ErP Information(AC Product) |
|
|
|
|
|
| AR09FSFPKGMN / AR09FSFPKGMX | ||||
According to Commission Regulation (EU) No 206/2012 |
|
|
|
|
|
|
| ||||
|
|
|
|
|
| If function includes heating: Indicate the heating season the | |||||
| Function (indicate if persent) |
| informaiont relates to. Indicated values should relate to one | ||||||||
|
| heating season at a time. Include at least the heating season | |||||||||
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| 'Average' |
|
| |
cooling |
| Y |
| Average |
|
| Y | ||||
heating |
| Y |
| Warmer |
|
| Y | ||||
|
| (if designated) |
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| Colder |
|
| N | ||
|
|
|
|
|
| (if designated) |
|
| |||
|
|
|
|
|
|
|
|
|
| ||
Item | symbol |
| value |
| unit | Item | symbol |
| value |
| unit |
Design load |
|
|
|
|
| Seasonal efficiency |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Cooling | Pdesignc |
| 2,5 |
| kW | cooling | SEER |
| 5,6 |
| - |
heating/Average | Pdesignh |
| 2,5 |
| kW | heating/Average | SCOP/A |
| 3,4 |
| - |
heating/Warmer | Pdesignh |
| 2,5 |
| kW | heating/Warmer | SCOP/W |
| 4,0 |
| - |
heating/Colder | Pdesignh |
| - |
| kW | heating/Colder | SCOP/C |
| - |
| - |
Declared capacity(*) for | cooling, at indoor temperature |
|
|
| Declared energy efficiency ratio(*), at indoor temperature |
|
| ||||
27(19) ℃ and outdoor temperature Tj |
|
|
| 27(19) ℃ and outdoor temperature Tj |
|
|
|
| |||
Item | symbol |
| value |
| unit | Item | symbol |
| value |
| unit |
Tj = 35 ℃ | Pdc |
| 2,5 |
| kW | Tj = 35 ℃ | EERd |
| 3,5 |
| - |
Tj = 30 ℃ | Pdc |
| 1,9 |
| kW | Tj = 30 ℃ | EERd |
| 4,9 |
| - |
Tj = 25 ℃ | Pdc |
| 1,2 |
| kW | Tj = 25 ℃ | EERd |
| 7,0 |
| - |
Tj = 20 ℃ | Pdc |
| 1,2 |
| kW | Tj = 20 ℃ | EERd |
| 9,0 |
| - |
Declared capacity(*) for | heating/Average season, at indoor |
| Declared coefficient of performance(*)/Average season, |
|
| ||||||
temperature 20 ℃ and outdoor temperature Tj |
|
|
| at indoor temperature 20 ℃ and outdoor temperature Tj |
|
| |||||
Tj = - 7 ℃ | Pdh |
| 2,3 |
| kW | Tj = | COPd |
| 2,5 |
| - |
Tj = 2 ℃ | Pdh |
| 1,4 |
| kW | Tj = 2 ℃ | COPd |
| 3,4 |
| - |
Tj = 7 ℃ | Pdh |
| 0,9 |
| kW | Tj = 7 ℃ | COPd |
| 4,1 |
| - |
Tj = 12 ℃ | Pdh |
| 1,0 |
| kW | Tj = 12 ℃ | COPd |
| 4,9 |
| - |
Tj = bivalent | Pdh |
| 2,5 |
| kW | Tj = bivalent | COPd |
| 2,4 |
| - |
temperature |
|
| temperature |
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||
Tj = operating limit | Pdh |
| 2,5 |
| kW | Tj = operating limit | COPd |
| 2,4 |
| - |
Declared capacity(*) for | heating/Warmer season, at indoor |
| Declared coefficient of performance(*)/Warmer season, |
|
| ||||||
temperature 20 ℃ and outdoor temperature Tj |
|
|
| at indoor temperature 20 ℃ and outdoor temperature Tj |
|
| |||||
Tj = 2 ℃ | Pdh |
| 2,5 |
| kW | Tj = 2 ℃ | COPd |
| 2,8 |
| - |
Tj = 7 ℃ | Pdh |
| 1,5 |
| kW | Tj = 7 ℃ | COPd |
| 4,5 |
| - |
Tj = 12 ℃ | Pdh |
| 1,0 |
| kW | Tj = 12 ℃ | COPd |
| 5,1 |
| - |
Tj = bivalent | Pdh |
| 2,5 |
| kW | Tj = bivalent | COPd |
| 2,8 |
| - |
temperature |
|
| temperature |
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||
Tj = operating limit | Pdh |
| 2,5 |
| kW | Tj = operating limit | COPd |
| 2,4 |
| - |
Declared capacity(*) for | heating/Colder season, at indoor |
| Declared coefficient of performance(*)/Colder season, |
|
| ||||||
temperature 20 ℃ and outdoor temperature Tj |
|
|
| at indoor temperature 20 ℃ and outdoor temperature Tj |
|
| |||||
Tj = | Pdh |
| - |
| kW | Tj = | COPd |
| - |
| - |
Tj = 2 ℃ | Pdh |
| - |
| kW | Tj = 2 ℃ | COPd |
| - |
| - |
Tj = 7 ℃ | Pdh |
| - |
| kW | Tj = 7 ℃ | COPd |
| - |
| - |
Tj = 12 ℃ | Pdh |
| - |
| kW | Tj = 12 ℃ | COPd |
| - |
| - |
Tj = bivalent | Pdh |
| - |
| kW | Tj = bivalent | COPd |
| - |
| - |
temperature |
|
| temperature |
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||
Tj = operating limit | Pdh |
| - |
| kW | Tj = operating limit | COPd |
| - |
| - |
Tj = | Pdh |
| - |
| kW | Tj = | COPd |
| - |
| - |
Bivalent temperature |
|
|
|
|
| Operating limit temperature |
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
heating/Average | Tbiv |
|
| ℃ | heating/Average | Tol |
|
| ℃ | ||
heating/Warmer | Tbiv |
| 2 |
| ℃ | heating/Warmer | Tol |
|
| ℃ | |
heating/Colder | Tbiv |
| - |
| ℃ | heating/Colder | Tol |
| - |
| ℃ |
Cycling interval capacity |
|
|
| Cycling interval efficiency |
|
|
|
| |||
|
|
|
|
|
|
|
|
| |||
for cooling | Pcycc |
| - |
| kW | for cooling | EERcyc |
| - |
| - |
for heating | Pcych |
| - |
| kW | for heating | COPcyc |
| - |
| - |
Degradation |
|
|
|
|
| Degradation |
|
|
|
|
|
Cdc |
| 0,25 |
| kW | Cdh |
| 0,25 |
| - | ||
cooling(**) |
|
|
|
|
| heating(**) |
|
|
|
|
|
Electric power input in | power modes other than |
|
|
| Annual electricity consumption |
|
|
|
| ||
'active mode' |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
off mode | POFF |
| 0,0 |
| kW | cooling | QCE |
| 156 |
| kWh/a |
standby mode | PSB |
| 0,0 |
| kW | heating/Average | QHE |
| 1029 |
| kWh/a |
PTO |
| 0,1 |
| kW | heating/Warmer | QHE |
| 875 |
| kWh/a | |
crankcase heater | PCK |
| 0,0 |
| kW | heating/Colder | QHE |
| - |
| kWh/a |
mode |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| |
Capacity control (indicate one of three options) |
|
|
| Other items |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
fixed | N |
|
|
| Sound power level | LWA |
| 54,0/59,0 |
| dB(A) | |
|
|
| (indoor/outdoor) |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |
staged | N |
|
|
| Global warming | GWP |
| 1975 |
| kgCO2 eq. | |
|
|
| potential |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |
variable | Y |
|
|
| Rated air flow | - |
| 600/1920 |
| m3/h | |
|
|
| (indoor/outdoor) |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |
Contact details for |
|
|
|
|
|
|
|
|
|
|
|
obtaining more | http://www.samsung.com |
|
|
|
|
|
|
|
|
| |
information |
|
|
|
|
|
|
|
|
|
|
|
(*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of the unit' and 'declared EER/COP' of unit.
(**)If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.