Samsung AR24FSFPDGMNEU, AR24FSFPDGMXEU manual ErP InformationAC Product

Page 1

ErP Information(AC Product)

 

 

 

 

 

 

AR24FSFPESNN / AR24FSFPESNX

According to Commission Regulation (EU) No 206/2012

 

 

 

 

 

 

 

 

 

 

 

 

 

If function includes heating: Indicate the heating season the

 

Function (indicate if persent)

 

informaiont relates to. Indicated values should relate to one

 

 

heating season at a time. Include at least the heating season

 

 

 

 

 

 

 

 

 

 

 

 

 

 

'Average'

 

 

cooling

 

Y

 

Average

 

 

Y

heating

 

Y

 

Warmer

 

 

N

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colder

 

 

N

 

 

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Design load

 

 

 

 

 

Seasonal efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Pdesignc

 

6,8

 

kW

cooling

SEER

 

6,1

 

-

heating/Average

Pdesignh

 

5,6

 

kW

heating/Average

SCOP/A

 

3,8

 

-

heating/Warmer

Pdesignh

 

-

 

kW

heating/Warmer

SCOP/W

 

-

 

-

heating/Colder

Pdesignh

 

-

 

kW

heating/Colder

SCOP/C

 

-

 

-

Declared capacity(*) for

cooling, at indoor temperature

 

 

 

Declared energy efficiency ratio(*), at indoor temperature

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Tj = 35 ℃

Pdc

 

6,8

 

kW

Tj = 35 ℃

EERd

 

2,90

 

-

Tj = 30 ℃

Pdc

 

5,3

 

kW

Tj = 30 ℃

EERd

 

4,70

 

-

Tj = 25 ℃

Pdc

 

3,3

 

kW

Tj = 25 ℃

EERd

 

7,1

 

-

Tj = 20 ℃

Pdc

 

1,9

 

kW

Tj = 20 ℃

EERd

 

10,5

 

-

Declared capacity(*) for

heating/Average season, at indoor

 

Declared coefficient of performance(*)/Average season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = - 7 ℃

Pdh

 

5,3

 

kW

Tj = -7

COPd

 

2,6

 

-

Tj = 2 ℃

Pdh

 

3,0

 

kW

Tj = 2 ℃

COPd

 

3,9

 

-

Tj = 7 ℃

Pdh

 

2,0

 

kW

Tj = 7 ℃

COPd

 

4,5

 

-

Tj = 12 ℃

Pdh

 

1,6

 

kW

Tj = 12 ℃

COPd

 

5,2

 

-

Tj = bivalent

Pdh

 

5,6

 

kW

Tj = bivalent

COPd

 

2,3

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

5,6

 

kW

Tj = operating limit

COPd

 

2,3

 

-

Declared capacity(*) for

heating/Warmer season, at indoor

 

Declared coefficient of performance(*)/Warmer season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Declared capacity(*) for

heating/Colder season, at indoor

 

Declared coefficient of performance(*)/Colder season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = -7

Pdh

 

-

 

kW

Tj = -7

COPd

 

-

 

-

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Tj = -15

Pdh

 

-

 

kW

Tj = -15

COPd

 

-

 

-

Bivalent temperature

 

 

 

 

 

Operating limit temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heating/Average

Tbiv

 

-10

 

heating/Average

Tol

 

-10

 

heating/Warmer

Tbiv

 

-

 

heating/Warmer

Tol

 

-

 

heating/Colder

Tbiv

 

-

 

heating/Colder

Tol

 

-

 

Cycling interval capacity

 

 

 

Cycling interval efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

for cooling

Pcycc

 

-

 

kW

for cooling

EERcyc

 

-

 

-

for heating

Pcych

 

-

 

kW

for heating

COPcyc

 

-

 

-

Degradation

 

 

 

 

 

Degradation

 

 

 

 

 

co-efficient

Cdc

 

0,25

 

kW

co-efficient

Cdh

 

0,25

 

-

cooling(**)

 

 

 

 

 

heating(**)

 

 

 

 

 

Electric power input in

power modes other than

 

 

 

Annual electricity consumption

 

 

 

 

'active mode'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off mode

POFF

 

0,0

 

kW

cooling

QCE

 

390

 

kWh/a

standby mode

PSB

 

0,0

 

kW

heating/Average

QHE

 

2063

 

kWh/a

thermostat-off mode

PTO

 

0,0

 

kW

heating/Warmer

QHE

 

-

 

kWh/a

crankcase heater

PCK

 

0,0

 

kW

heating/Colder

QHE

 

-

 

kWh/a

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity control (indicate one of three options)

 

 

 

Other items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

N

 

 

 

Sound power level

LWA

 

62,0/67,0

 

dB(A)

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

staged

N

 

 

 

Global warming

GWP

 

1975

 

kgCO2 eq.

 

 

 

potential

 

 

 

 

 

 

 

 

 

 

 

 

 

variable

Y

 

 

 

Rated air flow

-

 

1020/2400

 

m3/h

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact details for

 

 

 

 

 

 

 

 

 

 

 

obtaining more

http://www.samsung.com

 

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

 

(*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of the unit' and 'declared EER/COP' of unit.

(**)If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.

Image 1
Contents According to Commission Regulation EU No 206/2012 ErP InformationAC Product
Related manuals
Manual 25 pages 35.95 Kb Manual 25 pages 20.06 Kb Manual 25 pages 13.96 Kb Manual 25 pages 6.98 Kb Manual 27 pages 22.46 Kb Manual 25 pages 59.59 Kb Manual 25 pages 21 Kb Manual 26 pages 19.38 Kb Manual 25 pages 49.95 Kb Manual 1 pages 26.59 Kb Manual 14 pages 18.44 Kb

AR24FSFPDGMNEU, AR24FSFPDGMXEU specifications

The Samsung AR18FSFPDGMNEU and AR24FSFPDGMNEU are advanced air conditioning units that embody efficiency, comfort, and cutting-edge technology. Designed to cater to both residential and commercial spaces, these models stand out for their reliable performance and energy-saving capabilities.

One of the primary features of the AR18FSFPDGMNEU and AR24FSFPDGMNEU is their impressive cooling capacity. The AR18 model delivers 1.5 ton cooling output while the AR24 offers 2 ton cooling. This makes them suitable for medium to larger-sized rooms, ensuring optimal climate control even during the hottest days.

Both models are equipped with Samsung's Digital Inverter Technology, which adjusts the compressor speed to maintain the desired temperature without constant on-off cycles. This feature not only boosts energy efficiency but also significantly reduces power consumption, resulting in lower electricity bills and a smaller carbon footprint.

In terms of air quality, the AR18FSFPDGMNEU and AR24FSFPDGMNEU come with Samsung's advanced filtration system. This ensures that the air circulating in your space is clean and free from allergens, dust, and other harmful particles. The technology includes a removable and washable filter, making maintenance hassle-free and ensuring the longevity of the unit.

Another highlight is the "Fast Cooling" feature, which enables the units to cool the space quickly by optimizing the airflow and increasing the cooling speed. This is ideal for those hot summer days when you need immediate relief from the heat.

Furthermore, these air conditioners also incorporate a Smart Wi-Fi feature that allows users to manage settings remotely through a smartphone app. This convenience means that you can adjust temperatures, set timers, and check energy consumption even when you're not at home.

The design of the AR18FSFPDGMNEU and AR24FSFPDGMNEU is sleek and modern, ensuring that they blend seamlessly with any interior décor. Their quiet operation is an additional advantage, making them suitable for bedrooms, offices, and living spaces where noise can be a concern.

In summary, the Samsung AR18FSFPDGMNEU and AR24FSFPDGMNEU air conditioning units bring together energy efficiency, advanced cooling technologies, and air quality improvements, making them exceptional choices for consumers looking to enhance their indoor climate.