Samsung AR12FSFPKGMNET, AR12FSFPKGMXET, AR12FSFPKGMNZE manual ErP InformationAC Product

Page 1

ErP Information(AC Product)

 

 

 

 

 

 

AR12FSFPKGMN / AR12FSFPKGMX

According to Commission Regulation (EU) No 206/2012

 

 

 

 

 

 

 

 

 

 

 

 

 

If function includes heating: Indicate the heating season the

 

Function (indicate if persent)

 

informaiont relates to. Indicated values should relate to one

 

 

heating season at a time. Include at least the heating season

 

 

 

 

 

 

 

 

 

 

 

 

 

 

'Average'

 

 

cooling

 

Y

 

Average

 

 

Y

heating

 

Y

 

Warmer

 

 

Y

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colder

 

 

N

 

 

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Design load

 

 

 

 

 

Seasonal efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Pdesignc

 

3,5

 

kW

cooling

SEER

 

5,6

 

-

heating/Average

Pdesignh

 

2,8

 

kW

heating/Average

SCOP/A

 

3,4

 

-

heating/Warmer

Pdesignh

 

2,8

 

kW

heating/Warmer

SCOP/W

 

4,0

 

-

heating/Colder

Pdesignh

 

-

 

kW

heating/Colder

SCOP/C

 

-

 

-

Declared capacity(*) for

cooling, at indoor temperature

 

 

 

Declared energy efficiency ratio(*), at indoor temperature

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Tj = 35 ℃

Pdc

 

3,5

 

kW

Tj = 35 ℃

EERd

 

3,0

 

-

Tj = 30 ℃

Pdc

 

2,6

 

kW

Tj = 30 ℃

EERd

 

4,5

 

-

Tj = 25 ℃

Pdc

 

1,6

 

kW

Tj = 25 ℃

EERd

 

6,8

 

-

Tj = 20 ℃

Pdc

 

1,2

 

kW

Tj = 20 ℃

EERd

 

9,7

 

-

Declared capacity(*) for

heating/Average season, at indoor

 

Declared coefficient of performance(*)/Average season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = - 7 ℃

Pdh

 

2,7

 

kW

Tj = -7

COPd

 

2,5

 

-

Tj = 2 ℃

Pdh

 

1,6

 

kW

Tj = 2 ℃

COPd

 

3,5

 

-

Tj = 7 ℃

Pdh

 

1,0

 

kW

Tj = 7 ℃

COPd

 

3,9

 

-

Tj = 12 ℃

Pdh

 

1,0

 

kW

Tj = 12 ℃

COPd

 

4,9

 

-

Tj = bivalent

Pdh

 

2,8

 

kW

Tj = bivalent

COPd

 

2,3

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

2,8

 

kW

Tj = operating limit

COPd

 

2,3

 

-

Declared capacity(*) for

heating/Warmer season, at indoor

 

Declared coefficient of performance(*)/Warmer season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = 2 ℃

Pdh

 

2,8

 

kW

Tj = 2 ℃

COPd

 

2,5

 

-

Tj = 7 ℃

Pdh

 

1,8

 

kW

Tj = 7 ℃

COPd

 

4,0

 

-

Tj = 12 ℃

Pdh

 

1,0

 

kW

Tj = 12 ℃

COPd

 

4,9

 

-

Tj = bivalent

Pdh

 

2,8

 

kW

Tj = bivalent

COPd

 

2,5

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

2,8

 

kW

Tj = operating limit

COPd

 

2,3

 

-

Declared capacity(*) for

heating/Colder season, at indoor

 

Declared coefficient of performance(*)/Colder season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = -7

Pdh

 

-

 

kW

Tj = -7

COPd

 

-

 

-

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Tj = -15

Pdh

 

-

 

kW

Tj = -15

COPd

 

-

 

-

Bivalent temperature

 

 

 

 

 

Operating limit temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heating/Average

Tbiv

 

-10

 

heating/Average

Tol

 

-10

 

heating/Warmer

Tbiv

 

2

 

heating/Warmer

Tol

 

-10

 

heating/Colder

Tbiv

 

-

 

heating/Colder

Tol

 

-

 

Cycling interval capacity

 

 

 

Cycling interval efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

for cooling

Pcycc

 

-

 

kW

for cooling

EERcyc

 

-

 

-

for heating

Pcych

 

-

 

kW

for heating

COPcyc

 

-

 

-

Degradation

 

 

 

 

 

Degradation

 

 

 

 

 

co-efficient

Cdc

 

0,25

 

kW

co-efficient

Cdh

 

0,25

 

-

cooling(**)

 

 

 

 

 

heating(**)

 

 

 

 

 

Electric power input in

power modes other than

 

 

 

Annual electricity consumption

 

 

 

 

'active mode'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off mode

POFF

 

0,0

 

kW

cooling

QCE

 

219

 

kWh/a

standby mode

PSB

 

0,0

 

kW

heating/Average

QHE

 

1153

 

kWh/a

thermostat-off mode

PTO

 

0,1

 

kW

heating/Warmer

QHE

 

970

 

kWh/a

crankcase heater

PCK

 

0,0

 

kW

heating/Colder

QHE

 

-

 

kWh/a

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity control (indicate one of three options)

 

 

 

Other items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

N

 

 

 

Sound power level

LWA

 

56,0/62,0

 

dB(A)

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

staged

N

 

 

 

Global warming

GWP

 

1975

 

kgCO2 eq.

 

 

 

potential

 

 

 

 

 

 

 

 

 

 

 

 

 

variable

Y

 

 

 

Rated air flow

-

 

660/1980

 

m3/h

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact details for

 

 

 

 

 

 

 

 

 

 

 

obtaining more

http://www.samsung.com

 

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

 

(*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of the unit' and 'declared EER/COP' of unit.

(**)If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.

Image 1
Contents According to Commission Regulation EU No 206/2012 ErP InformationAC Product
Related manuals
Manual 47 pages 43.03 Kb Manual 46 pages 39.71 Kb Manual 45 pages 27.27 Kb Manual 45 pages 23.86 Kb Manual 1 pages 26.59 Kb Manual 45 pages 14.41 Kb Manual 45 pages 15.07 Kb Manual 45 pages 25.41 Kb

AR12FSFPKGMXET, AR12FSFPKGMNZE, AR12FSFPKGMXZE, AR12FSFPKGMNET specifications

The Samsung AR12FSFPKGMNET, AR12FSFPKGMXZE, AR12FSFPKGMNZE, and AR12FSFPKGMXET are part of Samsung's cutting-edge line of air conditioners designed to offer efficient cooling and heating solutions for modern living spaces. These models are well-known for their innovative technologies, sleek designs, and energy-efficient performance, making them ideal for residential and commercial applications.

One of the standout features of these units is the Digital Inverter technology, which significantly reduces energy consumption compared to conventional models. By adjusting the compressor speed according to the cooling demand, the Digital Inverter maintains a consistent temperature while minimizing energy use, leading to lower utility bills. This technology also helps in reducing noise levels, providing you with a peaceful indoor environment.

In addition to energy efficiency, these air conditioners incorporate Samsung's unique Tri-Care Filter system. This advanced filtration technology effectively removes dust, allergens, and harmful particles from the indoor air, ensuring a healthier living space. The filters are easy to clean and can be accessed conveniently, promoting better maintenance practices.

Another important characteristic of the Samsung AR series is the Fast Cooling mode. This function allows the air conditioner to rapidly cool the room during hot weather, providing swift relief from heat. The powerful mode is particularly beneficial during the sweltering summer months when immediate cooling is essential.

The Smart Control feature is another significant innovation found in these models. Users can effortlessly control their air conditioners through a smartphone app, providing convenience and flexibility. With Smart Control, you can adjust temperatures, set timers, and monitor energy consumption from anywhere, making it easy to manage your indoor climate remotely.

Additionally, the design of the AR12FSFPKGMNET, AR12FSFPKGMXZE, AR12FSFPKGMNZE, and AR12FSFPKGMXET models is sleek and modern, allowing them to blend seamlessly into any interior decor. The compact size and subtle styling ensure a good fit for various room sizes, enhancing the aesthetic of the space while providing outstanding performance.

In conclusion, the Samsung AR12FSFPKGMNET, AR12FSFPKGMXZE, AR12FSFPKGMNZE, and AR12FSFPKGMXET air conditioners embody a perfect blend of advanced technology, energy efficiency, and user-friendly features, making them a top choice for consumers seeking reliable and stylish cooling solutions.