for straightforward integration into existing designs without extensive renovations. This feature proves advantageous for both professionals and DIY enthusiasts.

In terms of durability, the Lightolier 2001L is constructed from high-quality materials that ensure reliability over time. The fixture is resistant to wear and tear, supporting its extended lifespan.

Moreover, it's designed with smart technology capabilities, allowing integration with various home automation systems. This feature contributes to convenience and enhances energy management by providing users with control over their lighting preferences through smartphones or voice-activated devices.

Overall, the Lightolier 2001L stands out as a sophisticated and reliable lighting option. With its focus on adaptability, energy efficiency, and stylish design, it is an exemplary choice for anyone seeking to elevate their space with modern illumination solutions.